An evaluation of fluid distribution at the implant site during implant placement by using a computational fluid dynamics model

被引:2
|
作者
Hu, Shanshan [1 ]
Duan, Lunliang [2 ]
Wan, Qianbing [3 ]
Wang, Jian [3 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, State Key Lab Oral Dis, Chengdu, Sichuan, Peoples R China
[2] Southwest Jiaotong Univ, Dept Bridge Engn, Chengdu, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp Stomatol, Dept Prosthodont, 14,Sect 3,South Peoples Rd, Chengdu 610041, Sichuan, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 122卷 / 02期
基金
中国国家自然科学基金;
关键词
TEMPERATURE RISE; HEAT-PRODUCTION; IN-VITRO; BONE TEMPERATURE; THERMAL-CHANGES; IRRIGANT FLOW; DRILL SPEED; OSTEOTOMIES; GENERATION; PARAMETERS;
D O I
10.1016/j.prosdent.2018.12.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Heat reduction during implant site preparation is critical. However, studies that assess fluid distribution at the implant site by using saline irrigation as the cooling method during osteotomies are lacking. Purpose: The purpose of this study was to evaluate the effect of various parameters on fluid distribution at the implant site by using a computational fluid dynamics numerical model and thus predict the cooling effect at the drill site. Material and methods: The computational fluid dynamics code Flow-3D was adopted to simulate implant site preparation. A 10-mm-deep implant site was prepared by using a 2.2-mm pilot drill, with 4 degrees C saline sprayed onto the drill from an external injection hole. Different drilling procedures were performed with irrigation volumes of 20, 40, 60, and 80 mL/min at various drill speeds (600, 800, 1000, 1200 rpm) and feed rates (0.5, 1.0, 1.5, 2.0 mm/s), and the fluid distribution under various circumstances was respectively investigated and compared. Data were analyzed by using 1-way ANOVA or the Friedman test according to the normality of the data distribution (P>.05). Results: Below the irrigation volume of 60 mL/min, the saline inside the implant site increased with the irrigation volume (P<.001), but further increase in irrigation volume to 80 mL/min had no significant influence on the fluid distribution (P>.05). The obtained fluid had an inverse relationship with the drill speed under the irrigation volumes 20 and 40 mL/min (P<.001), and deeper areas received less cooling under 20 mL/min (P<.001). However, no significant differences were observed under 60 and 80 mL/min (P>.05). In addition, the variation of feed rate had no significant effect on the mean fluid fraction for all the tested groups (P>.05). Conclusion: The fluid distribution at the implant site could be affected by the irrigation volume and drill speed but was not correlated with the feed rate.
引用
收藏
页码:142.e1 / 142.e9
页数:9
相关论文
共 50 条
  • [1] Cementing an Implant Crown: A Novel Measurement System Using Computational Fluid Dynamics Approach
    Wadhwani, Chandur
    Goodwin, Sabine
    Chung, Kwok-Hung
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 97 - 106
  • [2] THE DISTRIBUTION OF FLUID FORCES ON MODEL ARTERIAL ENDOTHELIUM USING COMPUTATIONAL FLUID-DYNAMICS
    SATCHER, RL
    BUSSOLARI, SR
    GIMBRONE, MA
    DEWEY, CF
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03): : 309 - 316
  • [3] Evaluation of room air distribution systems using computational fluid dynamics
    Gan, GH
    [J]. ENERGY AND BUILDINGS, 1995, 23 (02) : 83 - 93
  • [4] Evaluation of a zonal model for large enclosures using computational fluid dynamics
    Gao, Jun
    Zhao, Jia-ning
    Li, Xiao-dong
    Gao, Fu-sheng
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2007, 6 (02) : 379 - 385
  • [5] Synergistic Enhancement of Protein Recruitment and Retention via Implant Surface Microtopography and Superhydrophilicity in a Computational Fluid Dynamics Model
    Kitajima, Hiroaki
    Hirota, Makoto
    Iwai, Toshinori
    Mitsudo, Kenji
    Saruta, Juri
    Ogawa, Takahiro
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (21)
  • [6] Evaluation of Dynamic Derivatives Using Computational Fluid Dynamics
    Da Ronch, A.
    Vallespin, D.
    Ghoreyshi, M.
    Badcock, K. J.
    [J]. AIAA JOURNAL, 2012, 50 (02) : 470 - 484
  • [7] Evaluation of nacelle drag using Computational Fluid Dynamics
    Trapp, Luis Gustavo
    Argentieri, Henrique Gustavo
    [J]. JOURNAL OF AEROSPACE TECHNOLOGY AND MANAGEMENT, 2010, 2 (02) : 145 - 153
  • [8] Computational Fluid Simulation of Fibrinogen around Dental Implant Surfaces
    Kitajima, Hiroaki
    Hirota, Makoto
    Iwai, Toshinori
    Hamajima, Kosuke
    Ozawa, Ryotaro
    Hayashi, Yuichiro
    Yajima, Yasuharu
    Iida, Masaki
    Koizumi, Toshiyuki
    Kioi, Mitomu
    Mitsudo, Kenji
    Ogawa, Takahiro
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (02)
  • [9] Evaluation of an offshore wind farm computational fluid dynamics model against operational site data
    Richmond, M.
    Antoniadis, A.
    Wang, L.
    Kolios, A.
    Al-Sanad, S.
    Parol, J.
    [J]. OCEAN ENGINEERING, 2019, 193
  • [10] Computational Fluid Dynamics Analysis of Titanium Outflow Pipe Implant for Glaucoma Treatment in Biomechanical Engineering
    Karacali, O.