Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging

被引:27
|
作者
Zeniya, Tsutomu
Watabe, Hiroshi
Aoi, Toshiyuki
Kim, Kyeong Min
Teramoto, Noboru
Takeno, Takeshi
Ohta, Yoichiro
Hayashi, Takuya
Mashino, Hiroyuki
Ota, Toshihiro
Yamamoto, Seiichi
Iida, Hidehiro
机构
[1] Natl Cardiovasc Ctr, Res Inst, Adv Med Engn Ctr, Dept Invest Radiol, Osaka 5658565, Japan
[2] Korea Inst Radiol & Med Sci, Radiol & Med Sci Res Ctr, Nucl Med Lab, Seoul, South Korea
[3] Kobe City Coll Technol, Dept Elect Engn, Kobe, Hyogo, Japan
关键词
SPECT; pinhole collimator; compact pixellated gamma camera; small animal;
D O I
10.1007/BF03027376
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera fitted to a pinhole collimator and an object-rotating unit. This study was aimed at evaluating the basic performance of the detection system and the feasibility of small animal SPECT imaging. Methods: The gamma camera consists of a 22 x 22 pixellated scintillator array of 1.8 mm x 1.8 mm x 5 mm NaI(Tl) crystals with 0.2-mm gap between the crystals coupled to a 2" flat panel position-sensitive photomultiplier tube (Hamamatsu H8500) with 64 channels. The active imaging region of the camera was 43.8 mm x 43.8 mm. Data acquisition is controlled by a personal computer (Microsoft Windows) through the camera controller. Projection data over 360 degrees for SPECT images are obtained by synchronizing with the rotating unit. The knife-edge pinhole collimators made of tungsten are attached on the camera and have 0.5-mm and 1.0-mm apertures. The basic performance of the detection system was evaluated with Tc-99m and Tl-201 solutions. Energy resolution, system spatial resolution and linearity of count rate were measured. Rat myocardial perfusion SPECT scans were sequentially performed following intravenous injection of 201 TlCl. Projection data were reconstructed using a previously validated pinhole 3D-OSEM method. Results: The energy resolution at 140 keV was 14.8% using a point source. The system spatial resolutions were 2.8-mm FWHM and 2.5-mm FWHM for Tc-99m and Tl-201 line sources, respectively, at 30-mm source distance (magnification factor of 1.3) using a 1.0-mm pinhole. The linearity between the activity and count rate was good up to 10 kcps. In a rat study, the left ventricular walls were clearly visible in all scans. Conclusions: We developed a compact SPECT system using compact gamma camera for small animals and evaluated basic physical performances. The present system may be of use for quantitation of biological functions such as myocardial blood flow in small animals.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 50 条
  • [1] Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging
    Tsutomu Zeniya
    Hiroshi Watabe
    Toshiyuki Aoi
    Kyeong Min Kim
    Noboru Teramoto
    Takeshi Takeno
    Yoichiro Ohta
    Takuya Hayashi
    Hiroyuki Mashino
    Toshihiro Ota
    Seiichi Yamamoto
    Hidehiro Iida
    [J]. Annals of Nuclear Medicine, 2006, 20 : 409 - 416
  • [2] A review of small animal imaging planar and pinhole spect Γ camera imaging
    Peremans, K
    Cornelissen, B
    Van den Bossche, B
    Audenaert, K
    Van de Wiele, C
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (02) : 162 - 170
  • [3] Optimized collimator designs for small animal SPECT imaging with a compact gamma camera
    Qi, Yujin
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1780 - 1782
  • [4] rSPECT: A Compact Gamma Camera Based SPECT System for Small-Animal Imaging
    Lage, Eduardo
    Villena, Jose L.
    Tapias, Gustavo
    Vidal-Migallon, I.
    Abella, Monica
    Sisniega, Alejandro
    Martinez, Naira P.
    Ros, Domenec
    Desco, Manuel
    Vaquero, Juan J.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3126 - 3131
  • [5] On the Use of Asymmetrical Pinhole Collimators for Small Animal SPECT Imaging
    Peter, J.
    Ruehle, H.
    Stamm, V.
    Semmler, W.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S254 - S254
  • [6] A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging
    Mejia, J.
    Galvis-Alonso, O. Y.
    de Castro, A. A.
    Braga, J.
    Leite, J. P.
    Simoes, M. V.
    [J]. BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2010, 43 (12) : 1160 - 1166
  • [7] Small animal imaging with multi-pinhole SPECT
    Nuyts, Johan
    Vunckx, Kathleen
    Defrise, Michel
    Vanhove, Christian
    [J]. METHODS, 2009, 48 (02) : 83 - 91
  • [8] Characterization of imaging gamma detectors for use in small animal SPECT
    Stolin, AV
    Williams, MB
    Kundu, BK
    Majewski, S
    Popov, V
    Weisenberger, AG
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2085 - 2089
  • [9] HIGH-RESOLUTION PINHOLE SPECT FOR SMALL ANIMAL IMAGING
    ERLANDSSON, K
    IVANOVIC, M
    STRAND, SE
    SJOGREN, K
    WEBER, DA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05): : P9 - P9
  • [10] Finite aperture modeling in small animal pinhole SPECT Imaging
    Huang, PC
    Hsu, CH
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3454 - 3457