A quantitative evaluation study of four-dimensional gated cardiac SPECT reconstruction

被引:22
|
作者
Jin, Mingwu [2 ,3 ]
Yang, Yongyi [1 ]
Niu, Xiaofeng [1 ]
Marin, Thibault [1 ]
Brankov, Jovan G. [1 ]
Feng, Bing [4 ]
Pretorius, P. Hendrik [4 ]
King, Michael A. [4 ]
Wernick, Miles N. [1 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] Univ Colorado Denver, Sch Med, C TRIC, Aurora, CO 80045 USA
[3] Univ Colorado Denver, Sch Med, Dept Radiol, Aurora, CO 80045 USA
[4] Univ Massachusetts, Sch Med, Dept Radiol, Div Nucl Med, Worcester, MA 01655 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 18期
基金
美国国家卫生研究院;
关键词
SCATTER CORRECTION; IMAGE-RECONSTRUCTION; MOTION ESTIMATION; EMISSION;
D O I
10.1088/0031-9155/54/18/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In practice, gated cardiac SPECT images suffer from a number of degrading factors, including distance-dependent blur, attenuation, scatter and increased noise due to gating. Recently, we proposed a motion-compensated approach for four-dimensional (4D) reconstruction for gated cardiac SPECT and demonstrated that use of motion-compensated temporal smoothing could be effective for suppressing the increased noise due to lowered counts in individual gates. In this work, we further develop this motion-compensated 4D approach by also taking into account attenuation and scatter in the reconstruction process, which are two major degrading factors in SPECT data. In our experiments, we conducted a thorough quantitative evaluation of the proposed 4D method using Monte Carlo simulated SPECT imaging based on the 4D NURBS-based cardiac-torso (NCAT) phantom. In particular, we evaluated the accuracy of the reconstructed left ventricular myocardium using a number of quantitative measures including regional bias-variance analyses and wall intensity uniformity. The quantitative results demonstrate that use of motion-compensated 4D reconstruction can improve the accuracy of the reconstructed myocardium, which in turn can improve the detectability of perfusion defects. Moreover, our results reveal that while traditional spatial smoothing could be beneficial, its merit would become diminished with the use of motion-compensated temporal regularization. As a preliminary demonstration, we also tested our 4D approach on patient data. The reconstructed images from both simulated and patient data demonstrated that our 4D method can improve the definition of the LV wall.
引用
收藏
页码:5643 / 5659
页数:17
相关论文
共 50 条
  • [1] Four-dimensional gated cardiac SPECT reconstruction and evaluation study
    Jin, Mingwu
    Yang, Yongyi
    Brankov, Jovan G.
    Wernick, Miles N.
    Feng, Bing
    Pretorius, P. Hendrik
    King, Michael A.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3894 - +
  • [2] Four-dimensional reconstruction of gated cardiac SPECT with attenuation and scatter compensation
    Jin, Mingwu
    Yang, Yongyi
    Brankov, Jovan G.
    Wernick, Miles N.
    Feng, Bing
    King, Micheal A.
    [J]. 2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 169 - +
  • [3] A priori motion models for four-dimensional reconstruction in gated cardiac SPECT
    Lalush, DS
    Cui, L
    Tsui, BMW
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1923 - 1927
  • [4] Four-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging
    Rahmim, Arman
    Tang, Jing
    Zaidi, Habib
    [J]. PET CLINICS, 2013, 8 (01) : 51 - +
  • [5] A quantitative study of motion estimation methods on 4D cardiac gated SPECT reconstruction
    Qi, Wenyuan
    Yang, Yongyi
    Niu, Xiaofeng
    King, Michael A.
    [J]. MEDICAL PHYSICS, 2012, 39 (08) : 5182 - 5193
  • [6] Reconstruction of dynamic gated cardiac SPECT
    Jin, Mingwu
    Yang, Yongyi
    King, Michael A.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4384 - 4394
  • [7] Four-Dimensional Imaging of Cardiac Trabeculae Contracting In Vitro Using Gated OCT
    Cheuk, Ming L.
    Anderson, Alexander J.
    Han, June-Chiew
    Lippok, Norman
    Vanholsbeeck, Frederique
    Ruddy, Bryan P.
    Loiselle, Denis S.
    Nielsen, Poul M. F.
    Taberner, Andrew J.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (01) : 218 - 224
  • [8] Evaluation of Four-Dimensional Dose Reconstruction Under Breathing Irregularity
    Yoon, J.
    Yeo, I.
    Jung, J.
    Yi, B.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3342 - 3342
  • [9] Four-dimensional registration of respiratory gated PET
    Thorndyke, B.
    Schreibmann, E.
    Hsu, A.
    Fox, T.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S656 - S657
  • [10] Four-dimensional helicity scheme and dimensional reconstruction
    Boughezal, Radja
    Melnikov, Kirill
    Petriello, Frank
    [J]. PHYSICAL REVIEW D, 2011, 84 (03):