Analysis and suppression of interference for on-line monitoring of partial discharge of power transformers

被引:0
|
作者
Wang, C
Jin, XH
Cheng, TC
Zhang, SB
Dong, XZ
Wang, ZD
Lin, D
Zhu, DH
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The key to on-line partial discharge (PD) monitoring of power transformers is how to suppress interference effectively. This paper reports an interference qualitative and quantitative analysis on site using a Fast Fourier Transform (FFT) technique. Various periodic interferences have been found, which emanated from the carrier communication, thyristor switching, and high frequency protection signals of power system as well as radio broadcasting signals. LMS adaptive digital filter and FFT threshold digital filter can be used to eliminate continuous periodic noises for on-line PD monitoring. However, they suffer from their own intrinsic weaknesses. Therefore, a multi-band-pass digital filter based on FFT has been developed. It is an much better method for the purpose of suppressing continuous periodic interferences.
引用
收藏
页码:530 / 533
页数:4
相关论文
共 50 条
  • [1] On-line Partial Discharge Monitoring of Substation Power Transformers
    Huzmezan, Mihai
    [J]. 2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 347 - 352
  • [2] On-line partial discharge calibration and monitoring for power transformers
    Farag, AS
    Shewhdi, MH
    Jin, X
    Wang, C
    Cheng, TC
    Dong, X
    Gao, S
    Jing, W
    Wang, Z
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1999, 50 (01) : 47 - 54
  • [3] Interference rejection for on-line PD monitoring of power transformers
    Wang, CC
    Jin, XH
    Jing, WH
    Cheng, TC
    Zhang, SB
    Dong, XZ
    Wang, ZD
    Lin, D
    Zhu, DH
    [J]. CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 24 - 27
  • [4] Study of on-line monitoring method of partial discharge for power transformers based on RFCT and microstrip antenna
    Cheng, YH
    Chen, Y
    Liu, T
    Xu, XW
    Ji, LL
    Chen, W
    Chen, LX
    [J]. PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING CONFERENCE, 2005, : 103 - 107
  • [5] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    [J]. IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [6] On-line partial discharge measurement on instrument transformers
    Blackburn, TR
    Phung, BT
    Liu, Z
    James, RE
    [J]. 1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 497 - 500
  • [7] A novel method for continuous periodic interference suppression in on-line PD monitoring of transformers
    Yang, Yongming
    Yu, Xinghuo
    Sun, Caixin
    Wang, Quandi
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 464 - +
  • [8] A New Method for On-Line Monitoring of Bushings and Partial Discharges of Power Transformers
    Koch, Maik
    Krueger, Michael
    [J]. PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1205 - 1208
  • [9] On-line condition monitoring of power transformers
    Tenbohlen, S
    Figel, F
    [J]. 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2211 - 2216
  • [10] On-Line Partial Discharge Monitoring and Diagnostic System for Power Transformer
    林渡
    姜磊
    李福祺
    朱德恒
    谈克雄
    吴成琦
    金显贺
    王昌长
    郑振中
    [J]. Tsinghua Science and Technology, 2005, (05) : 598 - 604