Comparison between pinch analysis and bridge analysis to retrofit the heat exchanger network of a kraft pulp mill

被引:40
|
作者
Bonhivers, J. C. [1 ]
Svensson, E. [2 ]
Berntsson, T. [2 ]
Stuart, P. R. [1 ]
机构
[1] Ecole Polytech Montreal, Dept Chem Engn, NSERC Design Engn Chair Proc Integrat, Montreal, PQ, Canada
[2] Chalmers, S-41296 Gothenburg, Sweden
关键词
Process integration; Heat-exchanger network; Retrofit; Energy savings; OPTIMIZATION; MODEL; INTEGRATION; DESIGN;
D O I
10.1016/j.applthermaleng.2014.04.052
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pinch analysis is based on the hot, cold and grand composite curves and is the most commonly-used approach to identify strategies for reducing energy consumption by heat exchanger network retrofit. This method was originally developed for the synthesis of new networks, and there remain certain difficulties for its application to improve existing networks. The advanced composite curves have been developed for retrofit situations specifically, and use data about existing heat exchangers to provide more information about the modifications necessary to achieve heat savings. Bridge analysis, which is based on the energy transfer diagram, is a new method and enumerates the sets of heat transfer modifications necessary to save energy. In this paper, the grand composite curve, the advanced composite curves and the energy transfer diagram have been constructed for analysis of the heat exchanger network of a kraft pulp mill. Links between these methods are made explicit; then results are discussed and compared. It is shown that the information provided by these approaches is consistent; however, the level of detail progressively increases from the grand composite curve to the advanced composite curves until the energy transfer diagram. Fundamentally, reducing the energy consumption implies decreasing the flow rate of heat cascaded through the network from the hot utility until the environment. As a consequence, any heat savings solution includes network modifications bridging coolers to heaters. Traditional pinch analysis does not provide information about the network modifications required after removal of cross pinch transfers, while the advanced composite curves indicate the heat savings potential attainable through modifications of few existing heat exchanger units. Bridge analysis provides more detail about heat savings modifications, which bridge existing heaters and coolers, than traditional pinch analysis and the advanced composite curves do. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:369 / 379
页数:11
相关论文
共 50 条
  • [1] Improving the network pinch approach for heat exchanger network retrofit with bridge analysis
    Bonhivers, Jean-Christophe
    Moussavi, Alireza
    Hackl, Roman
    Sorin, Mikhail
    Stuart, Paul R.
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2019, 97 (03): : 687 - 696
  • [2] Linking pinch analysis and bridge analysis to save energy by heat-exchanger network retrofit
    Bonhivers, Jean-Christophe
    Moussavi, Alireza
    Alva-Argaez, Alberto
    Stuart, Paul R.
    [J]. APPLIED THERMAL ENGINEERING, 2016, 106 : 443 - 472
  • [3] Heat Exchanger Network Retrofit of Diesel Hydrotreating Unit Using Pinch Analysis
    Sun Mengying
    Zhang Fengjiao
    Liu Xinglong
    Sun Lanyi
    [J]. CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2021, 23 (02) : 34 - 43
  • [4] Heat Exchanger Network Retrofit of Diesel Hydrotreating Unit Using Pinch Analysis
    Sun Mengying
    Zhang Fengjiao
    Liu Xinglong
    Sun Lanyi
    [J]. China Petroleum Processing & Petrochemical Technology, 2021, 23 (02) : 34 - 43
  • [5] Heat Exchanger Network Retrofit for Optimization of Crude Distillation Unit Using Pinch Analysis
    Sun Mengying
    Fu Dianliang
    Sun Lanyi
    [J]. China Petroleum Processing & Petrochemical Technology, 2021, 23 (01) : 31 - 40
  • [6] Heat Exchanger Network Retrofit for Optimization of Crude Distillation Unit Using Pinch Analysis
    Mengying, Sun
    Dianliang, Fu
    Lanyi, Sun
    [J]. CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2021, 23 (01) : 31 - 40
  • [7] Linking pinch analysis and shifted temperature driving force plot for analysis and retrofit of heat exchanger network
    Fu, Dianliang
    Yu, Zeting
    Lai, Yanhua
    [J]. JOURNAL OF CLEANER PRODUCTION, 2021, 315
  • [8] A new graphical method for Pinch Analysis applications: Heat exchanger network retrofit and energy integration
    Gadalla, Mamdouh A.
    [J]. ENERGY, 2015, 81 : 159 - 174
  • [9] Optimization Heat Transfer Coefficient in Retrofit Heat Exchanger Network Using Pinch Analysis and Killer Whale Algorithm
    Biyanto, Totok Ruki
    Tama, Nanda E.
    Permatasari, Inesya
    Sabillah, Muhammad G.
    Napitupulu, David H.
    Anda, Ahmad R.
    [J]. ADVANCED INDUSTRIAL TECHNOLOGY IN ENGINEERING PHYSICS, 2019, 2088
  • [10] Energy Analysis for Conversion of a Kraft Pulp Mill into a Dissolving Pulp Mill
    Lundberg, Valeria
    Axelsson, Erik
    Mahmoudkhani, Maryam
    Berntsson, Thore
    [J]. PRES 2012: 15TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2012, 29 : 13 - 18