Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery

被引:42
|
作者
Werner, Theresa [1 ,2 ,3 ]
Berthold, Jonathan [1 ,2 ,3 ]
Hueso-Gonzalez, Fernando [4 ,5 ]
Koegler, Toni [1 ,2 ,3 ]
Petzoldt, Johannes [6 ]
Roemer, Katja [7 ]
Richter, Christian [1 ,2 ,3 ]
Rinscheid, Andreas [8 ]
Straessner, Arno [9 ]
Enghardt, Wolfgang [1 ,2 ,3 ,10 ,11 ]
Pausch, Guntram [1 ,2 ,3 ]
机构
[1] Tech Univ Dresden, OncoRay Natl Ctr Radiat Res Oncol, Fac Med, Dresden, Germany
[2] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol OncoRay, Dresden, Germany
[4] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[5] Harvard Med Sch, Boston, MA 02115 USA
[6] Ion Beam Applicat SA, Louvain La Neuve, Belgium
[7] Helmholtz Zentrum Dresden Rossendorf, Inst Radiat Phys, Dresden, Germany
[8] Ulm Univ, Dept Nucl Med, Med Radiat Phys, Ulm, Germany
[9] Tech Univ Dresden, Inst Nucl & Particle Phys, Dresden, Germany
[10] German Canc Consortium DKTK, Dresden, Germany
[11] German Canc Res Ctr, Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 10期
基金
欧盟地平线“2020”;
关键词
proton therapy; range verification; prompt gamma-ray timing; PENCIL BEAMS; SLIT-CAMERA; VERIFICATION; OPTIMIZATION;
D O I
10.1088/1361-6560/ab176d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In proton therapy, patients benefit from the precise deposition of the dose in the tumor volume due to the interaction of charged particles with matter. Currently, the determination of the beam range in the patient's body during the treatment is not a clinical standard. This lack causes broad safety margins around the tumor, which limits the potential of proton therapy. To overcome this obstacle, different methods are under investigation aiming at the verification of the proton range in real time during the irradiation. One approach is the prompt gamma-ray timing (PGT) method, where the range of the primary protons is derived from time-resolved profiles (PGT spectra) of promptly emitted gamma rays, which are produced along the particle track in tissue. After verifying this novel technique in an experimental environment but far away from treatment conditions, the translation of PGT into clinical practice is intended. Therefore, new hardware was extensively tested and characterized using short irradiation times of 70 ms and clinical beam currents of 2 nA. Experiments were carried out in the treatment room of the University Proton Therapy Dresden. A pencil beam scanning plan was delivered to a target without and with cylindrical air cavities of down to 5 mm thickness. The range shifts of the proton beam induced due to the material variation could be identified from the corresponding PGT spectra, comprising events collected during the delivery of a whole energy layer. Additionally, an assignment of the PGT data to the individual pencil beam spots allowed a spot-wise analysis of the variation of the PGT distribution mean and width, corresponding to range shifts produced by the different air cavities. Furthermore, the paper presents a comprehensive software framework which standardizes future PGT analysis methods and correction algorithms for technical limitations that have been encountered in the presented experiments.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Prompt Gamma-ray Timing experiment during different modalities of proton beam delivery
    Kormoll, T.
    Duplicy, A.
    Enghardt, W.
    Golnik, C.
    Loeschner, R.
    Petzoldt, J.
    Werner, T.
    Pausch, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S60 - S60
  • [2] Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector
    Verburg, J.
    Testa, M.
    Cascio, E.
    Bortfeld, T.
    Lu, H.
    Seco, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 495 - 495
  • [3] Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams
    Verburg, J.
    Bortfeld, T.
    Seco, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3548 - 3548
  • [4] Range Verification in Proton Therapy by Prompt Gamma-Ray Timing (PGT): Steps towards Clinical Implementation
    Werner, Theresa
    Berthold, Jonathan
    Enghardt, Wolfgang
    Hueso-Gonzalez, Fernando
    Koegler, Toni
    Petzoldt, Johannes
    Richter, Christian
    Rinscheid, Andreas
    Roemer, Katja
    Ruhnau, Kai
    Smeets, Julien
    Stein, Juergen
    Straessner, Arno
    Wolf, Andreas
    Pausch, Guntram
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [5] Clinical Translation of Prompt Gamma-Ray Spectroscopy for In Vivo Proton Range Verification
    Verburg, J.
    Ruggieri, T.
    Botas, P.
    Cascio, E.
    Hueso-Gonzalez, F.
    Rabe, M.
    BortfeId, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [6] Proton range verification through prompt gamma-ray spectroscopy
    Verburg, Joost M.
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7089 - 7106
  • [7] A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification
    Verburg, J.
    Bortfeld, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757
  • [8] Development of a Clinical Prototype for Range Verification in Proton Therapy based on Prompt Gamma-Ray Spectroscopy
    Hueso-Gonzalez, F.
    Rabe, M.
    Ruggieri, T. A.
    Bortfeld, T.
    Verburg, J. M.
    [J]. 2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] Particle range retrieval in heterogeneous phantoms with the prompt gamma ray timing method at a clinical proton accelerator
    Hueso-Gonzalez, F.
    Golnik, C.
    Berthel, M.
    Dreyer, A.
    Enghardt, W.
    Fiedler, F.
    Heidel, K.
    Janssens, G.
    Kormoll, T.
    Petzoldt, J.
    Prieels, D.
    Priegnitz, M.
    Roemer, K. E.
    Smeets, J.
    Sobiella, M.
    Vander Stappen, F.
    Wagner, A.
    Weinberger, D.
    Pausch, G.
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [10] A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy
    Hueso-Gonzalez, Fernando
    Rabe, Moritz
    Ruggieri, Thomas A.
    Bortfeld, Thomas
    Verburg, Joost M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18):