Refractive Outcomes of Four-Point Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture

被引:8
|
作者
Patel, Nimesh A. [1 ]
Fan, Kenneth C. [1 ]
Yannuzzi, Nicolas A. [1 ]
Fortun, Jorge A. [1 ]
Haddock, Luis J. [1 ]
Yoo, Sonia H. [1 ]
Persad, Patrice J. [1 ]
Vanner, Elizabeth A. [1 ]
Read, Sarah P. [2 ]
Williams, Basil K., Jr. [1 ,3 ]
Sridhar, Jayanth [1 ]
Albini, Thomas A. [1 ]
Flynn, Harry W., Jr. [1 ]
Donaldson, Kendall [1 ]
Townsend, Justin H. [1 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Dept Ophthalmol, Miller Sch Med, Miami, FL 33136 USA
[2] Retina Consultants Hawaii, Aiea, HI USA
[3] Univ Cincinnati, Coll Med, Dept Ophthalmol, Cincinnati, OH USA
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
Akreos AO60 lens; Gore-Tex; refractive outcomes secondary intraocular lens; scleral fixated IOL; CLINICAL-OUTCOMES; IMPLANTATION;
D O I
10.2147/OPTH.S282094
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/Objective: To determine the refractive outcomes after 4-point scleral fixation of the Akreos AO60 intraocular lens with Gore-Tex suture. Methods: This was a single referral center, multi-surgeon, retrospective consecutive case series. A total of 63 eyes met the inclusion criteria for having received surgical implantation of the Akreos AO60 intraocular lens with Gore-Tex suture from August 2014 to December 2018. Exclusion criteria included all ocular pathology that precluded an accurate refraction, concurrent ocular surgery, poor corrected pre-operative visual potential, among other factors. Main outcome measures included post-operative uncorrected visual acuity (VA), best-corrected VA, and spherical equivalent deviation from target. Results: Mean pre-operative BCVA was 0.67 +/- 0.64 LogMAR (20/93 Snellen). Mean final post-operative BCVA was 0.17 +/- 0.18 (20/28 Snellen) and mean final post-operative UCVA was 0.31 +/- 0.22 (20/41 Snellen). Mean post-operative spherical equivalent was -0.57 D. Mean post-operative astigmatism was 0.85 D. Conclusion: Refractive outcomes after secondary implantation with Akreos AO60 are favorable in eyes with good visual potential.
引用
收藏
页码:4431 / 4437
页数:7
相关论文
共 50 条
  • [1] Scleral Fixation of Akreos AO60 Intraocular Lens Using Gore-Tex Suture: An Eye on Visual Outcomes and Postoperative Complications
    Leuzinger-Dias, Mariana
    Lima-Fontes, Mario
    Rodrigues, Rita
    Oliveira-Ferreira, Claudia
    Madeira, Carolina
    Falcao-Reis, Fernando
    Fernandes, Vitor
    Rocha-Sousa, Amandio
    Falcao, Manuel
    JOURNAL OF OPHTHALMOLOGY, 2021, 2021
  • [2] Refractive Outcomes of Four Point Scleral Fixation of Akreos A060 Intraocular Lens Using Gore-tex Suture
    Fan, Kenneth
    Patel, Nimesh
    Laura, Diana
    Yannuzzi, Nicolas A.
    Williams, Basil K.
    Read, Sarah
    Fortun, Jorge Andres
    Haddock, Luis J.
    Henry, Christopher R.
    Yoo, Sonia H.
    Sridhar, Jayanth
    Albini, Thomas A.
    Donaldson, Kendall
    Flynn, Harry
    Townsend, Justin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [3] Combined 27-Gauge Pars Plana Vitrectomy and Scleral Fixation of an Akreos AO60 Intraocular Lens Using Gore-Tex Suture
    Khan, Mohammed Ali
    Rahimy, Ehsan
    Gupta, Omesh P.
    Hsu, Jason
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (08): : 1602 - 1604
  • [4] Clinical Outcomes of Pars Plana Vitrectomy and Polytetrafluoroethylene (Gore-Tex) Scleral Fixation of a Monofocal Aspheric Intraocular Lens (Akreos AO60)
    Mishra, Amit V.
    Martens, Rosanna
    Loh, Graeme K.
    Somani, Rizwan
    Greve, Mark D. J.
    Seamone, Mark E.
    JOURNAL OF VITREORETINAL DISEASES, 2024, 8 (05) : 540 - 545
  • [5] Four-point subconjunctival scleral fixation technique using Gore-Tex suture
    Lee, Kenneth R. C. K.
    Fung, Adrian T.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (04): : 397 - 399
  • [6] Four-point subconjunctival scleral fixation technique using Gore-Tex suture: Response
    Shah, Yachana
    Shah, Vaibhav
    Raja, Vignesh
    Barrett, Graham D.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (04): : 399 - 400
  • [7] Scleral Fixation of Intraocular Lenses with Gore-Tex Suture Refractive Outcomes and Comparison of Lens Power Formulas
    Botsford, Benjamin W.
    Williams, Andrew M.
    Conner, Ian P.
    Martel, Joseph N.
    Eller, Andrew W.
    OPHTHALMOLOGY RETINA, 2019, 3 (06): : 468 - 472
  • [8] Clinical Results After Scleral Fixation of Akreos A060 Lens Using Gore-Tex suture
    Patel, Nimesh
    Yannuzzi, Nicolas Alessandro
    Kuriyan, Ajay E.
    Flynn, Harry W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] COMBINED PARS PLANA VITRECTOMY AND SCLERAL FIXATION OF AN INTRAOCULAR LENS USING GORE-TEX SUTURE
    Khan, M. Ali
    Samara, Wasim A.
    Gerstenblith, Adam T.
    Chiang, Allen
    Mehta, Sonia
    Garg, Sunir J.
    Hsu, Jason
    Gupta, Omesh P.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (07): : 1377 - 1384
  • [10] Refractive Outcomes after Pars Plana Vitrectomy and Scleral Fixated Intraocular Lens with Gore-Tex Suture
    Su, Daniel
    Stephens, John D.
    Obeid, Anthony
    Borkar, Durga
    Storey, Philip P.
    Khan, M. Ali
    Hsu, Jason
    Garg, Sunir J.
    Gupta, Omesh
    OPHTHALMOLOGY RETINA, 2019, 3 (07): : 548 - 552