A new method for evaluation of patellar height and the position of the joint line before and after total knee arthroplasty

被引:6
|
作者
Han, Hua [1 ,2 ]
Zhang, Xiaohui [1 ,2 ]
机构
[1] Lanzhou Univ, Lanzhou Univ Hosp 2, Dept Orthopaed, 82 Cuiyingmen, Lanzhou 730030, Gansu, Peoples R China
[2] Orthopaed 3D Print Engn Res Ctr Gansu Prov, Lanzhou 730030, Gansu, Peoples R China
关键词
Total knee arthroplasty; Patellar height; Patella baja; Joint line position; Reliability; INSALL-SALVATI RATIO; INTEROBSERVER VARIABILITY; RELIABILITY; RESTORATION; TENDON; LENGTH; BAJA;
D O I
10.1186/s12891-020-03794-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe measurement of patellar height and restoration of the natural position of the joint line are crucial to total knee arthroplasty (TKA). However, there remains a lack of consensus on an optimal measurement method to associate the patellar height with the joint line position. The objective of this study was to introduce a new method and validate the application in TKA both preoperatively and postoperatively.MethodsInstead of taking marginal landmarks as the tibial references, the tibial shaft axis was used to construct the new measurement method, which comprises the axis-patella (AP), joint axis-patella (jAP) indices and joint line height (JLH). Patellar heights were measured using the Insall-Salvati (IS), modified Insall-Salvati (mIS), Blackburne-Peel (BP), Caton-Deschamps (CD) indices, and the new method in 175 knees both preoperatively and postoperatively. Intraclass correlation coefficients and Pearson's correlation analyses were respectively used to evaluate the reliabilities and correlations.ResultsThere were good correlations between the proposed method and the mIS, CD, and BP indices. High inter-observer reproducibility was found for AP (preoperative and postoperative 0.83), jAP (preoperative 0.82; postoperative 0.86) indices and JLH (preoperative 0.88; postoperative 0.95). High intra-observer repeatability was also found for AP (preoperative 0.85; postoperative 0.87), jAP (preoperative 0.83; postoperative 0.87) indices and JLH (preoperative 0.80; postoperative 0.92).ConclusionsThe new method is reliable for measuring patellar height before and after TKA, providing an alternative to distinguish between true and pseudo patella baja. Furthermore, JLH can be applied to assess and restore the joint line position in TKA.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A new method for evaluation of patellar height and the position of the joint line before and after total knee arthroplasty
    Hua Han
    Xiaohui Zhang
    [J]. BMC Musculoskeletal Disorders, 21
  • [2] Joint line and patellar height restoration after revision total knee arthroplasty
    Seon, Jong-Keun
    Song, Eun-Kyoo
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2016, 50 (02) : 159 - 165
  • [3] Joint line and patellar height restoration after revision total knee arthroplasty
    Jong-Keun Seon
    Eun-Kyoo Song
    [J]. Indian Journal of Orthopaedics, 2016, 50 : 159 - 165
  • [4] Patellar height assessment in total knee arthroplasty: a new method
    Jacques H. Caton
    Jean Louis Prudhon
    Thierry Aslanian
    Régis Verdier
    [J]. International Orthopaedics, 2016, 40 : 2527 - 2531
  • [5] Patellar height assessment in total knee arthroplasty: a new method
    Caton, Jacques H.
    Prudhon, Jean Louis
    Aslanian, Thierry
    Verdier, Regis
    [J]. INTERNATIONAL ORTHOPAEDICS, 2016, 40 (12) : 2527 - 2531
  • [6] Patellar Height Changes after Primary Total Knee Arthroplasty
    Drapeau-Zgoralski, Veronique
    Baroudi, Maher
    Benoit, Benoit
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2017, 225 (04) : S144 - S144
  • [7] Plateau-Patella Angle in Evaluation of Patellar Height After Total Knee Arthroplasty
    Robin, Brett N.
    Ellington, Matthew D.
    Jupiter, Daniel C.
    Allen, Bryce C.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (07): : 1394 - 1397
  • [8] Patellar Height After Total Knee Arthroplasty: Comparison of 3 Methods
    Cabral, Filipe
    Sousa-Pinto, Bernardo
    Pinto, Rui
    Torres, Joao
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 552 - +
  • [9] Interobserver variation in the measurement of patellar height after total knee arthroplasty
    Rogers, BA
    Thornton-Bott, P
    Cannon, SR
    Briggs, TWR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (04): : 484 - 488
  • [10] Effects of mal-position of joint line on knee biomechanics after total knee arthroplasty
    Zheng, Hong-Guang
    Huang, Rong-Ying
    Zheng, Hai-Dong
    Zhang, Gao-Long
    [J]. Gongcheng Lixue/Engineering Mechanics, 2013, 30 (SUPPL.1): : 298 - 303