Experimental investigation on the internal working process of a CO2 rotary vane expander

被引:68
|
作者
Yang, B. [1 ]
Peng, X. [1 ,2 ]
He, Z. [1 ]
Guo, B. [1 ]
Xing, Z. [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Rotary vane expander; Transcritical CO2 cycle; Working process; Leakage; PISTON EXPANDER; CYCLES;
D O I
10.1016/j.applthermaleng.2008.11.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the experimental investigation on the internal working process especially the internal leakage of a rotary vane expander prototype, which was developed to replace the throttling valve to improve the Coefficient of Performance (COP) of the transcritical CO2 refrigeration cycle. The pressure diagram as a function of the rotation angle (p-0 diagram) was recorded by two pressure sensors arranged within the expansion chamber, based on which the features of the working process were analyzed and effects of the some improvement measures on the internal leakage were discussed. Compared with the ideal p-0 diagram, the recorded diagrams presented more rapid decrease in the pressure during expansion process, which was attributed to serious leakage within the expander. Further analysis of the recorded p-0 diagrams showed that three adjacent vanes instead of two formed an integrated working chamber, which implied that the in-between vane did not contact the cylinder wall at all, and this guess was proved by the high speed video recording of the running rotor together with the vanes during operation of the expander in CO2 system. By arranging springs in the vane slots, tight contact between the vanes and the cylinder wall was ensured and hereby the working process was improved. The gap between the suction and discharge ports was another important leakage path and installation of a seal there could increase the pressure difference through the expander by 1.5-2.5 MPa by decreasing the leakage directly from the high-pressure suction chamber to the low-pressure discharge chamber. Performance test of the modified expander prototype with springs in the slots and seal at the seal arc showed that the volumetric efficiency increased from 17% to 30% and the isentropic efficiency from 9% to 23% at the speed of 800 rpm. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2289 / 2296
页数:8
相关论文
共 50 条
  • [1] Study of a Rotary Vane Expander for the Transcritical CO2 Cycle-Part I: Experimental Investigation
    Yang, Bingchun
    Peng, Xueyuan
    Sun, Shaoyi
    Guo, Bei
    Xing, Ziwen
    [J]. HVAC&R RESEARCH, 2009, 15 (04): : 673 - 688
  • [2] A study of the vane dynamics in a rotary vane expander for the transcritical CO2 refrigeration cycle
    Yang, B.
    Peng, X.
    Sun, S.
    Guo, B.
    Xing, Z.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A4) : 429 - 440
  • [3] Experimental investigation of internal leakages and effects of lubricating oil on the performance of a four-intersecting-vane rotary expander
    Murthy, Anarghya Ananda
    Norris, Stuart
    Subiantoro, Alison
    [J]. ENERGY, 2022, 238
  • [4] NUMERICAL STUDY ON THE PERFORMANCE IMPROVEMENT OF A ROTARY VANE EXPANDER FOR A CO2 HEAT PUMP CYCLE
    Kim, Hyun Jin
    Kim, Woo Young
    Ahn, Jong Min
    Cho, Sung Oug
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (04) : 311 - 319
  • [5] Theoretical, CFD modelling and experimental investigation of a four-intersecting-vane rotary expander
    Murthy, Anarghya Ananda
    Krishan, Gopal
    Shenoy, Praveen
    Patil, Ishwaragouda S.
    [J]. APPLIED ENERGY, 2024, 353
  • [6] Study of a Rotary Vane Expander for the Transcritical CO2 Cycle-Part II: Theoretical Modeling
    Jia, Xiaohan
    Zhang, Bo
    Yang, Bingchun
    Peng, Xueyuan
    [J]. HVAC&R RESEARCH, 2009, 15 (04): : 689 - 709
  • [7] Performance of Vane-Type CO2 Expander and Characteristics of Transcritical Expansion Process
    Fukuta, Mitsuhiro
    Yanagisawa, Tadashi
    Higashiyama, Masashi
    Ogi, Yasuhiro
    [J]. HVAC&R RESEARCH, 2009, 15 (04): : 711 - 727
  • [8] Improved rotary vane expander for trans-critical CO2 cycle by introducing high-pressure gas into the vane slots
    Jia, Xiaohan
    Zhang, Bo
    Pu, Lei
    Guo, Bei
    Peng, Xueyuan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (03): : 732 - 741
  • [9] Performance investigation of a novel expander coupling organic Rankine cycle: Variable expansion ratio rotary vane expander for variable working conditions
    Yan, Jiayao
    Han, Yongqiang
    Tian, Jing
    Xu, Yun
    Zhang, Yiming
    Chen, Ruolong
    [J]. APPLIED THERMAL ENGINEERING, 2019, 152 : 573 - 581
  • [10] Dual intake rotary vane expander technology: Experimental and theoretical assessment
    Fatigati, Fabio
    Di Bartolomeo, Marco
    Cipollone, Roberto
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 186 : 156 - 167