Lateral flow biosensor for DNA extraction-free detection of salmonella based on aptamer mediated strand displacement.amplification

被引:142
|
作者
Fang, Zhiyuan [1 ]
Wu, Wei [1 ]
Lu, Xuewen [1 ]
Zeng, Lingwen [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Biomed & Hlth, Key Lab Regenerat Biol, Guangzhou 510530, Guangdong, Peoples R China
来源
关键词
Lateral flow biosensor; Salmonella; Aptamer; Point-of-care; POLYMERASE-CHAIN-REACTION; ESCHERICHIA-COLI O157H7; MULTIPLEX PCR ASSAY; REAL-TIME PCR; QUANTIFICATION; TYPHIMURIUM; BACTERIA; ENTERICA; SEPARATION; OUTBREAK;
D O I
10.1016/j.bios.2014.01.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Convenient and sensitive point-of-care rapid diagnostic tests for food-borne pathogens have been a long-felt need of clinicians. Traditional approaches such as culture-based methods have good sensitivity and specificity, but they tend to be tedious and time-consuming. Herein we present a simple and sensitive aptamer based biosensor for rapid detection of Salmonella enteritidis (S. enteritidis). One of the aptamers specific for the outmembrane of S. enteritidis was used for magnetic bead enrichments. Another aptamer against S. enteritidis was used as a reporter for this pathogen, which was amplified by isothermal strand displacement amplification (SDA) and further detected by a lateral flow biosensor. As low as 10(1) colony forming unit (CFU) of S. enteritidis was detected in this study. Without DNA extraction, the reduced handling and simpler equipment requirement render this assay a simple and rapid alternative to conventional methods. (C) 2014 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
引用
收藏
页码:192 / 197
页数:6
相关论文
共 50 条
  • [1] A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification
    Wu, Wei
    Zhao, Shiming
    Mao, Yiping
    Fang, Zhiyuan
    Lu, Xuewen
    Zeng, Lingwen
    ANALYTICA CHIMICA ACTA, 2015, 861 : 62 - 68
  • [2] Detection of Ochratoxin A in Food by Electrochemical Aptamer Biosensor Based on Strand Displacement Amplification
    Liu W.
    Zhang Y.
    Yang Q.
    Fan S.
    Tian Y.
    Zhang W.
    Journal of Chinese Institute of Food Science and Technology, 2024, 24 (01) : 232 - 241
  • [3] Aptamer-mediated double strand displacement amplification with microchip electrophoresis for ultrasensitive detection of Salmonella typhimurium
    Lu, Yuqi
    Xie, Qihui
    Chen, Jingyi
    Chu, Zhaohui
    Zhang, Fan
    Wang, Qingjiang
    TALANTA, 2024, 273
  • [4] DNA Extraction-Free Loop-Mediated Isothermal Amplification for Rapid and Sensitive Detection of Pratylenchus zeae
    Almeida, Larissa Cavalcante
    Rossato, Mauricio
    Santiago, Thais Ribeiro
    PLANT PATHOLOGY, 2025,
  • [5] Lateral Flow Biosensor for On-Site Multiplex Detection of Viruses Based on One-Step Reverse Transcription and Strand Displacement Amplification
    Lu, Xuewen
    Ding, Kangning
    Fang, Zhiyuan
    Liu, Yilei
    Ji, Tianxing
    Sun, Jian
    Zeng, Zhenling
    He, Limin
    BIOSENSORS-BASEL, 2024, 14 (02):
  • [6] An aptamer biosensor based dual signal amplification system for the detection of salmonella typhimurium
    Li, Ao
    Zuo, Peng
    Ye, Bang-Ce
    ANALYTICAL BIOCHEMISTRY, 2021, 615
  • [7] Signal-off Electrochemiluminescence Biosensor Based on Phi29 DNA Polymerase Mediated Strand Displacement Amplification for MicroRNA Detection
    Chen, Anyi
    Gui, Guo-Feng
    Zhuo, Ying
    Chai, Ya-Qin
    Xiang, Yun
    Yuan, Ruo
    ANALYTICAL CHEMISTRY, 2015, 87 (12) : 6328 - 6334
  • [8] A novel electrochemical biosensor for ultrasensitive and specific detection of DNA based on molecular beacon mediated circular strand displacement and rolling circle amplification
    Cheng, Wei
    Zhang, Wei
    Yan, Yurong
    Shen, Bo
    Zhu, Dan
    Lei, Pinhua
    Ding, Shijia
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 274 - 279
  • [9] Distance-Based Visual miRNA Biosensor with Strand Displacement Amplification-Mediated DNA Hydrogel Assembly
    Yan, Chengyu
    Guo, Jiarong
    Qu, Xiaolin
    Sun, Haixuan
    Chai, Hua
    Miao, Peng
    ACS MATERIALS LETTERS, 2024, 6 (06): : 2111 - 2117
  • [10] A lateral flow biosensor for detection of single nucleotide polymorphism by circular strand displacement reaction
    Xiao, Zhuo
    Lie, Puchang
    Fang, Zhiyuan
    Yu, Luxin
    Chen, Junhua
    Liu, Jie
    Ge, Chenchen
    Zhou, Xuemeng
    Zeng, Lingwen
    CHEMICAL COMMUNICATIONS, 2012, 48 (68) : 8547 - 8549