A non-invasive heart rate and blood pressure monitoring system using piezoelectric and photoplethysmographic sensors

被引:0
|
作者
Samartkit, Piyawat [1 ]
Pullteap, Saroj [1 ]
Bernal, Olivier [2 ]
机构
[1] Silpakorn Univ, Fac Engn & Ind Technol, Dept Mech Engn, Nakhon Pathom 73000, Thailand
[2] Univ Toulouse, LAAS CNRS, CNRS INP, F-31000 Toulouse, France
关键词
Blood pressure monitoring; Modified pulse transit time; Non-invasive health monitoring; Piezoelectric sensor; Photoplethysmographic sensor; CUFF-LESS; ACCURACY;
D O I
10.1016/j.measurement.2022.111211
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, a non-invasive heart rate (HR) and blood pressure (BP) monitoring system using a lead zirconate titanate (PZT) piezoelectric and photoplethysmographic (PPG) sensor has, preliminarily, been investigated. A modified pulse transit time (MPTT) is applied to demodulate HR, systolic blood pressure (SBP), and diastolic blood pressure (DBP) from obtained BP waveforms. In addition, an engineering application software written by LabView programming is, also, developed for dynamic signal monitoring and processing of desired parameters. Consequently, HR and BP measurements on 15 volunteers are performed and validated against a reference digital sphygmomanometer. The results show equivalent HR from both sensors with a mean absolute difference (MAD) of 1.78 beats per minute. Meanwhile, MADs of SBP and DBP measurements are 2.62 and 1.36 mmHg, complying with AAMI-BHS accuracy of "Grade A ", respectively. Therefore, PZT and PPG-based monitoring system could lead to development of accurate, non-invasive, and low-cost HR and BP devices.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Non-invasive cuffless blood pressure and heart rate monitoring using impedance cardiography
    Ghosh, Sudipta
    Chattopadhyay, Bhabani Prasad
    Roy, Ram Mohan
    Mukherjee, Jayanta
    Mahadevappa, Manjunatha
    [J]. INTELLIGENT MEDICINE, 2022, 2 (04): : 199 - 208
  • [2] Non-invasive piezoelectric detection of heartbeat rate and blood pressure
    Al Taradeh, N.
    Bastaki, N.
    Saadat, I.
    Al Ahmad, M.
    [J]. ELECTRONICS LETTERS, 2015, 51 (06) : 452 - 453
  • [3] Heart Rate Monitoring by using Non-invasive Wearable Sensor
    Maria, Aileni Raluca
    Pasca, Sever
    Strungaru, Rodica
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 587 - 590
  • [4] Non-Invasive Heart Rate Monitoring System using Giant Magneto Resistance Sensor
    Kalyan, Kubera
    Chugh, Vinit Kumar
    Anoop, C. S.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4873 - 4876
  • [5] Continuous Non-Invasive Blood Pressure Monitoring Using Photoplethysmography
    Nye, Ross
    Zhang, Zhe
    Fang, Qiang
    [J]. 2015 INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2015, : 176 - 179
  • [6] A non-invasive telemetric heart rate monitoring system based on phonocardiography
    Torres-Pereira, L
    Ruivo, P
    Torres-Pereira, C
    Couto, C
    [J]. ISIE '97 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-3, 1997, : 856 - 859
  • [7] Non-invasive blood pressure monitoring in man
    Portaluppi, F
    [J]. PATHOLOGIE BIOLOGIE, 1996, 44 (03): : 196 - 200
  • [8] Non-invasive monitoring of the human blood pressure
    Holejsovská, P
    Peroutka, Z
    Cengery, J
    [J]. CBMS 2003: 16TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2003, : 301 - 306
  • [9] Advances in Non-Invasive Blood Pressure Monitoring
    Quan, Xina
    Liu, Junjun
    Roxlo, Thomas
    Siddharth, Siddharth
    Leong, Weyland
    Muir, Arthur
    Cheong, So-Min
    Rao, Anoop
    [J]. SENSORS, 2021, 21 (13)
  • [10] Non-invasive sensors for monitoring the body temperature and heart rate of pigs during transport
    Chesmore, ED
    Yoon, CS
    Talling, JC
    Van Driel, KS
    Lake, M
    [J]. PRECISION LIVESTOCK FARMING, 2003, : 33 - 37