Determination of 11-deoxycortisol (Reichstein's compound S) in human plasma by clinical isotope dilution mass spectrometry using benchtop gas chromatography-mass selective detection

被引:17
|
作者
Wudy, SA
Hartmann, M
Homoki, J
机构
[1] Univ Giessen, Steroid Res Unit, Childrens Hosp, Steroid Lab, D-35392 Giessen, Germany
[2] Univ Ulm, Childrens Hosp, Steroid Lab, Ulm, Germany
关键词
gas chromatography; mass spectrometry; steroid; 11-deoxycortisol; compound S; stable isotope;
D O I
10.1016/S0039-128X(02)00052-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A first assay based on stable isotope dilution/gas chromatography-mass spectrometry (ID/GC-MS) has been developed for plasma 11-deoxycortisol (Reichstein's compound S), the leading hormonal marker of 11beta-hydroxylase deficiency. A suitable internal standard being unavailable, we synthesized dideuterated 11-deoxycortisol according to a newly devised synthetic procedure. 17,21-Dihydroxy-pregna-1,4-diene-3,20-dione underwent selective deuteration using Wilkinson's catalyst. Our product [1alpha,2alpha-H-2(2)]11-deoxycortisol was obtained in good yield (35.6%) and high isotopic purity (0.1% H-2(0), 99.9% H-2(2)). Structural confirmation was done by MS and NMR. Our plasma work up consisted of equilibration of plasma with internal standard ([1alpha,2alpha-H-2(2)]11-deoxyconisol), solid phase extraction with Extrelut(R) NT columns, a clean up step using Sephadex LH-20 mini columns and preparation of heptafluorobutyrates as derivatives. Quantification was achieved by selected ion monitoring of m/z 465.40 (analyte) and m/z 467.40 (internal standard). One hundred twenty picograms of 11-deoxycortisol gave a signal to noise ratio of 10. Calibration plot was linear. Spiking experiments showed good accuracy with relative errors <3.0%. Intraassay precision CV was 4.78% and interassay precision CV was 4.56%. We succeeded in integrating our new analyte into our already existing multisteroid ID/GC-MS plasma assay, which now, in its expanded version, is capable of determining all major diagnostic steroids of androgen related disorders in a single profile: 11-deoxycortisol, 17alpha-hydroxyprogesterone, testosterone, 4-androstenedione, 17alpha-hydroxypregnenolone, dehydroepiandrosterone, androstanediol and 5alpha-dihydrotestosterone. The diagnostic potential of our multisteroid ID/GC-MS assay, the small amounts of plasma (0.5 ml) required, the rapid and convenient sample work up, the application of benchtop GC-MS instrumentation, and highest specificity offered by mass spectrometric detection prove our assay suitable for routine clinical use, especially in pediatric endocrinology. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 50 条
  • [1] Determination of 17α-hydroxypregnenolone in human plasma by routine isotope dilution mass spectrometry using benchtop gas chromatography-mass selective detection
    Wudy, SA
    Hartmann, M
    Solleder, C
    Homoki, J
    STEROIDS, 2001, 66 (10) : 759 - 762
  • [2] Profiling oestrogens and testosterone in human urine by stable isotope dilution/benchtop gas chromatography-mass spectrometry
    Hoffmann, Philipp
    Hartmann, Michaela F.
    Remer, Thomas
    Zimmer, Klaus-Peter
    Wudy, Stefan A.
    STEROIDS, 2010, 75 (13-14) : 1067 - 1074
  • [3] Simultaneous determination of serine enantiomers in plasma using Mosher's reagent and stable isotope dilution gas chromatography-mass spectrometry
    Hasegawa, Hiroshi
    Shinohara, Yoshihiko
    Masuda, Nami
    Hashimoto, Takao
    Ichida, Kimiyoshi
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (05): : 502 - 507
  • [4] Determination of plasma N-tau-methylhistamine in vivo by isotope dilution using benchtop gas chromatography mass spectrometry
    Tredget, EE
    Iwashina, T
    Scott, PG
    Ghahary, A
    JOURNAL OF CHROMATOGRAPHY B, 1997, 694 (01): : 1 - 9
  • [5] Determination of endogenous agmatine in rat plasma by isotope dilution-gas chromatography-mass spectrometry
    Qiu Zhongli
    Lin Ying
    Xiong Zhili
    Xie Jianwei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (07) : 779 - 783
  • [6] Galactonate determination in urine by stable isotope dilution gas chromatography-mass spectrometry
    Schadewaldt, P
    Hammen, HW
    Stolpmann, S
    Kamalanathan, L
    Wendel, U
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 801 (02): : 249 - 255
  • [7] Determination of cyanide in blood by isotope-dilution gas chromatography-mass spectrometry
    Murphy, KE
    Schantz, MM
    Butler, TA
    Benner, BA
    Wood, LJ
    Turk, GC
    CLINICAL CHEMISTRY, 2006, 52 (03) : 458 - 467
  • [8] SIMULTANEOUS ANALYSIS OF 11-DEOXYCORTISOL, 17-HYDROXYPROGESTERONE AND CORTISOL BY LIQUID CHROMATOGRAPHY-ISOTOPE DILUTION TANDEM MASS SPECTROMETRY
    Wan, B.
    Yazdanpanah, M.
    Adeli, K.
    Kyriakopoulou, G. L.
    MOLECULAR GENETICS AND METABOLISM, 2009, 98 (1-2) : 108 - 108
  • [9] Validation of a method for the determination of plasma total homocysteine by gas chromatography-mass spectrometry with stable isotope dilution
    Belkhiria, MN
    Hammami, S
    Chraef, I
    Mahjoub, S
    Hammami, M
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 239 - 242
  • [10] Gas chromatography-mass spectrometry determination of matrine in human plasma
    Sit, DST
    Gao, GH
    Law, FCP
    Li, PCH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02): : 209 - 214