The accuracy and reliability of measurements made on computer-based digital models

被引:0
|
作者
Quimby, ML
Vig, KWL
Rashid, RG
Firestone, AR
机构
[1] Ohio State Univ, Coll Dent, Sect Orthodont, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Dent, Sect Restorat & Prosthet Dent, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Dent, Sect Orthodont, Columbus, OH 43210 USA
关键词
efficacy; effectiveness; digital models;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
For reasons of convenience and economy, orthodontists who routinely use and maintain pre- and posttreatment plaster casts are beginning to use computer-based digital models. The purpose of this study was to determine the accuracy (validity), reproducibility (reliability), efficacy, and effectiveness of measurements made on computer-based models. A plastic model occlusion ie, dentoform, served as a gold standard to evaluate the systematic errors associated with producing either plaster or computer-based models. Accuracy, reproducibility, efficacy, and effectiveness were tested by comparing the measurements of the computer-based models with the measurements of the plaster models-(1) accuracy: one examiner measuring 10 models made from a dentoform, twice; (2) reproducibility and efficacy: two examiners measuring 50 models made from patients, twice; and (3) effectiveness: 10 examiners measuring 10 models made from patients, twice. Reproducibility (reliability) was tested by using the intraclass correlation coefficient. Repeated measures of analysis of variance for multiple repeated measurements and Student's t-test were used to test for validity. Only measurements of maxillary and mandibular space available made on computer-based models differed from the measurements made on the dentoform gold standard. There was significantly greater variance for measurements made from computer-based models. Reproducibility was high for measurements made on both computer-based and plaster models. In conclusion, measurements made from computer-based models appear to be generally as accurate and reliable as measurements made from plaster models. Efficacy and effectiveness were similar to those of plaster models. Therefore, computer-based models appear to be a clinically acceptable alternative to conventional plaster models.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 50 条
  • [1] ON THE RELIABILITY OF COMPUTER-BASED CLIMATE MODELS
    Scafetta, Nicola
    [J]. ITALIAN JOURNAL OF ENGINEERING GEOLOGY AND ENVIRONMENT, 2019, 19 (01): : 49 - 70
  • [2] COMPUTER-BASED DIGITAL SYSTEM FOR UNDERWATER ACOUSTICAL MEASUREMENTS
    KODOSKY, JL
    NOWLIN, WC
    SHOREY, JL
    TRUCHARD, JJ
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1975, 58 : S19 - S19
  • [3] ACCURACY AND VALIDITY OF COMPUTER-BASED TESTS
    CARR, AC
    ANCILL, RJ
    [J]. BULLETIN OF THE BRITISH PSYCHOLOGICAL SOCIETY, 1983, 36 (MAY): : A49 - A49
  • [4] SAFETY AND RELIABILITY IN COMPUTER-BASED SYSTEMS
    DALE, C
    [J]. DATA PROCESSING, 1984, 26 (10): : 11 - &
  • [5] DESIGNING RELIABILITY INTO COMPUTER-BASED SYSTEMS
    MILLER, W
    [J]. INSTRUMENTS & CONTROL SYSTEMS, 1982, 55 (05): : 45 - 50
  • [6] IMPROVING RELIABILITY IN COMPUTER-BASED SYSTEMS
    DUFFUAA, SO
    RAOUF, A
    [J]. MICROELECTRONICS AND RELIABILITY, 1989, 29 (02): : 177 - 184
  • [7] RELIABILITY OF COMPUTER-BASED SAFETY SYSTEMS
    ONSHUS, T
    BODSBERG, L
    [J]. COMPUTERS AND SAFETY: A FIRST INTERNATIONAL CONFERENCE ON THE USE OF PROGRAMMABLE ELECTRONIC SYSTEMS IN SAFETY RELATED APPLICATIONS, 1989, 314 : 8 - 12
  • [8] MANUAL AND DIGITIZER MEASUREMENTS OF AMYGDALOHIPPOCAMPAL VOLUME - RELIABILITY IN COMPARISON TO COMPUTER-BASED MEASUREMENT
    HOSHIDA, T
    SAKAKI, T
    MORIMOTO, T
    HASHIMOTO, H
    KUROKAWA, SI
    NAKASE, H
    HIRABAYASHI, H
    KAWAGUCHI, S
    TSUNODA, S
    UEMATSU, S
    LESSER, RP
    [J]. PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1995, 49 (03) : S223 - S225
  • [9] Accuracy and Reliability of Space Analysis Measurements in Digital Models with Different Degrees of Crowding
    Lo Giudice, Antonino
    Muraglie, Simone
    Martina, Stefano
    Ronsivalle, Vincenzo
    Leonardi, Rosalia
    [J]. OPEN DENTISTRY JOURNAL, 2019, 13 : 505 - 511
  • [10] Understanding computer-based digital video
    Trey Martindale
    [J]. TechTrends, 2002, 46 (4) : 19 - 22