Experimental and Theoretical Study of Surge Behavior in a Boil-Off Gas Centrifugal Compressor on an LNG Carrier

被引:0
|
作者
Lee, Jinkwang [1 ]
Cheon, Yujin [2 ]
Choi, Younseok [3 ]
机构
[1] Dong A Univ, Dept Naval Architecture & Offshore Engn, 37 Nakdong Daero 550 Beon Gil, Busan 49315, South Korea
[2] Kyungpook Natl Univ, Dept Chem Sci & Engn, 80 Daehak Ro, Daegu 41566, South Korea
[3] Republ Korea Air Force Acad, Dept Aerosp Engn, 635 Danjae Ro, Cheongju 28187, South Korea
关键词
surge; industrial-scale centrifugal compressor; lumped-parameter model; Greitzer model; AXIAL-FLOW COMPRESSORS; POST-STALL TRANSIENTS; ROTATING STALL; SYSTEMS;
D O I
10.3390/en15114002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, we conducted experiments and numerical analysis on a 270 kW industrial-scale centrifugal compressor used in the fuel supply system of an LNG carrier in order to improve the lumped-parameter surge model by considering the viscosity in the pipeline and to confirm whether the improved model would be applicable. The steady and unsteady compressor performance curves were constructed using measurements and predictions, respectively. The flow through the pipeline was assumed to be both steady and unsteady, and each governing equation under the assumptions was derived in accordance with the lumped-parameter model. In the steady flow case, the surge behavior of the modified model was in a good agreement with the lumped-parameter model at surge parameter B = 4.8716. In the unsteady flow case, however, the modified model showed a deviation from the lumped-parameter model, and the simulation from the modified model described the surge behavior 5% more accurately than the lumped-parameter model. Through experiments and numerical analysis, this study showed that the present models are useful and applicable for describing the surge behavior of an industrial-scale single-stage centrifugal compressor.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Seismic performance evaluation of boil-off gas compressor in LNG terminal
    Park, Hyo-Sang
    Lee, Tae-Hyung
    Open Civil Engineering Journal, 2015, 9 (01): : 557 - 569
  • [2] OUTLOOK OF ULTRA LOW TEMPERATURE LNG BOIL-OFF GAS COMPRESSOR.
    Kawakami, Akira
    Kanetaka, Isamu
    IHI Engineering Review (English Edition), 1984, 17 (03): : 170 - 176
  • [3] Utilization of Engine Exhaust Gas in Boil-off Gas Reliquefaction System of a LNG Carrier Ship
    Kochunni, Sarun Kumar
    Chowdhury, Kanchan
    15TH CRYOGENICS 2019 IIR INTERNATIONAL CONFERENCE, 2019, : 254 - 261
  • [4] BOIL-OFF GAS VAPORS ARE RECOVERED BY RELIQUEFACTION IN LNG
    LERAY, M
    PETIT, P
    PARADOWSKI, H
    OIL & GAS JOURNAL, 1986, 84 (08) : 58 - 62
  • [5] Outlook for LNG boil-off gas reciprocating compressors
    Miyamoto, T.
    Abe, M.
    Ishikawajima-Harima Giho/IHI Engineering Review, 1996, 36 (06): : 483 - 489
  • [6] A thermal and thermodynamic code for the computation of Boil-Off Gas - Industrial applications of LNG carrier
    Qu, Yongfeng
    Noba, Ibrahima
    Xu, Xiaochun
    Privat, Romain
    Jaubert, Jean-Noel
    CRYOGENICS, 2019, 99 : 105 - 113
  • [7] Greenhouse Gas Reduction by Utilization of Cold LNG Boil-off Gas
    Zakaria, Mohamad Shukri
    Osman, Kahar
    Abdullah, Haslina
    MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING & TECHNOLOGY 2012 (MUCET 2012), 2013, 53 : 645 - 649
  • [8] Optimal operation of the boil-off gas compression process using a boil-off rate model for LNG storage tanks
    Myung Wook Shin
    Dongil Shin
    Soo Hyoung Choi
    En Sup Yoon
    Korean Journal of Chemical Engineering, 2008, 25 : 7 - 12
  • [9] Optimize LNG boil-off gas systems for regasification terminals
    Zolfkhani, M.
    HYDROCARBON PROCESSING, 2013, 92 (01): : 37 - 39