High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

被引:784
|
作者
Weis, Dominique
Kieffer, Bruno
Maerschalk, Claude
Barling, Jane
de Jong, Jeroen
Williams, Gwen A.
Hanano, Diane
Pretorius, Wilma
Mattielli, Nadine
Scoates, James S.
Goolaerts, Arnaud
Friedman, Richard M.
Mahoney, J. Brian
机构
[1] Univ British Columbia, Pacific Ctr Isotop & Geochem Res, Dept Earth & Ocean Sci, Vancouver, BC V6T 1Z4, Canada
[2] Univ Libre Bruxelles, Dept Earth & Environm Sci, B-1050 Brussels, Belgium
[3] Univ Wisconsin, Dept Geol, Eau Claire, WI 54702 USA
来源
关键词
MC-ICP-MS; high precision; USGS reference material; Sr-Nd-Pb isotopes; leaching; geochemistry : radiogenic isotope geochemistry; geochemistry : instruments and techniques;
D O I
10.1029/2006GC001283
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
[ 1] The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U. S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods ( e. g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm ( 2 SD) for Sr and Nd isotopic compositions ( 27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions, and concentrations, could be directly related to contamination by the steel (mortar/pestle) used to process the materials. Contamination also accounts for the high concentrations of certain other trace elements ( e. g., Li, Mo, Cd, Sn, Sb, W) in various USGS reference materials.
引用
收藏
页数:30
相关论文
共 50 条
  • [1] High-precision zinc isotopic characterization of twenty soil reference materials from China determined by MC-ICP-MS
    Zhai, Hua-Ye
    Wang, Xuan-Ce
    Li, Chao-Feng
    Wilde, Simon A.
    Li, Xiang-Zhong
    Xu, Bei
    Zhang, Xian-Liang
    Zhang, Ping
    [J]. RSC ADVANCES, 2023, 13 (28) : 19030 - 19038
  • [2] High-precision Sr, Nd, Pb and Hf isotopic characterization of USGS reference materials by MC-ICPMS and TIMS
    Kieffer, B
    Weis, D
    Maerschalk, C
    Barling, J
    Dietrich-Sainsaulieu, E
    Williams, G
    Hanano, D
    Mahoney, JB
    Friedman, RM
    Pretorius, W
    Scoates, JS
    Mattielli, N
    Goolaerts, A
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A794 - A794
  • [3] Emerging applications of high-precision Cu isotopic analysis by MC-ICP-MS
    Sullivan, Kaj V.
    Kidder, James A.
    Junqueira, Tassiane P.
    Vanhaecke, Frank
    Leybourne, Matthew I.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 838
  • [4] Accurate and high-precision measurement of lithium isotopes in two reference materials by MC-ICP-MS
    Millot, R
    Guerrot, C
    Vigier, N
    [J]. GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2004, 28 (01) : 153 - 159
  • [5] High-precision copper isotopic analysis using a Nu Sapphire MC-ICP-MS
    Wang, Jing
    Su, Ben-Xun
    Tang, Dong-Mei
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (12) : 2589 - 2598
  • [6] High-precision lithium isotopic analysis using the Nu Sapphire MC-ICP-MS
    Liu, Shanke
    Li, Wenjun
    Su, Benxun
    Gao, Bingyu
    Wang, Jing
    Wang, Changle
    Luo, Yang
    Yan, Lizhi
    Zhao, Ye
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 656 - 666
  • [7] High precision cadmium isotopic measurements by MC-ICP-MS
    Cloquet, C
    Carignan, J
    Libourel, G
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A144 - A144
  • [8] High-Precision Iron Isotope Analysis of Geological Reference Materials by High-Resolution MC-ICP-MS
    He, Yongsheng
    Ke, Shan
    Teng, Fang-Zhen
    Wang, Tiantian
    Wu, Hongjie
    Lu, Yinhuai
    Li, Shuguang
    [J]. GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2015, 39 (03) : 341 - 356
  • [9] High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS
    Huang, Kuo-Fang
    Blusztajn, Jerzy
    Oppo, Delia W.
    Curry, William B.
    Peucker-Ehrenbrink, Bernhard
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (09) : 1560 - 1567
  • [10] High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS
    Huang, Kuo-Fang
    Blusztajn, Jerzy
    Oppo, Delia W.
    Curry, William B.
    Peucker-Ehrenbrink, Bernhard
    [J]. Journal of Analytical Atomic Spectrometry, 2012, 27 (09): : 1560 - 1567