Leakage of polymethylmethacrylate in percutaneous vertebroplasty: Comparison of osteoporotic vertebral compression fractures with and without an intravertebral vacuum cleft

被引:36
|
作者
Jung, Jee Young
Lee, Min Hee
Ahn, Joong Mo
机构
[1] Sungkyunkwan Univ Sch Med, Kangbuk Samsung Hosp, Dept Radiol, Seoul 110746, South Korea
[2] Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[3] Samsung Med Ctr, Ctr Imaging Sci, Seoul, South Korea
[4] Univ Iowa Hosp & Clin, Dept Radiol, Iowa City, IA 52242 USA
关键词
vertebroplasty; complications; compression fracture; computed tomography;
D O I
10.1097/00004728-200605000-00025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We compared polymethylmethacrylate (PMMA) leakage from vertebral bodies in osteoporotic compression fractures with and without intravertebral vacuum clefts (IVCs) on computed tomography (CT) after vertebroplasty. Methods: Percutaneous vertebroplasty was performed in 59 patients, comprising 36 compression fractures with IVCs in 33 patients and 49 fractures without IVCs in 26 patients. All patients underwent post-procedural CT of treated and adjacent vertebral bodies. CT findings and clinical complications were assessed retrospectively with regard to the presence of PMMA leakage. When present, leakage types were classified as intradiscal, epidural, foraminal, and perivertebral venous. The frequencies and types of leakages were compared in both groups Using chi(2) and Fisher exact tests, respectively., Results: The PMMA leakage occurred in 20 (55.5%) of 36 fractures with IVCs and in 25 (51.0%) of 49 fractures without IVCs, without significant difference (P = 0.679). No patients experienced clinical complications. The leakage types that frequently occurred were intradiscal (13/20, 65.0%), perivertebral venous (5/20, 25%), epidural (1/20, 5%), and foraminal (1/20, 5%) in compression fractures with IVCs; and epidural (11/25, 44.0%), intradiscal (6/25, 24%), and perivertebral venous (8/25, 32%) in those without. A significant difference was found between the most frequent types in both groups (P = 0.006, P = 0.003, respectively). Conclusions: On CT after vertebroplasty, the incidences of PMMA leakage in osteoporotic compression fractures with and without IVCs were similar; however, leakage type frequencies differed.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 50 条
  • [1] Cement Leakage in Percutaneous Vertebroplasty for Osteoporotic Compression Fractures With or Without Intravertebral Clefts
    Tanigawa, Noboru
    Kariya, Shuji
    Komemushi, Atsushi
    Tokuda, Takanori
    Nakatani, Miyuki
    Yagi, Rie
    Sawada, Satoshi
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : W442 - W445
  • [2] Adjacent Intravertebral Cement Leakage During Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures
    Qin, De-an
    Song, Jie-fu
    Liang, Qing-yuan
    [J]. PAIN MEDICINE, 2021, 22 (06) : 1453 - 1455
  • [3] The impact of intravertebral cleft on cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a case-control study
    Tang, Benqiang
    Xu, Songjie
    Chen, Xueming
    Cui, Libin
    Wang, Yanhui
    Yan, Xin
    Liu, Yadong
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [4] The impact of intravertebral cleft on cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a case-control study
    Benqiang Tang
    Songjie Xu
    Xueming Chen
    Libin Cui
    Yanhui Wang
    Xin Yan
    Yadong Liu
    [J]. BMC Musculoskeletal Disorders, 22
  • [5] Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts
    Ha, K. -Y.
    Lee, J. -S.
    Kim, K. -W.
    Chon, J. -S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05): : 629 - 633
  • [6] Percutaneous Vertebroplasty for Vertebral Compression Fractures with Intravertebral Cleft: Cement Injection under Vacuum Aspiration
    Koike, Yuya
    Takizawa, Kenji
    Ogawa, Yukihisa
    Fujikawa, Atsuko
    Yoshimatsu, Misako
    Nakajima, Yasuo
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (12) : 1721 - 1726
  • [7] The therapeutic effects of percutaneous kyphoplasty on osteoporotic vertebral compression fractures with or without intravertebral cleft
    Li, Zhe
    Liu, Tie
    Yin, Peng
    Wang, Yu
    Liao, Shengen
    Zhang, Shuo
    Su, Qingjun
    Hai, Yong
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (02) : 359 - 365
  • [8] The therapeutic effects of percutaneous kyphoplasty on osteoporotic vertebral compression fractures with or without intravertebral cleft
    Zhe Li
    Tie Liu
    Peng Yin
    Yu Wang
    Shengen Liao
    Shuo Zhang
    Qingjun Su
    Yong Hai
    [J]. International Orthopaedics, 2019, 43 : 359 - 365
  • [9] Percutaneous vertebral augmentation using drill rotation for osteoporotic vertebral compression fractures with intravertebral vacuum cleft
    Li, Min
    Zhang, Yue
    Jin, Peng
    Jia, Pu
    Liu, Xun-wei
    Tang, Hai
    Sun, Gang
    [J]. SKELETAL RADIOLOGY, 2020, 49 (09) : 1459 - 1465
  • [10] Percutaneous vertebral augmentation using drill rotation for osteoporotic vertebral compression fractures with intravertebral vacuum cleft
    Min Li
    Yue Zhang
    Peng Jin
    Pu Jia
    Xun-wei Liu
    Hai Tang
    Gang Sun