Second-order calibration of excitation-emission matrix fluorescence spectra for determination of glutathione in human plasma

被引:7
|
作者
Hemmateenejad, Bahram [1 ]
Rezaei, Zahra [2 ]
Zaeri, Sasan [2 ]
机构
[1] Shiraz Univ, Dept Chem, Shiraz 71454, Iran
[2] Shiraz Univ Med Sci, Dept Med Chem, Fac Pharm, Shiraz, Iran
基金
美国国家科学基金会;
关键词
Glutathione; Fluorescence; Excitation-emission; Second-order calibration; Standard addition; Plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; PROTEIN MIXED DISULFIDES; MULTIVARIATE CALIBRATION; PRECOLUMN DERIVATIZATION; REDUCED GLUTATHIONE; FLUOROMETRIC ASSAY; O-PHTHALALDEHYDE; BLOOD; APOPTOSIS; THIOLS;
D O I
10.1016/j.talanta.2009.04.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid non-separative spectroflourimetric method based on the second-order calibration of the excitation-emission data matrix was proposed for the determination of glutathione (GSH) in human plasma. In the phosphate buffer solution of pH 8.0 GSH reacts with ortho-phthaldehyde (OPA) to yield a fluorescent adduct with maximum fluorescence intensity at about 420 nm. To handle the interfering effects of the OPA adducts with aminothiols other than GSH in plasma as well as intrinsic fluorescence of human plasma, parallel factor (PARAFAC) analysis as an efficient three-way calibration method was employed. In addition, to model the indirect interfering effect of the plasma matrix, PARAFAC was coupled with standard addition method. The two-component PARAFAC modeling of the excitation-emission matrix fluorescence spectra accurately resolved the excitation and emission spectra of GSH, plasma (or plasma constituents). The concentration-related PARAFAC score of GSH represented a linear correlation with the concentration of added GSH, similar to that is obtained in simple standard addition method. Using this standard addition curve, the GSH level in plasma was found to be 6.10 +/- 1.37 mu mol L-1. The accuracy of the method was investigated by analysis of the plasma samples spiked with 1.0 mu mol L-1 of GSH and a recovery of 97.5% was obtained. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:648 / 656
页数:9
相关论文
共 50 条
  • [1] Determination of Psoralen in Human Plasma Using Excitation-Emission Matrix Fluorescence Coupled to Second-order Calibration
    A-Lin Xia
    Hai-Long Wu
    Shao-Hua Zhu
    Qing-Juan Han
    Yan Zhang
    Ru-Qin Yu
    [J]. Analytical Sciences, 2008, 24 : 1171 - 1176
  • [2] Determination of psoralen in human plasma using excitation-emission matrix fluorescence coupled to second-order calibration
    Xia, A-Lin
    Wu, Hai-Long
    Zhu, Shao-Hua
    Han, Qing-Juan
    Zhang, Yan
    Yu, Ru-Qin
    [J]. ANALYTICAL SCIENCES, 2008, 24 (09) : 1171 - 1176
  • [3] Determination of Sulpiride in Human Urine Using Excitation-Emission Matrix Fluorescence Coupled with Second-order Calibration
    Jin-Fang Nie
    Hai-Long Wu
    A-Lin Xia
    Shao-Hua Zhu
    Ying-Chao Bian
    Shu-Fang Li
    Ru-Qin Yu
    [J]. Analytical Sciences, 2007, 23 : 1377 - 1382
  • [4] Second-order calibration of excitation-emission matrix fluorescence spectra for the determination of N-phenylanthranilic acid derivatives
    de la Peña, AM
    Mansilla, AE
    Díez, NM
    Gil, DB
    Olivieri, AC
    Escandar, GM
    [J]. APPLIED SPECTROSCOPY, 2006, 60 (03) : 330 - 338
  • [5] Determination of sulpiride in human urine using excitation-emission matrix fluorescence coupled with second-order calibration
    Nie, Jin-Fang
    Wu, Hai-Long
    Xia, A-Lin
    Zhu, Shao-Hua
    Bian, Ying-Chao
    Li, Shu-Fang
    Yu, Ru-Qin
    [J]. ANALYTICAL SCIENCES, 2007, 23 (12) : 1377 - 1382
  • [6] Simultaneous determination of metoprolol and α-hydroxymetoprolol in human plasma using excitation-emission matrix fluorescence coupled with second-order calibration methods
    Gu, Hui-Wen
    Wu, Hai-Long
    Liu, Ya-Juan
    Yin, Xiao-Li
    Su, Zhi-Yi
    Li, Shan-Shan
    Yu, Ru-Qin
    [J]. BIOANALYSIS, 2012, 4 (23) : 2781 - 2793
  • [7] Determination of Carbendazim in Bananas by Excitation-Emission Matrix Fluorescence with Three Second-order Calibration Methods
    Shao-Hua Zhu
    Hai-Long Wu
    A-Lin Xia
    Qing-Juan Han
    Yan Zhang
    [J]. Analytical Sciences, 2007, 23 : 1173 - 1177
  • [8] Determination of Illegal Drugs in Urine Using Excitation-emission Matrix Fluorescence Coupled with Second-order Calibration
    Xu Buyi
    Ye Yi
    Ruan Ruoyun
    Yan Youyi
    Liao Linchuan
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2015, 36 (09): : 1667 - 1673
  • [9] A Comparison of Second-Order Calibration Methods Applied to Excitation-Emission Matrix Fluorescence Data
    Chen, Hui
    Lin, Zan
    Wu, Tong
    Tan, Chao
    [J]. JOURNAL OF CHEMISTRY, 2014, 2014
  • [10] Determination of pesticides in honey using excitation-emission matrix fluorescence coupled with second-order calibration and second-order standard addition methods
    Zhu, Shao-Hua
    Wu, Hai-Long
    Li, Bang-Rui
    Xia, A. -Lin
    Han, Qing-Juan
    Zhang, Yan
    Bian, Ying-Chao
    Yu, Ru-Qin
    [J]. ANALYTICA CHIMICA ACTA, 2008, 619 (02) : 165 - 172