Biomechanical modelling and computer aided simulation of deep brain retraction in neurosurgery

被引:10
|
作者
Awasthi, Abhilash [1 ]
Gautam, Umesh [1 ]
Bhaskar, Suryanarayanan [2 ]
Roy, Sitikantha [1 ]
机构
[1] Indian Inst Technol Delhi, Dept Appl Mech, New Delhi 110016, India
[2] All India Inst Med Sci Jodhpur, Dept Neurosurg, Jodhpur 342037, Rajasthan, India
关键词
Deep brain retraction; Neurosurgery; Real-time simulation; Surgical training; Finite element brain modelling; ELEMENT; PRESSURE; TISSUE;
D O I
10.1016/j.cmpb.2020.105688
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objectives: Surgical simulators are widely used to promote faster and safer surgical training. They not only provide a platform for enhancing surgical skills but also minimize risks to the patient's safety, operation theatre usage, and financial expenditure. Retracting the soft brain tissue is an unavoidable procedure during any surgery to access the lesioned tissue deep within the brain. Excessive retraction often results in damaging the brain tissue, thus requiring advanced skills and prior training using virtual platforms. Such surgical simulation platforms require an anatomically correct computational model that can accurately predict the brain deformation in real-time. Methods: In this study, we present a 3D finite element brain model reconstructed from MRI dataset. The model incorporates precisely the anatomy and geometrical features of the canine brain. The brain model has been used to formulate and solve a quasi-static boundary value problem for brain deformation during brain retraction. The visco-hyperelastic framework within the theory of non-linear elasticity has been used to set up the boundary value problem. Consequently, the derived non-linear field equations have been solved using finite element solver ABAQUS. Results: The retraction simulations have been performed for two scenarios: retraction pressure in the brain and forces required to perform the surgery. The brain was retracted by 5 mm and retained at that position for 30 minutes, during which the retraction pressure attenuates to 36% of its peak value. Both the model predictions as well as experimental observations on canine brain indicate that brain retraction up to 30 minutes did not cause any significant risk of induced damage. Also, the peak retraction pressure level indicates that intermittent retraction is a safer procedure as compared to the continuous retraction, for the same extent of retraction. Conclusions: The results of the present study indicate the potential of a visco-hyperelastic framework for simulating deep brain retraction effectively. The simulations were able to capture the dominant characteristics of brain tissue undergoing retraction. The developed platform could serve as a basis for the development of a detailed model in the future that can eventually be used for effective preoperative planning and training purposes. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Biomechanical modeling and computer simulation of the brain during neurosurgery
    Miller, Karol
    Joldes, Grand R.
    Bourantas, George
    Warfield, Simon K.
    Hyde, Damon E.
    Kikinis, Ron
    Wittek, Adam
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (10)
  • [2] A COMPUTER-AIDED SIMULATION OF AN ELECTRODE PENETRATION INTO DEEP BRAIN STRUCTURES
    YESHURUN, Y
    ALLON, N
    WOLLBERG, Z
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1981, 14 (01): : 19 - 30
  • [3] COMPUTER AIDED ERGONOMICS THROUGH PARAMETRIC BIOMECHANICAL SIMULATION
    Miehling, Joerg
    Schuhhardt, Juegen
    Paulus-Rohmer, Florian
    Wartzack, Sandro
    [J]. INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 1B, 2016,
  • [4] Modelling brain deformations for computer-integrated neurosurgery
    Miller, K.
    Wittek, A.
    Joldes, G.
    Horton, A.
    Dutta-Roy, T.
    Berger, J.
    Morriss, L.
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2010, 26 (01) : 117 - 138
  • [5] The modelling and simulation method in computer aided cooperation
    Matuszek, Jozef
    Moczala, Aleksander
    [J]. CONTROL AND CYBERNETICS, 2010, 39 (01): : 117 - 131
  • [6] Modelling the biomechanical properties of DNA using computer simulation
    Harris, Sarah Anne
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2006, 364 (1849): : 3319 - 3334
  • [7] CT-AIDED STEREOTAXY FOR FUNCTIONAL NEUROSURGERY AND DEEP BRAIN IMPLANTS
    MUNDINGER, F
    BIRG, W
    [J]. ACTA NEUROCHIRURGICA, 1981, 56 (3-4) : 245 - 246
  • [8] Computer-aided navigation in neurosurgery
    Dieter Hellwig
    [J]. Neurosurgical Review, 2003, 26 (2) : 101 - 101
  • [9] COMPUTER-AIDED STEREOTAXIC NEUROSURGERY
    TANEJA, U
    WALKER, CF
    RICHARDSON, D
    [J]. PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1468 - 1469
  • [10] Computer-aided navigation in neurosurgery
    P. Grunert
    K. Darabi
    J. Espinosa
    R. Filippi
    [J]. Neurosurgical Review, 2003, 26 (2) : 73 - 99