Uric acid-hexacyanoferrate (III)-luminol chemiluminescence system for the determination of trace nitrite

被引:0
|
作者
Gao, Q [1 ]
机构
[1] Henan Agr Univ, Coll Basic Sci, Zhengzhou 450002, Peoples R China
关键词
chemiluminescence; nitrite; uric acid;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In acidic medium that NO2- can oxidize [Fe(CN)(6)](4-) to [Fe(CN)(6)](3-) based on the uric-[Fe(CN)(6)](3-)-luminol chemiluminescence system, the new method for the determination of nitrite was developed. The effect of the concentration of reactionsubstances, acidity, interfering ions etc. on the analytical results was studied. Under optimal conditions, the linear range for the determination of NO2- was 1.0x10(-9)similar to1.0x10(-5) g/mL and the detection limit was 5.0x10(-11) g/mL, the relative standard deviation for the determination of samples (n=11) was 1.8%similar to3.2%. The method is simple, convenience, sensitive and selective. The recovery was between 95.7%similar to105.8%. It was applied to determination of trace nitrite in water and food samples with satisfactory results.
引用
收藏
页码:812 / 814
页数:3
相关论文
共 7 条
  • [1] Bai LS, 2001, CHINESE J ANAL CHEM, V29, P926
  • [2] DENG XL, 1999, ANAL LAB, V18, P63
  • [3] LU J, 1992, CHINESE J ANAL CHEM, V20, P61
  • [4] Lui F., 1987, PHYSICS CHEM ANAL ME, P185
  • [5] WEI FS, 1990, GUIDE ANAL METHOD WA, V1, P156
  • [6] Zhang DJ, 2001, CHINESE J ANAL CHEM, V29, P446
  • [7] ZHOU RG, 1992, CHINESE J ANAL CHEM, V20, P1229