Right atrial thrombus due to internal jugular vein catheter

被引:16
|
作者
Ram, Rapur [1 ]
Swarnalatha, Gudithi [1 ]
Rakesh, Yarlagadda [1 ]
Jyostna, Maddury [1 ]
Prasad, Neela [1 ]
Dakshinamurty, Kaligotla Venkata [1 ]
机构
[1] Nizams Inst Med Sci, Hyderabad 082, Andhra Pradesh, India
关键词
Right atrial thrombus; internal jugular vein catheter; pulmonary thromboembolism; anticoagulants; transesophageal echocardiography; CENTRAL VENOUS CATHETERS; SUBCLAVIAN CATHETER; HEMODIALYSIS; COMPLICATION; DIAGNOSIS; INSERTION;
D O I
10.1111/j.1542-4758.2009.00385.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Right atrial thrombus is rare complication of hemodialysis central venous catheter. Literature survey revealed 49 documentations of right atrial thrombus due to a central venous catheter. We report a 58-year-old type 2 diabetic, hypertensive, end-stage renal disease patient, who 2 months after initiation of hemodialysis through a right internal jugular vein catheter, developed clinical features suggestive of pulmonary thromboembolism. An echocardiography revealed presence of a serpentine thrombus in right atrium. The internal jugular vein catheter was removed and unfractionated heparin was initiated. At the end of 6 weeks he was symptom free. We compared conservative treatment with surgery for RAT. Conservative management with central venous catheter removal and anticoagulation therapy is not inferior to the surgery.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 50 条
  • [1] A RIGHT ATRIAL CATHETER AFTER PUNCTURE OF THE INTERNAL JUGULAR VEIN
    SCHAPS, D
    DRANSMANN, F
    OELERT, H
    ANAESTHESIST, 1985, 34 (12): : 688 - 689
  • [2] Right axillary vein thrombosis due to malpositioning of a central venous catheter via the internal jugular vein
    Jang, Ji Su
    Kim, Han Joon
    Yoo, Jae In
    Lee, Jae Jun
    Lim, So Young
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 63 (05) : 479 - 480
  • [3] RIGHT ATRIAL CATHETER INSERTION THROUGH THE EXTERNAL JUGULAR VEIN
    AU, FC
    DEFEO, J
    LIGHTFOOT, WP
    SURGERY GYNECOLOGY & OBSTETRICS, 1979, 149 (05): : 735 - 736
  • [4] Coiling of central venous catheter in right internal jugular vein
    Samra, Tanvir
    Saini, Vikas
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2014, 18 (12)
  • [5] Failure to place a tunneled hemodialysis catheter due to malformation of right internal jugular vein draining to subclavian vein
    Zhu, Li-na
    Mou, Li-jun
    Ying-Hu
    Wei, Gui-na
    Sun, Jun-feng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (06) : 2481 - 2485
  • [6] Catheter-related right internal jugular vein large thrombus formation after inadvertently malposition in the cranial direction
    Wan Ma
    Yuxue Qiu
    Yu Cui
    Guangfei Yang
    Zhitao Wang
    Bin Liu
    Journal of Thrombosis and Thrombolysis, 2019, 48 : 355 - 357
  • [7] Catheter-related right internal jugular vein large thrombus formation after inadvertently malposition in the cranial direction
    Ma, Wan
    Qiu, Yuxue
    Cui, Yu
    Yang, Guangfei
    Wang, Zhitao
    Liu, Bin
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2019, 48 (02) : 355 - 357
  • [8] Misplacement of a central venous catheter into azygos vein via the right internal jugular vein
    Wang, Minjia
    Xu, Liang
    Feng, Yue
    Gong, Shijin
    JOURNAL OF VASCULAR ACCESS, 2021, 22 (06): : 1004 - 1007
  • [9] Pneumatoceles following septicemia due to uncuffed internal jugular vein catheter
    Ram, Rapur
    Swarnalatha, Gudithi
    Rao, Talluri Manmadha
    Rao, Chandanvelli Shyamsundar
    Naidu, Gajjala Diwakar
    Dakshinamurty, Kaligotla Venkata
    HEMODIALYSIS INTERNATIONAL, 2013, 17 (02) : 329 - 330
  • [10] INFUSION HYDROTHORAX DUE TO ABERRANT POSITION OF AN INTERNAL JUGULAR VEIN CATHETER
    HOFFMANN, W
    WEIDMANN, B
    JANSEN, W
    TAUCHERT, M
    MEDIZINISCHE KLINIK, 1988, 83 (15) : 496 - 498