Thermal-hydraulic analyses of passive reactor vault cooling system (RVCS) in PGSFR using MARS-LMR

被引:9
|
作者
Choi, Chiwoong [1 ]
Jeong, Taekyeong [1 ]
An, Sangjun [1 ]
机构
[1] Korea Atom Energy Res Inst, Sodium Cooled Fast Reactor Design Div, 989-111 Daedeok Daero, Daejeon 305353, South Korea
基金
新加坡国家研究基金会;
关键词
Prototype Gen-IV sodium-cooled fast; reactor (PGSFR); Reactor vault cooling system (RVCS); MARS-LMR; Unprotected event; Reactivity feedback; Severe accident;
D O I
10.1016/j.anucene.2018.02.026
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
KAERI has developed a prototype Gen-IV sodium cooled fast reactor (PGSFR), which is a pool type and metallic fueled fast reactor in Korea. Recently, a reactor vault cooling system (RVCS) was designed as a mitigation feature for severe accidents in the PGSFR. The RVCS which is located between the concrete and containment vessel is a passive cooling system which utilize an air natural circulation. The major goal of the RVCS is to keep the intactness of structures such as containment vessel and reactor vessel and to confine the radioactive materials inside of the vessel. The system has an influence on the reactor vessel temperature and the reactor vessel is an important structure in a reactivity feedback during a transient, since a control rod position is changed by the reactor vessel expansion. In this study, a performance test for the designed RVCS was conducted using an individual RVCS model. In order to check the effect of the RVCS performance under accident conditions, unprotected loss of heat sink (ULOHS) and total heat removal system failure (THRSF) accidents were analyzed with and without RVCS. The RVCS has a favorable effect on the reactivity feedback during the ULOHS because the RV expansion is reduced by enhanced cooling through the RVCS and the current RVCS design has enough capacity for mitigation of a severe accident condition. In addition, in terms of internal structure integrity, the damper opening time effect is also evaluated during the THRSF. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 40 条
  • [1] Analyses of UTOP events for the design of control rod stop system in PGSFR using MARS-LMR
    Choi, Chiwoong
    Ha, Kwiseok
    Jeong, Hae-Yong
    ANNALS OF NUCLEAR ENERGY, 2016, 96 : 422 - 431
  • [2] Numerical study of in-vessel retention under the gallium-water external reactor vessel cooling system using MARS-LMR
    Kang, Sarah
    Park, Seong Dae
    Kim, In Guk
    Bang, In Cheol
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2016, 53 (03) : 345 - 352
  • [3] Thermal-hydraulic tests on passive containment cooling system of advanced PWR
    Tan, Shu-Shi
    Leng, Gui-Jun
    Cheng, Xu
    Ni, Yong-Jun
    Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (SUPPL.): : 30 - 33
  • [4] Thermal-hydraulic Analysis of Passive Containment Cooling System of HPR1000
    Qiu J.
    Wu J.
    Tian W.
    Wang Z.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (01): : 72 - 80
  • [5] Thermal-hydraulic behavior simulations of the reactor cavity cooling system (RCCS) experimental facility using Flownex
    Sena, Marcos S.
    Hassan, Yassin A.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3320 - 3325
  • [6] Investigation on thermal-hydraulic characteristics of the spent fuel pool with a complete passive cooling system
    Han, Fei
    Kuang, Yiwu
    Ye, Cheng
    Wang, Wen
    ANNALS OF NUCLEAR ENERGY, 2022, 177
  • [7] Thermal-hydraulic analyses of the High-Temperature engineering Test Reactor for loss of forced cooling at 30% reactor power
    Takamatsu, Kuniyoshi
    ANNALS OF NUCLEAR ENERGY, 2017, 106 : 71 - 83
  • [8] Modeling the thermal-hydraulic behavior of the reactor cavity cooling system using RELAP5-3D
    Vaghetto, Rodolfo
    Hassan, Yassin A.
    ANNALS OF NUCLEAR ENERGY, 2014, 73 : 75 - 83
  • [9] Review on Thermal-hydraulic Characteristic Research in Passive Cooling Water Tank of Large Advanced Pressurized Water Reactor
    Lu D.
    Zhang Y.
    Li X.
    Zhou S.
    Cao Q.
    Sui D.
    Wang H.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (10): : 1930 - 1940
  • [10] Thermal-hydraulic evaluation of passive containment cooling system of improved APR plus during LOCAs
    Jeon, Byong Guk
    No, Hee Cheon
    NUCLEAR ENGINEERING AND DESIGN, 2014, 278 : 190 - 198