Immobilization of glucose oxidase on the films prepared by electrochemical copolymerization of pyrrole and 1-(2-carboxyethyl)pyrrole for glucose sensing
被引:30
|
作者:
Shimomura, Masato
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, Japan
Shimomura, Masato
[1
]
Miyata, Ryo
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, Japan
Miyata, Ryo
[1
]
Kuwahara, Takashi
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, Japan
Kuwahara, Takashi
[1
]
Oshima, Kenji
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, Japan
Oshima, Kenji
[1
]
Miyauchi, Shinnosuke
论文数: 0引用数: 0
h-index: 0
机构:
Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, JapanNagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, Japan
Miyauchi, Shinnosuke
[1
]
机构:
[1] Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Nagaoka, Niigata 9402188, Japan
Glucose oxidase (GOx) was immobilized through amide linkages on the surfaces of the conducting polymer films prepared by electrochemical copolymerization of pyrrole (Py) and 1-(2-carboxyethyl)pyrrole (Py-COOH) for the purpose of fabricating GOx-immobilized electrodes for amperometric sensing of glucose. The conductivity of the copolymer film was in the range 10(-8)-10(-3) S/cm and showed a tendency to decrease with increasing content of Py-COOH units in the copolymer. The amount of immobilized GOx increased significantly with increasing content of Py-COOH units in the copolymer film up to 30%, and showed a tendency to level off when the content of Py-COOH units became larger. The activity of immobilized GOx per area of the copolymer film decreased slightly with increasing content of Py-COOH units in the copolymer. Although the GOx-immobilized copolymer films gave the amperometric response to glucose depending on its concentration, the magnitude of the response to a given concentration was found to decrease with increasing content of Py-COOH units in the copolymer. The variation in the amperometric response was attributed to the difference in conductivity of the copolymer film. The appropriate content of Py-COOH units in the copolymer was considered to be 5% or less for the amperometric sensing of glucose with the GOx-immobilized copolymer film. (c) 2006 Elsevier Ltd. All rights reserved.
机构:
Daejin Univ, Dept Mat Sci & Engn, Pochun Si 487711, Kyunggi Do, South KoreaDaejin Univ, Dept Mat Sci & Engn, Pochun Si 487711, Kyunggi Do, South Korea
Sung, YM
Park, KS
论文数: 0引用数: 0
h-index: 0
机构:Daejin Univ, Dept Mat Sci & Engn, Pochun Si 487711, Kyunggi Do, South Korea
Park, KS
Lee, YJ
论文数: 0引用数: 0
h-index: 0
机构:Daejin Univ, Dept Mat Sci & Engn, Pochun Si 487711, Kyunggi Do, South Korea
Lee, YJ
Chae, WS
论文数: 0引用数: 0
h-index: 0
机构:Daejin Univ, Dept Mat Sci & Engn, Pochun Si 487711, Kyunggi Do, South Korea
Chae, WS
Song, YW
论文数: 0引用数: 0
h-index: 0
机构:Daejin Univ, Dept Mat Sci & Engn, Pochun Si 487711, Kyunggi Do, South Korea