Axicon lens for high-resolution optical coherence tomography over a long focus depth

被引:1
|
作者
Ding, ZH [1 ]
Ren, HW [1 ]
Zhao, YH [1 ]
Nelson, JS [1 ]
Chen, ZP [1 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
关键词
optical coherence tomography (OCT); axicon lens; focus depth; lateral resolution;
D O I
10.1117/12.470468
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In optical coherence tomography (OCT), axial and lateral resolutions are determined by the source coherence length and numerical aperture of the sampling lens, respectively. While axial resolution can be improved using a broadband light source, there is a trade-off between lateral resolution and focus depth when conventional optical elements are used. In this paper, we report on the incorporation of an axicon lens into the sample arm of the interferometer to overcome this limitation. Using an axicon lens with a top angle of 160 degrees, 10 gm or better lateral resolution is maintained over a focus depth of at least 6 mm. In addition to high lateral resolution, the focusing spot intensity is approximately constant over the whole focus depth.
引用
收藏
页码:10 / 15
页数:6
相关论文
共 50 条
  • [1] High-resolution optical coherence tomography over a large depth range with an axicon lens
    Ding, ZH
    Ren, HW
    Zhao, YH
    Nelson, JS
    Chen, ZP
    [J]. OPTICS LETTERS, 2002, 27 (04) : 243 - 245
  • [2] Optical design of a dynamic focus catheter for high-resolution endoscopic optical coherence tomography
    Meemon, Panomsak
    Lee, Kye-Sung
    Murali, Supraja
    Rolland, Jannick
    [J]. APPLIED OPTICS, 2008, 47 (13) : 2452 - 2457
  • [3] Fourier domain optical coherence tomography with an 800μm diameter axicon lens for long-depth-range probing
    Lee, Kye-Sung
    Koehler, Chuck
    Johnson, Eric G.
    Rolland, Jannick P.
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [4] Extending the depth of focus with high NA lens axicon
    Rajesh, K. B.
    Jaroszewicz, Zbigniew
    Anbarasan, P. M.
    Pillai, T. V. S.
    Suresh, N. Veerabagu
    [J]. OPTIK, 2011, 122 (18): : 1619 - 1621
  • [5] "In Situ" Corneal and Contact Lens Thickness Changes with High-Resolution Optical Coherence Tomography
    Gonzalez-Meijome, Jose M.
    Cervino, Alejandro
    Peixoto-de-Matos, Sofia C.
    Madrid-Costa, David
    Jorge, Jorge
    Ferrer-Blasco, Teresa
    [J]. CORNEA, 2012, 31 (06) : 633 - 638
  • [6] High-resolution optical coherence tomography using a multi-level diffractive lens
    Hamza, Ameer
    Hayward, Tina M.
    Majumder, Apratim
    Brimhall, Nicole
    Menon, Rajesh
    Ha, Jinyong
    [J]. OPTICS EXPRESS, 2024, 32 (16): : 27748 - 27755
  • [7] Near-infrared metalens for high-resolution and deep focus optical coherence tomography
    Haerinia, Mohammad
    Zheng, Bowen
    Hutchins, Aaron
    Tang, Hong
    Li, Hang
    Dong, Yunxi
    Guo, Wei
    Zhang, Hualiang
    [J]. AIP ADVANCES, 2022, 12 (12)
  • [8] Axial resolution and depth range of high-resolution spectral domain optical coherence tomography at 1.3 μm
    Lee, Sang-Won
    Jeong, Hyun-Woo
    Ahn, Yeh-Chan
    Jung, Woonggyu
    Chen, Zhongping
    Kim, Beop-Min
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168
  • [9] High-resolution second harmonic Optical Coherence Tomography
    Jiang, Y
    Tomov, IV
    Wang, YM
    Chen, ZP
    [J]. Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 195 - 200
  • [10] High-resolution extended source optical coherence tomography
    Yu, Xiaojun
    Liu, Xinyu
    Chen, Si
    Luo, Yuemei
    Wang, Xianghong
    Liu, Linbo
    [J]. OPTICS EXPRESS, 2015, 23 (20): : 26399 - 26413