A new angle stable nailing concept for the treatment of distal tibia fractures

被引:27
|
作者
Kuhn, Sebastian [1 ]
Appelmann, Philipp [1 ]
Pairon, Philip [1 ]
Mehler, Dorothea [1 ]
Hartmann, Frank [1 ]
Rommens, Pol M. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Orthopaed & Traumatol, D-55131 Mainz, Germany
关键词
Distal tibia; Metaphyseal fractures; Intramedullary nailing; Retrograde nailing; Angle Stable Locking System; ANTERIOR KNEE PAIN; METAPHYSEAL FRACTURES; INTRAMEDULLARY NAIL; FIXATION; STABILITY; LOCKING; SHAFT; ETIOLOGY; FEMUR; PLATE;
D O I
10.1007/s00264-013-2267-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Surgical treatment of distal tibial fractures demands a stable fracture fixation while minimizing the irritation to the soft tissues by approach and implant. Biomechanical studies have demonstrated superior performance for angular-stable locked nails over standard locked nails in distal tibial fractures. The experimental Retrograde Tibial Nail (RTN) is a minimally invasive local intramedullary osteosynthesis, which has been under design by our group. We conducted a biomechanical comparison in composite tibiae of the Retrograde Tibial Nail against the Expert Tibial Nail (SynthesA (R)). Our hypothesis was that the RTN would provide equivalent biomechanical stability with respect to extra-axial compression, torsion and load to failure testing, in an extra-articular distal tibia fracture model. Methods Biomechanical composite bone testing was conducted in 14 biomechanical composite tibiae in an AO 43 A3 fracture model. In both groups, triple angle stable interlocking was performed in the distal fragment. Results Results show a statistically non-significant higher stability of the ETN during the axial loading tests. Torsional stability testing resulted in a statistically superior performance for the RTN (p=0.018). Destructive extra-axial compression resulted in failure of six ETN constructs, while all RTN specimens survived the maximal load. Conclusions The experimental Retrograde Tibial Nail provides the key features for the treatment of distal tibial fractures. It combines a minimally invasive local intramedullary osteosynthesis with the ability to securely fix the fracture by multiple angle stable locking options.
引用
收藏
页码:1255 / 1260
页数:6
相关论文
共 50 条
  • [1] A new angle stable nailing concept for the treatment of distal tibia fractures
    Sebastian Kuhn
    Philipp Appelmann
    Philip Pairon
    Dorothea Mehler
    Frank Hartmann
    Pol M. Rommens
    International Orthopaedics, 2014, 38 : 1255 - 1260
  • [2] TREATMENT OF DISTAL TIBIAL FRACTURES BY DUAL NAILING OF TIBIA AND FIBULA
    BORDASSALES, JL
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1976, 62 (08): : 827 - 832
  • [3] Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: A biomechanical study
    Horn, J.
    Linke, B.
    Hoentzsch, D.
    Gueorguiev, B.
    Schwieger, K.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (07): : 767 - 771
  • [4] Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures
    Hoegel, Florian Wolfgang
    Hoffmann, S.
    Weninger, P.
    Buehren, V.
    Augat, P.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (04): : 933 - 938
  • [5] Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
    Sebastian Kuhn
    Philipp Appelmann
    Dorothea Mehler
    Philip Pairon
    Pol M Rommens
    Journal of Orthopaedic Surgery and Research, 9
  • [6] Controversies in the Intramedullary Nailing of Proximal and Distal Tibia Fractures
    Tejwani, Nirmal
    Polonet, David
    Wolinsky, Philip R.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2014, 22 (10) : 665 - 673
  • [7] Retrograde Tibial Nailing: a minimally invasive and biomechanically superior alternative to angle-stable plate osteosynthesis in distal tibia fractures
    Kuhn, Sebastian
    Appelmann, Philipp
    Mehler, Dorothea
    Pairon, Philip
    Rommens, Pol M.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
  • [8] TREATMENT OF DISTAL FRACTURES OF THE TIBIA
    Labronici, Pedro Jose
    Franco, Jose Sergio
    da Silva, Anselmo Fernandes
    de Pina Cabral, Felipe Martins
    Soares, Marcelo da Silva
    de Toledo Lourenco, Paulo Roberto Barbosa
    Hoffmann, Rolix
    Alvachian Fernandes, Helio Jorge
    dos Reis, Fernando Baldy
    ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (01): : 40 - 45
  • [9] Staying Out of Trouble With Intramedullary Nailing of Distal Tibia Fractures
    Lee, Christopher
    Brodke, Dane J.
    Stefanski, James T.
    Gurbani, Ajay
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (02) : E62 - E71
  • [10] The Retrograde Tibial Nail: Presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures
    Kuhn, Sebastian
    Appelmann, Philipp
    Pairon, Philip
    Mehler, Dorothea
    Rommens, Pol M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S81 - S86