Microwave plasma source for high current ion beam neutralization

被引:9
|
作者
Korzec, D [1 ]
Müller, A [1 ]
Engemann, J [1 ]
机构
[1] Univ Gesamthsch Wuppertal, Microstruct Res Ctr Fmt, D-42287 Wuppertal, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2000年 / 71卷 / 02期
关键词
D O I
10.1063/1.1150298
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new microwave based plasma source for high current ion beam neutralization is presented. It consists of a tapered WR340 waveguide with a directly coupled 2.45 GHz magnetron and a quartz tube of 40 mm diameter inside the waveguide confined by two graphite electrodes. The upper electrode houses the gas feed, whereas the lower electrode serves as the plasma outlet. Both electrodes can be biased independently. Tuning is done via a magnetically controlled stab inserted into the waveguide. The plasma was characterized by use of the Langmuir probe. The electron concentration of 5x10(11) cm(-3) at 250 W was measured. Typical electron temperature is below 2.5 eV even for pressure as low as 2x10(-3) Pa. The extractable electron current is dependent on microwave power and gas flow. A limitation is caused by the ion saturation current to the negatively biased electrodes. The voltage on the electrodes allows an easy control of electron current. Maximum electron current achieved so far is 400 mA for an argon flow of 5 sccm and microwave power of 300 W. (C) 2000 American Institute of Physics. [S0034-6748(00)65102-X].
引用
收藏
页码:800 / 803
页数:4
相关论文
共 50 条
  • [1] Numerical analysis and optimization of the microwave plasma source for ion beam neutralization
    Medhisuwakul, M.
    Kytzia, S.
    Engemann, J.
    Vilaithong, T.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2006, 15 (03): : 396 - 401
  • [2] A microwave plasma cathode electron gun for ion beam neutralization
    Fusellier, C
    Wartski, L
    Aubert, J
    Schwebel, C
    Coste, P
    Chabrier, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 1153 - 1155
  • [3] Microwave plasma source as an ion beam neutralizer
    Medhisuwakul, M
    Boonyawan, D
    Vilaithong, T
    Engemann, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1684 - 1686
  • [4] ECR plasma source for heavy ion beam charge neutralization
    Efthimion, PC
    Gilson, E
    Grisham, L
    Kolchin, P
    Davidson, RC
    Yu, S
    Logan, BG
    LASER AND PARTICLE BEAMS, 2003, 21 (01) : 37 - 40
  • [5] Long plasma source for heavy ion beam charge neutralization
    Efthimion, Philip C.
    Gilson, Erik P.
    Grisham, Larry
    Davidson, Ronald C.
    Logan, Larry B. Grant
    Seidl, Peter A.
    Waldron, William
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (1-2): : 124 - 127
  • [6] Ferroelectric plasma source for heavy ion beam charge neutralization
    Efthimion, PC
    Gilson, EP
    Grisham, L
    Davidson, RC
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 3028 - 3030
  • [7] RF plasma source for heavy ion beam charge neutralization
    Efthimion, PC
    Gilson, E
    Grisham, L
    Davidson, RC
    Yu, SS
    Logan, BG
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2661 - 2663
  • [8] A microwave plasma cathode for the high-current CHORDIS ion source
    Cojocaru, G
    Wolf, BH
    Emig, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 1344 - 1346
  • [9] CURRENT NEUTRALIZATION OF ION BEAM ROTATING AND PROPAGATING IN PLASMA.
    Aoki, Takayuki
    Niu, Keishiro
    Laser and Particle Beams, 1987, 5 (pt 3) : 481 - 486
  • [10] CURRENT NEUTRALIZATION OF ION-BEAM ROTATING AND PROPAGATING IN PLASMA
    AOKI, T
    NIU, K
    LASER AND PARTICLE BEAMS, 1987, 5 : 481 - 486