Financial impact of adopting implantable loop recorder diagnostic for unexplained syncope compared with conventional diagnostic pathway in Portugal

被引:6
|
作者
Providencia, Rui [1 ,2 ,9 ]
Candeias, Rui [3 ]
Morais, Carlos [4 ]
Reis, Hipolito [5 ]
Elvas, Luis [1 ]
Sanfins, Vitor [6 ]
Farinha, Sara [7 ]
Eggington, Simon [8 ]
Tsintzos, Stelios [8 ]
机构
[1] Ctr Hosp & Univ Coimbra, Serv Cardiol, Coimbra, Portugal
[2] Univ Coimbra, Fac Med, Coimbra, Portugal
[3] Hosp Faro EPE, Faro, Portugal
[4] Hosp Prof Doutor Fernando da Fonseca EPE, Amadora, Portugal
[5] Ctr Hosp Porto, Hosp Santo Antonio, Oporto, Portugal
[6] Ctr Hosp Alto Ave EPE, Hosp Guimaraes, Guimaraes, Portugal
[7] Medtronic, Lisbon, Portugal
[8] Medtronic, Tolochenaz, Switzerland
[9] Ctr Hosp & Univ Coimbra, Serv Cardiol, Hosp Geral do, P-3041801 Coimbra, Portugal
来源
关键词
Syncope; Implantable loop recorder; Emergency department; Budget impact analysis; TRANSIENT LOSS; GENERAL HOSPITALS; RANDOMIZED ASSESSMENT; CLINICAL-PRACTICE; COST IMPLICATIONS; SINGLE-CENTER; MANAGEMENT; CONSCIOUSNESS; TRIAL; EMERGENCY;
D O I
10.1186/1471-2261-14-63
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To estimate the short-and long-term financial impact of early referral for implantable loop recorder diagnostic (ILR) versus conventional diagnostic pathway (CDP) in the management of unexplained syncope (US) in the Portuguese National Health Service (PNHS). Methods: A Markov model was developed to estimate the expected number of hospital admissions due to US and its respective financial impact in patients implanted with ILR versus CDP. The average cost of a syncope episode admission was estimated based on Portuguese cost data and landmark papers. The financial impact of ILR adoption was estimated for a total of 197 patients with US, based on the number of syncope admissions per year in the PNHS. Sensitivity analysis was performed to take into account the effect of uncertainty in the input parameters (hazard ratio of death; number of syncope events per year; probabilities and unit costs of each diagnostic test; probability of trauma and yield of diagnosis) over three-year and lifetime horizons. Results: The average cost of a syncope event was estimated to be between 1,760 epsilon and 2,800 epsilon . Over a lifetime horizon, the total discounted costs of hospital admissions and syncope diagnosis for the entire cohort were 23% lower amongst patients in the ILR group compared with the CDP group (1,204,621_ for ILR, versus 1,571,332_ for CDP). Conclusion: The utilization of ILR leads to an earlier diagnosis and lower number of syncope hospital admissions and investigations, thus allowing significant cost offsets in the Portuguese setting. The result is robust to changes in the input parameter values, and cost savings become more pronounced over time.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Financial impact of adopting implantable loop recorder diagnostic for unexplained syncope compared with conventional diagnostic pathway in Portugal
    Rui Providência
    Rui Candeias
    Carlos Morais
    Hipólito Reis
    Luís Elvas
    Vitor Sanfins
    Sara Farinha
    Simon Eggington
    Stelios Tsintzos
    [J]. BMC Cardiovascular Disorders, 14
  • [2] FINANCIAL IMPACT OF ADOPTING IMPLANTABLE LOOP RECORDER (ILR) DIAGNOSTICS (REVEAL®) FOR UNEXPLAINED SYNCOPE IN PORTUGAL: COMPARISON WITH CONVENTIONAL DIAGNOSTIC PATHWAYS
    Providencia, R.
    Morais, C.
    Reis, H.
    Elvas, L.
    Candeias, R.
    Sanfins, V
    Farinha, S.
    Tsintzos, S.
    [J]. VALUE IN HEALTH, 2012, 15 (07) : A348 - A348
  • [3] Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
    Solbiati, Monica
    Costantino, Giorgio
    Casazza, Giovanni
    Dipaola, Franca
    Galli, Andrea
    Furlan, Raffaello
    Montano, Nicola
    Sheldon, Robert
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (04):
  • [4] Implantable loop recorder is an effective diagnostic tool for unexplained syncope
    Bovin, Ann
    Malczynski, Jerzy
    Dalsgaard, Dorthe
    [J]. DANISH MEDICAL JOURNAL, 2012, 59 (10):
  • [5] BUDGET IMPACT ANALYSIS OF DIAGNOSTIC OF UNEXPLAINED AND/OR RECURRENT SYNCOPE WITH APPLICATION OF IMPLANTABLE LOOP RECORDER
    Gwiosda, B.
    Palka, I
    Karas, D.
    Wladysiuk, M.
    Szmurlo, D.
    Rutkowski, J.
    Plisko, R.
    Rys, P.
    [J]. VALUE IN HEALTH, 2009, 12 (07) : A322 - A322
  • [6] Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope
    Santilli, Roberto A.
    Ferasin, Luca
    Voghera, Simona G.
    Perego, Manuela
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2010, 236 (01): : 78 - 82
  • [7] Diagnostic usefulness of implantable loop recorder in patients with unexplained syncope or palpitation
    Yun Young Choi
    Jong-Il Choi
    Yun Gi Kim
    Kyongjin Min
    Seung-Young Roh
    Jaemin Shim
    Jin Seok Choi
    Young-Hoon Kim
    [J]. International Journal of Arrhythmia, 23 (1)
  • [8] Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder
    Seidl, K
    Rameken, M
    Breunung, S
    Senges, J
    Jung, W
    Andresen, D
    van Toor, A
    Krahn, AD
    Klein, GJ
    [J]. EUROPACE, 2000, 2 (03): : 256 - 262
  • [9] Additional diagnostic value of very prolonged observation by implantable loop recorder in patients with unexplained syncope
    Maggi, R.
    Furukawa, T.
    Bertolone, C.
    Fontana, D.
    Brignole, M.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 827 - 827
  • [10] Additional Diagnostic Value of Very Prolonged Observation by Implantable Loop Recorder in Patients with Unexplained Syncope
    Furukawa, Toshiyuki
    Maggi, Roberto
    Bertolone, Cristina
    Fontana, Daniele
    Brignole, Michele
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (01) : 67 - 71