Effects of variations in incident heat flux when using cone calorimeter test data for prediction of full-scale heat release rates of polyurethane foam

被引:7
|
作者
Robson, Luke D. [1 ]
Torvi, David A. [1 ]
Obach, Matthew R. [2 ]
Weckman, Elizabeth J. [2 ]
机构
[1] Univ Saskatchewan, Dept Mech Engn, Saskatoon, SK S7N 5A9, Canada
[2] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
furniture calorimeter; fire testing; cone calorimeter; fire modelling; scaling; polyurethane foam;
D O I
10.1002/fam.2271
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The development of methods to predict full-scale fire behaviour using small-scale test data is of great interest to the fire community. This study evaluated the ability of one model, originally developed during the European Combustion Behaviour of Upholstered Furniture (CBUF) project, to predict heat release rates. Polyurethane foam specimens were tested in the furniture calorimeter using both centre and edge ignition locations. Input data were obtained using cone calorimeter tests and infrared video-based flame area measurements. Two particular issues were investigated: how variations in incident heat flux in cone calorimeter tests impact heat release rate predictions, and the ability of the model to predict results for different foam thicknesses. Heat release rate predictions showed good agreement with experimental results, particularly during the growth phase of the fire. The model was more successful in predicting results for edge ignition tests than for centre ignition tests and in predicting results for thinner foams. Results indicated that because of sensitivity of the burning behaviour to foam specimen geometry and ignition location, a single incident heat flux could not be specified for generating input for the CBUF model. Potential methods to determine appropriate cone calorimeter input for various geometries and ignition locations are discussed. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:89 / 113
页数:25