Biomechanical analysis of the upper thoracic spine after decompressive procedures

被引:18
|
作者
Healy, Andrew T. [1 ]
Lubelski, Daniel [2 ]
Mageswaran, Prasath [3 ]
Bhowmick, Deb A. [4 ]
Bartsch, Adam J. [3 ]
Benzel, Edward C. [1 ]
Mroz, Thomas E. [1 ]
机构
[1] Cleveland Clin, Neurol Inst, Dept Neurosurg, Cleveland, OH 44118 USA
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH 44195 USA
[3] Cleveland Clin, Head Neck & Spine Res Lab, Lutheran Hosp, Cleveland, OH 44195 USA
[4] Univ N Carolina, Dept Neurosurg, Chapel Hill, NC 27599 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 06期
关键词
Thoracic; Spine; Decompression; Costotransversectomy; Biomechanics; Cadaver; RIB CAGE; MOTION; STABILITY; STIFFNESS; STERNUM; MODEL;
D O I
10.1016/j.spinee.2013.11.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Decompressive procedures such as laminectomy, facetectomy, and costotransversectomy are routinely performed for various pathologies in the thoracic spine. The thoracic spine is unique, in part, because of the sternocostovertebral articulations that provide additional strength to the region relative to the cervical and lumbar spines. During decompressive surgeries, stability is compromised at a presently unknown point. PURPOSE: To evaluate thoracic spinal stability after common surgical decompressive procedures in thoracic spines with intact sternocostovertebral articulations. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Fresh-frozen human cadaveric spine specimens with intact rib cages, C7-L1 (n=9), were used. An industrial robot tested all spines in axial rotation (AR), lateral bending (LB), and flexion-extension (FE) by applying pure moments (+/- 5 Nm). The specimens were first tested in their intact state and then tested after each of the following sequential surgical decompressive procedures at T4-T5 consisting of laminectomy; unilateral facetectomy; unilateral costotransversectomy, and subsequently instrumented fusion from T3-T7. RESULTS: We found that in all three planes of motion, the sequential decompressive procedures caused no statistically significant change in motion between T3-T7 or T1-T12 when compared with intact. In comparing between intact and instrumented specimens, our study found that instrumentation reduced global range of motion (ROM) between T1-T12 by 16.3% (p=.001), 12% (p=.002), and 18.4% (p=.0004) for AR, FE, and LB, respectively. Age showed a negative correlation with motion in FE (r= 0.78, p=.01) and AR (r= 0.7, p=.04). CONCLUSIONS: Thoracic spine stability was not significantly affected by sequential decompressive procedures in thoracic segments at the level of the true ribs in all three planes of motion in intact thoracic specimens. Age appeared to negatively correlate with ROM of the specimen. Our study suggests that thoracic spinal stability is maintained immediately after unilateral decompression at the level of the true ribs. These preliminary observations, however, do not depict the long-term sequelae of such procedures and warrant further investigation. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1010 / 1016
页数:7
相关论文
共 50 条
  • [1] FUNCTIONAL RECOVERY AFTER DECOMPRESSIVE OPERATION FOR THORACIC AND LUMBAR SPINE FRACTURES
    BENZEL, EC
    LARSON, SJ
    NEUROSURGERY, 1986, 19 (05) : 772 - 778
  • [2] BIOMECHANICAL ANALYSIS OF POSTERIOR INSTRUMENTATION SYSTEMS AFTER DECOMPRESSIVE LAMINECTOMY - AN UNSTABLE CALF-SPINE MODEL
    GURR, KR
    MCAFEE, PC
    SHIH, CM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05): : 680 - 691
  • [3] Biomechanical Analysis of Derotation of the Thoracic Spine Using Pedicle Screws
    Cheng, Ivan
    Hay, David
    Iezza, Alex
    Lindsey, Derek
    Lenke, Lawrence G.
    SPINE, 2010, 35 (10) : 1039 - 1043
  • [4] A biomechanical assessment of thoracic spine stapling
    Puttlitz, Christian M.
    Masaru, Fujita
    Barkley, Antonia
    Diab, Mohammed
    Acaroglu, Emre
    SPINE, 2007, 32 (07) : 766 - 771
  • [5] Clinical outcomes after decompressive laminectomy for symptomatic ossification of ligamentum flavum at the thoracic spine
    Zhong, Zhao-Ming
    Wu, Qian
    Meng, Ting-Ting
    Zhu, Yong-Jian
    Qu, Dong-Bin
    Wang, Ji-Xing
    Jiang, Jian-Ming
    Lu, Kai-Wu
    Zheng, Shuai
    Zhu, Si-Yuan
    Chen, Jian-Ting
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 28 : 77 - 81
  • [6] Pedicle and transverse process screws of the upper thoracic spine - Biomechanical comparison of loads to failure
    Heller, JG
    Shuster, JK
    Hutton, WC
    SPINE, 1999, 24 (07) : 654 - 658
  • [7] ROENTGENOGRAPHIC ANALYSIS OF ACUTE FRACTURES OF THE UPPER THORACIC SPINE
    THAYER, C
    SHAPIRO, H
    ROGERS, LF
    WEINBERG, P
    KIM, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 133 (02) : 345 - 345
  • [8] Posterior Extensive Circumferential Decompressive Reconstructive Technique in Surgical Treatment of Upper Thoracic Spine Compressive Lesions
    Omran, Khaled
    Abdel-Fattah, Ahmed S.
    WORLD NEUROSURGERY, 2019, 123 : E501 - E508
  • [9] Biomechanical Comparison of Costotransverse Process Screw Fixation and Pedicle Screw Fixation of the Upper Thoracic Spine
    Little, Andrew S.
    Brasiliense, Leonardo B. C.
    Lazaro, Bruno C. R.
    Reyes, Phillip M.
    Dickman, Curtis A.
    Crawford, Neil R.
    NEUROSURGERY, 2010, 66 (03) : 178 - 182
  • [10] BIOMECHANICAL EFFECTS OF LAMINECTOMY ON THORACIC SPINE STABILITY
    YOGANANDAN, N
    MAIMAN, DJ
    PINTAR, FA
    BENNETT, GJ
    LARSON, SJ
    SONNTAG, VKH
    DUNSKER, SB
    NEUROSURGERY, 1993, 32 (04) : 604 - 610