关键词
Permanent magnet generator; irreversible demagnetization; Online Monitoring;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Irreversible demagnetization of permanent magnet wind turbines is one of the main causes of motor failures. Due to the difficulty in representing irreversible demagnetization faults of wind turbines, online monitoring and fault diagnosis techniques for permanent magnet wind turbines are severely limited. In this paper, Maxwell software is used to build a Permanent magnet generator(PMG) model to simulate the fault characteristics of PMG. 25% and 50% uniform irreversible demagnetization and 50% non-uniform irreversible demagnetization faults of generator are simulated. The characteristics of current harmonics and flux linkage distribution were obtained in this paper, and the correlation between the output current harmonics, motor flux linkage distribution and fault types was established. Compared with the normal motor, the effective value of flux linkage under uniform demagnetization decreases gradually with the increase of the demagnetization degree. When 50% uniform irreversible demagnetization occurs in permanent magnet motor, the effective value of motor flux linkage is only 91.6442Wb, which is only 74.9% of that in the normal motor. The effective value of motor flux linkage gradually decreases with increasing demagnetization under non-uniform demagnetization. The output current produce harmonic current under non-uniform demagnetization, and the contents of 1/2, 2, 5/2, and 7/2 harmonics current changing with the demagnetization area. Our simulation results indicate that the peak value of flux linkage and different frequency harmonics current correspond to different types of irreversible demagnetization faults, which provides a theoretical basis for online monitoring and fault diagnosis of irreversible demagnetization faults in permanent magnet wind generator based on the harmonic of the current and the flux linkage.
引用
收藏
页码:408 / 412
页数:5
相关论文
共 50 条
  • [1] Finite Element Analysis of MW Permanent Magnet Synchronous Generator
    Xu, Chengxin
    [J]. PROCEEDINGS OF THE 2018 3RD INTERNATIONAL WORKSHOP ON MATERIALS ENGINEERING AND COMPUTER SCIENCES (IWMECS 2018), 2018, 78 : 292 - 296
  • [2] Temperature Field of Demagnetization Fault in Permanent Magnet Synchronous Generator
    Zhu, Yingjie
    Li, Xiangfeng
    Zhang, Ming
    Zhang, Zhiyan
    Ren, Zuling
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2022, 40 (01) : 289 - 296
  • [3] Finite Element Demagnetization Analysis of Permanent Magnet Synchronous Motor Considering Magnetization Process
    Sawczuk, Grzegorz
    Junak, Jacek
    [J]. 2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, : 7 - 12
  • [4] Demagnetization Faults Detection in an Axial Flux Permanent Magnet Synchronous Generator
    Barmpatza, Alexandra C.
    Kappatou, Joya C.
    [J]. 2017 IEEE 11TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2017, : 153 - 159
  • [5] Comparison of demagnetization models for finite-element analysis of permanent-magnet synchronous machines
    Ruoho, Sami
    Dlala, Emad
    Arkkio, Antero
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (11) : 3964 - 3968
  • [6] Irreversible Demagnetization Fault Diagnosis of Permanent Magnet Synchronous Motor for Electric Vehicle
    Yoo, Jin-Hyung
    Hwang, Don-Ha
    Jung, Tae-Uk
    [J]. 2015 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2015,
  • [7] On the permanent magnet demagnetization fault in permanent magnet synchronous machines
    Rosero, J. A.
    Cusido, J.
    Garcia, A.
    Ortega, J. A.
    Romeral, L.
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1269 - +
  • [8] Demagnetization effects of surface-mounted permanent magnet synchronous wind generator
    Dalcalı, Adem
    Kurt, Erol
    [J]. Journal of Energy Systems, 2024, 8 (01): : 63 - 74
  • [9] Magnet Demagnetization Observation for Permanent Magnet Synchronous Motor
    Xiao Xi
    Chen Changming
    Zhang Meng
    [J]. ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 3216 - 3219
  • [10] Study on Permanent Magnet Demagnetization Characteristics in Permanent Magnet Synchronous Machines
    Liu, Jizhu
    Yu, Xiaohui
    Wang, Shaohua
    Sun, Mingchong
    [J]. MECHATRONICS AND INTELLIGENT MATERIALS, PTS 1 AND 2, 2011, 211-212 : 127 - +