Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?

被引:28
|
作者
Chida, K. [1 ]
Kagaya, Y. [2 ]
Saito, H.
Ishibashi, T.
Takahashi, S. [3 ]
Zuguchi, M.
机构
[1] Tohoku Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol,Aoba Ku, Sendai, Miyagi 980, Japan
[2] Tohoku Univ, Dept Cardiovasc Med, Grad Sch Med, Sendai, Miyagi 980, Japan
[3] Tohoku Univ, Grad Sch Med, Dept Radiol, Sendai, Miyagi 980, Japan
关键词
Angioplasty; catheterization; coronary intervention; interventional; radiation exposure; radiation safety; PERCUTANEOUS CORONARY INTERVENTION; FLUOROSCOPICALLY GUIDED PROCEDURES; REAL-TIME MEASUREMENT; INDUCED SKIN INJURY; RADIOLOGY PROCEDURES; AREA PRODUCT; ANGIOGRAPHY; EXPOSURE; CATHETERIZATION; CARDIOLOGY;
D O I
10.1080/02841850902852752
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac interventional radiology has lower risks than surgical procedures. This is despite the fact that radiation doses from cardiac intervention procedures are the highest of any commonly performed general X-ray examination. Maximum radiation skin doses (MSDs) should be determined to avoid radiation-associated skin injuries in patients undergoing cardiac intervention procedures. However, real-time evaluation of MSD is unavailable for many cardiac intervention procedures. This review describes methods of determining MSD during cardiac intervention procedures. Currently, in most cardiac intervention procedures, real-time measuring of MSD is not feasible. Thus, we recommend that physicians record the patient's total entrance skin dose, such as the dose at the interventional reference point when it can be monitored, in order to estimate MSD in intervention procedures.
引用
收藏
页码:474 / 481
页数:8
相关论文
共 50 条
  • [1] Effective dose to patient during cardiac interventional procedures (Prague workplaces)
    Stisova, V
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) : 271 - 274
  • [2] EVALUATING THE MAXIMUM PATIENT RADIATION DOSE IN CARDIAC INTERVENTIONAL PROCEDURES
    Kato, Mamoru
    Chida, Koichi
    Sato, Tadaya
    Oosaka, Hajime
    Tosa, Tetsuo
    Kadowaki, Ken
    RADIATION PROTECTION DOSIMETRY, 2011, 143 (01) : 69 - 73
  • [3] Patient radiation dosimetry during interventional cardiac procedures
    Omidvar, F.
    Bouzarjomehri, F.
    Falahati, F.
    Zare, M. H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (03): : 511 - 519
  • [4] Patient radiation dose during CT fluoroscopy guided percutaneous interventional procedures
    Daly, BD
    Regits, W
    Pham, CN
    White, DE
    Hartman, EM
    Westerman, BR
    RADIOLOGY, 1999, 213P : 285 - 285
  • [5] Patient radiation dose during diagnostic and interventional cardiology procedures A study in a tertiary hospital
    Anim-Sampong, Samuel
    Antwi, William Kwadwo
    Adomako, John Bright
    Botwe, Benard Ohene
    Sarkodie, Benjamin Dabo
    Brakohiapa, Edmund K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (02) : 298 - 305
  • [6] Radiation exposure during therapeutic cardiac interventional procedures
    Osman, Eltayeb
    Sulieman, A.
    Alzimami, Khalid
    Tamam, N.
    Jambi, Layal K.
    Babikir, E.
    Abd-Elghany, Amr A.
    Abuzaid, M.
    Omer, Hiba
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [7] Patient radiation dose audits for fluoroscopically guided interventional procedures
    Balter, Stephen
    Rosenstein, Marvin
    Miller, Donald L.
    Schueler, Beth
    Spelic, David
    MEDICAL PHYSICS, 2011, 38 (03) : 1611 - 1618
  • [8] Patient radiation exposure measurements during interventional procedures
    Efstathopoulos, EP
    Brountzos, EN
    Alexopoulou, E
    Kelekis, DA
    RADIOLOGY, 2001, 221 : 168 - 168
  • [9] Evaluation of patients' and occupational radiation risk dose during conventional and interventional radiology procedures
    Tamam, Nissren
    Salah, H.
    Almogren, Kholoud S.
    Mahgoub, Omer
    Saeed, Mohammed Khalil
    Abdullah, Yousef
    Tai, Duong Thanh
    Omer, Hiba
    Sulieman, Abdelmoneim
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 207
  • [10] Estimating the maximum radiation skin dose during cardiac interventional procedures using the dose- area product, fluoroscopic time, and patient weight
    Chida, K.
    Saito, H.
    Otani, H.
    Zuguchi, M.
    Shimura, H.
    Nakada, M.
    Takahashi, S.
    Shirato, K.
    EUROPEAN HEART JOURNAL, 2005, 26 : 694 - 694