Additional value of three-dimensional echocardiography in patients with cardiac resynchronization therapy

被引:9
|
作者
Deplagne, Antoine [2 ]
Bordachar, Pierre [1 ,2 ]
Reant, Patricia [1 ,2 ]
Montaudon, Michel [2 ]
Reuter, Sylvain [2 ]
Laborderie, Julien [2 ]
Dos Santos, Pierre [1 ]
Roudaut, Raymond [2 ]
Jais, Pierre [2 ]
Haissaguerre, Michel [2 ]
Laurent, Francois [2 ]
Clementy, Jacques [2 ]
Lafitte, Stephane [1 ,2 ]
机构
[1] Univ Bordeaux 2, F-33076 Bordeaux, France
[2] CHU Bordeaux, Bordeaux, France
关键词
Cardiac resynchronization therapy; Echocardiography; Dyssynchrony; 3-dimensionnal; CONGESTIVE-HEART-FAILURE; DOPPLER; DYSSYNCHRONY; PREDICTS; PARAMETERS; ASYNCHRONY; BENEFIT;
D O I
10.1016/j.acvd.2009.03.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - There is no gold standard technique for quantification of ventricular dyssynchrony. Aim. - To investigate whether additional real-time three-dimensional morphologic assessment of ventricular dyssynchrony affects response after biventricular pacing. Methods. - Forty-one patients with severe heart failure were implanted with a biventricular pacing device and underwent two-dimensional (time dispersion of 12 left ventricular electromechanical delays) and three-dimensional echocardiographic assessment of ventricular dyssynchrony (dispersion of time to minimum regional volume for 16 left ventricular segments), before implantation, 2 days postimplantation with optimization of the pacing interventricular delay and 6 months postimplantation. Results. - Individual optimization of sequential biventricular pacing based on three-dimensional ventricular dyssynchrony provided more improvement (p < 0.05) in left ventricular ejection fraction and cardiac output than simultaneous biventricular pacing. During the different configurations of sequential biventricular pacing, the changes in three-dimensional ventricular dyssynchrony were highly correlated with those of cardiac output (r = -0.67, p < 0.001) and ejection fraction (r = -0.68, p<0.001). The correlations between two-dimensional ventricular dyssynchrony and cardiac output or ejection fraction were significant but less (r = -0.60, p < 0.01 and r = -0.56, p < 0.05, respectively). After 6 months, 76% of patients were considered responders (10% decrease in end-systolic volume). Before implantation, we observed a significant difference between responders and non-responders in terms of three-dimensional (p < 0.05) - but not two-dimensional - ventricular dyssynchrony. Conclusion. - This prospective study demonstrated the additional value of three-dimensional assessment of ventricular dyssynchrony in predicting response after biventricular pacing and optimizing the pacing configuration. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:497 / 508
页数:12
相关论文
共 50 条
  • [1] Three-dimensional echocardiography for optimization of cardiac resynchronization therapy
    Ballo, Piercarlo
    Motto, Andrea
    Mondillo, Sergio
    Galderisi, Maurizio
    EUROPEAN HEART JOURNAL, 2009, 30 (04) : 505 - 505
  • [2] Assessment of left ventricular dyssynchrony by three-dimensional echocardiography: Prognostic value in patients undergoing cardiac resynchronization therapy
    Hoke, Ulas
    Bax, Jeroen J.
    Delgado, Victoria
    Marsan, Nina Ajmone
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (05) : 780 - 787
  • [3] Utility of three-dimensional echocardiography in assessing and predicting response to cardiac resynchronization therapy
    Lau, Ching
    Abdel-Qadir, Husam M.
    Lashevsky, Ilan
    Hansen, Mark
    Crystal, Eugene
    Joyner, Campbell
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 (09) : 475 - 480
  • [4] Utility of three-dimensional echocardiography in assessing and predicting response to cardiac resynchronization therapy
    Lau, Ching
    Hansen, Mark
    Lashevsky, Ilan
    Crystal, Eugene
    Joyner, Campbell
    CIRCULATION, 2007, 116 (16) : 554 - 554
  • [5] Three-dimensional Imaging in Cardiac Resynchronization Therapy
    Auger, Dominique
    Schalij, Martin J.
    Bax, Jeroen J.
    Delgado, Victoria
    REVISTA ESPANOLA DE CARDIOLOGIA, 2011, 64 (11): : 1035 - 1044
  • [6] Prognostic value of global tangential strain by three-dimensional echocardiography heart failure patients with intermediate ECG criteria for cardiac resynchronization therapy
    Sugahara, M.
    Ashida, K.
    Fukuhara, E.
    Kishima, H.
    Goda, A.
    Mine, T.
    Ishihara, M.
    Masuyama, T.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3655 - 3655
  • [7] Real Time Three-Dimensional Echocardiography in Assessment of Left Ventricular Dyssynchrony and Cardiac Resynchronization Therapy
    Wang, Haojie
    Shuraih, Mossaab
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (02): : 192 - 199
  • [8] Real-time three-dimensional echocardiography predicts acute response to cardiac resynchronization therapy
    Marsan, N. Ajmone
    Bleeker, G. B.
    Ypenburg, C.
    Van de Veire, N. R.
    Holman, E. R.
    Van der Wall, E. E.
    Schalij, M. J.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2007, 28 : 295 - 295
  • [9] Visualization of cardiac resynchronization using real-time three-dimensional echocardiography
    Burri, H
    Lerch, R
    HEART RHYTHM, 2005, 2 (04) : 447 - 448
  • [10] Utility of three-dimensional echocardiography (3DE) in assessing and predicting response to cardiac resynchronization therapy (CRT)
    Lau, C.
    Hansen, M.
    Crystal, E.
    Lashevsky, I.
    Joyner, C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 168C - 168C