Correction of slope-intercept glomerular filtration rate measurement without scaling for body size

被引:1
|
作者
McMeekin, Helena [1 ]
Burniston, Maria T. [1 ]
Barnfield, Mark [2 ]
Peters, A. Michael [3 ,4 ]
机构
[1] St Bartholomews, Dept Nucl Med, London, England
[2] St James Univ Hosp, Leeds, W Yorkshire, England
[3] Kings Coll Hosp London, London, England
[4] Mol Imaging Ctr, Harley St, London, England
关键词
Cr-51-EDTA; glomerular filtration rate; Tc-99m-DTPA;
D O I
10.1097/MNM.0000000000001302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim The aim of this study was to evaluate a slope-intercept glomerular filtration rate (GFR) one-compartment correction method based exclusively on the rate constant (alpha(2)) of the exponential between 2 and 4 h post-injection that requires no scaling for BSA. Methods The correction factor is 1/([C.alpha(2)]+1). C depends on the difference between one-compartment-corrected and uncorrected GFR, so varies with different correction procedures. Patients were in four groups: group 1 (Cr-51-EDTA; n = 141) and group 2 (Tc-99m-DTPA; n = 47) had sampling at 2, 3 and 4 h. Groups 3A (Tc-99m-DTPA; n = 168) and 3B (Tc-99m-DTPA; n = 361) gave nine samples up to 480 min. C was calculated from GFR corrected using Brochner-Mortensen (BM) without prior BSA-scaling (C-BM; GFR(BM)), after BSA-scaling then reverse-scaling as per British Nuclear Medicine Society (BNMS) guidelines (C-BNMS; GFR(BNMS)), and after correction using the equations containing 'f' described by Fleming (C-Flem; GFR(Flem)) and Jodal and Brochner-Mortensen (C-JBM; GFR(JBM)). In group 3A, C (C-9) was determined from GFR measured from all nine samples (GFR(9)) and from seven samples (C-7) up to 240 min. In 3B, GFR(C), corrected using 1/([C-9.alpha(2)]+1), was compared with GFR(BM), GFR(BNMS), GFR(Flem) and GFR(JBM) against GFR(9) (gold-standard). Results C derived from these one-compartment correction formulae ranged from 25 to 32 min. In group 3, C-7 and C-9 were 28 +/- 11 and 38 +/- 14 min (P < 0.0001). Biases of GFR(BM), GFR(BNMS), GFR(JBM), GFR(Flem) and GFR(C) against GFR(9) were 2.7, 1.5, 4.2, 3.4 and 0.4 ml/min. Corresponding precisions were 9.3, 7.3, 7.0, 6.7 and 7.6 ml/min. Conclusion Correction using alpha(2) avoids BSA scaling, has a low bias against gold-standard GFR and does not over-correct at high GFR.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 50 条
  • [1] Correction of the slope-intercept method for the measurement of glomerular filtration rate
    Blake, Glen M.
    Barnfield, Mark C.
    Burniston, Maria T.
    Fleming, John S.
    Cosgriff, Philip S.
    Siddique, Musib
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (12) : 1277 - 1283
  • [2] Commentary to 'Correction of the slope-intercept method for the measurement of glomerular filtration rate'
    Jodal, Lars
    Brochner-Mortensen, Jens
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (04) : 407 - 408
  • [3] Robustness of slope-intercept versus slope-only for measurement of glomerular filtration rate
    Peters, AM
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) : 115 - 117
  • [4] Errors in measurement of glomerular filtration rate using the slope-intercept technique and their identification
    Oliveira, Ana
    Conway, Lauren
    Heraghty, Neil
    Peters, A. Michael
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2024, 45 (01) : 51 - 60
  • [5] Calculating the precision of slope-intercept glomerular filtration rate measurements
    Memmott, Matthew J.
    Lawson, Richard S.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2022, 43 (08) : 959 - 966
  • [6] Robustness of slope-intercept versus slope-only for measurement of glomerular filtration rate - Reply
    De Sadeleer, C
    Piepsz, A
    Ham, HR
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) : 117 - 117
  • [7] Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (12) : 1086 - 1092
  • [8] The effect of measurement errors on glomerular filtration rate: a comparison of the slope-intercept and slope-only methods
    Holness, J. L.
    Warwick, J. M.
    Fleming, J. S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S358 - S358
  • [9] Glomerular filtration rate estimation by use of a correction formula for slope-intercept plasma iohexol clearance in cats
    Finch, Natalie C.
    Syme, Harriet M.
    Elliott, Jonathan
    Peters, Adrien M.
    Gerritsen, Robert
    Croubels, Siska
    Heiene, Reidun
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (12) : 1652 - 1659
  • [10] The effect of measurement errors on glomerular filtration rate: a comparison of the slope-intercept, single-sample and slope-only methods
    Holness, J.
    Fleming, J.
    Warwick, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S19 - S19