Recalibration of a gas-sensor array system related to sensor replacement

被引:31
|
作者
Tomic, O
Eklöv, T
Kvaal, K
Haugen, JE
机构
[1] Norwegian Food Res Inst, MATFORSK, N-1430 As, Norway
[2] Swedish Def Res Agcy, S-58111 Linkoping, Sweden
[3] Agr Univ Norway, NLH, N-1430 As, Norway
关键词
electronic nose; gas-sensor array; sensor replacement; recalibration; multiplicative drift correction; component correction;
D O I
10.1016/j.aca.2004.03.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Univariate multiplicative drift correction and multivariate component correction were applied for recalibration of long-term measurement data acquired with a solid-state gas-sensor array system. The efficiency of the methods was evaluated by classifying recalibrated measurement data using k-nearest neighbor classification and partial least-squares discriminant analysis. For the measurement data in this experiment both multiplicative drift correction and component correction appeared to be useful for recalibration of measurement data from the new gas-sensor array with regard to measurement data acquired with the old replaced gas-sensor array. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [1] Detection of mastitic milk using a gas-sensor array system (electronic nose)
    Eriksson, Å
    Waller, KP
    Svennersten-Sjaunja, K
    Haugen, JE
    Lundby, F
    Lind, O
    [J]. INTERNATIONAL DAIRY JOURNAL, 2005, 15 (12) : 1193 - 1201
  • [2] METHOD FOR MONITORING SENSOR STABILITY IN A MULTIPLE SEMICONDUCTOR GAS-SENSOR SYSTEM
    ABE, H
    KANAYA, S
    TAKAHASHI, Y
    SASAKI, S
    [J]. ANALYTICA CHIMICA ACTA, 1989, 225 (01) : 89 - 96
  • [3] Standardization methods for handling instrument related signal shift in gas-sensor array measurement data
    Tomic, O
    Ulmer, H
    Haugen, JE
    [J]. ANALYTICA CHIMICA ACTA, 2002, 472 (1-2) : 99 - 111
  • [4] Polyaniline as a gas-sensor material
    Sengupta, Partha Pratim
    Barik, Satyananda
    Adhikari, Basudam
    [J]. MATERIALS AND MANUFACTURING PROCESSES, 2006, 21 (03) : 263 - 270
  • [5] Detection of rancidity in freeze stored turkey meat using a commercial gas-sensor array system
    Haugen, John-Erik
    Lundby, Frank
    Wold, Jens Petter
    Veberg, Annette
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 116 (1-2) : 78 - 84
  • [6] Spherical gas-sensor array for three-dimensional plume tracking
    Ishida, H
    Tsuruno, M
    Yoshikawa, K
    Moriizumi, T
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS 2003, VOL 1-3, 2003, : 369 - 374
  • [7] Analytical investigations of gas-sensor using methane decomposition system
    Elnaz Akbari
    Zolkafle Buntat
    Abdolkarim Afroozeh
    Alireza Zeinalinezhad
    M. J. Kiani
    M. H. Shahrokh Abadi
    [J]. Environmental Earth Sciences, 2016, 75
  • [8] Analytical investigations of gas-sensor using methane decomposition system
    Akbari, Elnaz
    Buntat, Zolkafle
    Afroozeh, Abdolkarim
    Zeinalinezhad, Alireza
    Kiani, M. J.
    Abadi, M. H. Shahrokh
    [J]. ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (05) : 1 - 10
  • [9] ITO Nanowires for Gas-Sensor Applications
    Afshar, M.
    Preiss, E.
    Sauerwald, T.
    Feili, D.
    Seidel, H.
    [J]. 2013 8TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE NEMS 2013), 2013, : 1123 - 1126
  • [10] MEMS gas-sensor array for monitoring the perceived car-cabin air quality
    Blaschke, Michael
    Tille, Thomas
    Robertson, Phil
    Mair, Stefan
    Weimar, Udo
    Ulmer, Heiko
    [J]. IEEE SENSORS JOURNAL, 2006, 6 (05) : 1298 - 1308