Metal on metal -: a new (old) hip bearing system in clinical evaluation.: Prospective 7-year follow-up study

被引:0
|
作者
Jessen, N [1 ]
Nickel, A [1 ]
Schikora, K [1 ]
Büttner-Janz, K [1 ]
机构
[1] Vivantes Klinikum Hellersdorf, Orthopad Klin, D-12621 Berlin, Germany
来源
ORTHOPADE | 2004年 / 33卷 / 05期
关键词
metasul bearing system; Zweymuller; endoprostheses; 7-year follow-up study;
D O I
10.1007/s00132-003-0540-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The problems of wear debris of bearing systems. containing polyethylene used in hip arthroplasty have led to an increased trend to hard on hard bearing surfaces. Based on our own good experiences with the cementless Zweymuller-Alloclassic system,we implanted the same system with metal-on-metal bearing surfaces (Metasul) in 100 cases between October 1993 and November 1994. In order to record potential side effects, specific questioning and a clinical and radiological survey were carried out before surgery and in regular intervals thereafter. Up to date almost all of the patients have had good and excellent results-with an average of more than 90 points in the Harris hip score (47.8 before surgery). There were no cases of revision surgery as a result of aseptic loosening. Two revisions were performed for other reasons (change of the insert, deep infection). No disadvantageous phenomena related to Metasul in the surrounding tissue were found on macroscopic and histologic investigation. The radiological examination did not show any specific signs pertaining to the use of a metal-on-metal bearing system. We also have no grounds to suppose that there are systemic reactions due to chromium or cobalt ions. Up to now, the new metal-on-metal bearing system in connection with a proven hip arthroplasty system has lived up to clinical expectations. With regard to less wear debris, it is justified to implant it in younger patients as well. Other open questions, in particular the possibly improved long-term,results, have,to be answered by continuation of the study.
引用
收藏
页码:594 / 602
页数:9
相关论文
共 50 条
  • [1] An American experience with metal-on-metal total hip arthroplasties - A 7-year follow-up study
    Long, WT
    Dorr, LD
    Gendelman, V
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08): : 29 - 34
  • [2] BIARTICULAR HEMIARTHROPLASTY OF THE HIP - A 7-YEAR FOLLOW-UP
    JAMES, SE
    GALLANNAUGH, SC
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1991, 22 (05): : 391 - 393
  • [3] Clinical outcome of Screw Vent implants -: A 7-year prospective follow-up study
    De Bruyn, H
    Collaert, B
    Lindén, U
    Johansson, C
    Albrektsson, T
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (02) : 139 - 148
  • [4] Metall/Metall—eine neue (alte) Gleitpaarung künstlicher Hüftgelenke in der klinischen BewährungsprobeProspektive Verlaufsbeobachtung über 7 JahreMetal on metal—a new (old) hip bearing system in clinical evaluationProspective 7-year follow-up study
    N. Jessen
    A. Nickel
    K. Schikora
    K. Büttner-Janz
    [J]. Der Orthopäde, 2004, 33 (5): : 602 - 602
  • [5] Metall/Metall—eine neue (alte) Gleitpaarung künstlicher Hüftgelenke in der klinischen BewährungsprobeProspektive Verlaufsbeobachtung über 7 JahreMetal on metal—a new (old) hip bearing system in clinical evaluationProspective 7-year follow-up study
    N. Jessen
    A. Nickel
    K. Schikora
    K. Büttner-Janz
    [J]. Der Orthopäde, 2004, 33 (5): : 594 - 602
  • [6] Hybrid revision total hip arthroplasty - A 7-year follow-up study
    Behairy, Y
    Meldrum, RD
    Harris, WH
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (07): : 829 - 837
  • [7] Screening for developmental dysplasia of the hip:: Results of a 7-year follow-up study
    Sahin, F
    Aktürk, A
    Beyazova, U
    Çakir, B
    Boyunaga, Ö
    Tezcan, S
    Bölükbasi, S
    Kanatli, U
    [J]. PEDIATRICS INTERNATIONAL, 2004, 46 (02) : 162 - 166
  • [8] The Early Results of Metal-on-Metal Hip Resurfacing A Prospective Study at a Minimum Two-Year Follow-Up
    Bergeron, Stephane G.
    Desy, Nicholas M.
    Nikolaou, Vassilios S.
    Debiparshad, Kevin
    Antoniou, John
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2009, 67 (02): : 132 - 134
  • [9] A 7-year follow-up study of threaded implants
    Wu, YM
    Chen, CC
    Wang, JC
    Hon, JM
    Tsai, CC
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 : 710 - 710
  • [10] Clinical Outcome of the Metal-on-Metal Hybrid Corin Cormet 2000 Hip Resurfacing System An up to 11-Year Follow-Up Study
    Gross, Thomas P.
    Liu, Fei
    Webb, Lee A.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (04): : 533 - 538