Recovery of low volumes of wear debris from rat stifle joint tissues using a novel particle isolation method

被引:8
|
作者
Patel, J. [1 ]
Lal, S. [1 ]
Nuss, K. [2 ]
Wilshaw, S. P. [4 ]
von Rechenberg, B. [2 ]
Hall, R. M. [3 ]
Tipper, J. L. [1 ,3 ]
机构
[1] Univ Leeds, Fac Biol Sci, Leeds, W Yorkshire, England
[2] Univ Zurich, Musculoskeletal Res Unit, Zurich, Switzerland
[3] Univ Leeds, Sch Mech Engn, Leeds, W Yorkshire, England
[4] Univ Bradford, Sch Pharm & Med Sci, Bradford, W Yorkshire, England
关键词
Silicon nitride; Cobalt chromium; Titanium; Particle isolation; Wear; Total joint replacement; METAL-ON-METAL; HIP PROSTHESES; PERIPROSTHETIC TISSUES; QUANTITATIVE-ANALYSIS; BIOLOGICAL RESPONSE; COBALT-CHROMIUM; POLYETHYLENE; UHMWPE; SHAPE; SIZE;
D O I
10.1016/j.actbio.2018.02.030
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Less than optimal particle isolation techniques have impeded analysis of orthopaedic wear debris in vivo. The purpose of this research was to develop and test an improved method for particle isolation from tissue. A volume of 0.018 mm(3) of clinically relevant CoCrMo, Ti-6AI-4V or Si3N4 particles was injected into rat stifle joints for seven days of in vivo exposure. Following sacrifice, particles were located within tissues using histology. The particles were recovered by enzymatic digestion of periarticular tissue with papain and proteinase K, followed by ultracentrifugation using a sodium polytungstate density gradient. Particles were recovered from all samples, observed using SEM and the particle composition was verified using EDX, which demonstrated that all isolated particles were free from contamination. Particle size, aspect ratio and circularity were measured using image analysis software. There were no significant changes to the measured parameters of CoCrMo or Si3N4 particles before and after the recovery process (KS tests, p > 0.05). Titanium particles were too few before and after isolation to analyse statistically, though size and morphologies were similar. Overall the method demonstrated a significant improvement to current particle isolation methods from tissue in terms of sensitivity and efficacy at removal of protein, and has the potential to be used for the isolation of ultra-low wearing total joint replacement materials from periprosthetic tissues. (C) 2018 Acta Materialia Inc. Published by Elsevier Ltd.
引用
收藏
页码:339 / 350
页数:12
相关论文
共 4 条
  • [1] A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates
    Lal, S.
    Hall, R. M.
    Tipper, J. L.
    [J]. ACTA BIOMATERIALIA, 2016, 42 : 420 - 428
  • [2] Isolation, characterization and quantification of polyethylene wear debris from periprosthetic tissues around total joint replacements
    Slouf, Miroslav
    Eklova, Simona
    Kumstatova, Jitka
    Berger, Stephane
    Synkova, Hana
    Sosna, Antonin
    Pokorny, David
    Spundova, Marcela
    Entlicher, Gustav
    [J]. WEAR, 2007, 262 (9-10) : 1171 - 1181
  • [3] METHOD FOR QUANTITATIVE RECOVERY OF POLYETHYLENE WEAR DEBRIS FROM SIMULATED SERVICE OF TOTAL JOINT PROSTHESES
    ROSE, RM
    SCHNEIDER, H
    RIES, M
    PAUL, I
    CRUGNOLA, A
    SIMON, SR
    RADIN, EL
    [J]. WEAR, 1978, 51 (01) : 77 - 84
  • [4] RECOVERY OF PARTICLES FROM THE PLEURAL CAVITY USING AGAROSE CASTS - A NOVEL METHOD FOR THE DETERMINATION OF FIBER DOSE TO THE RAT PLEURA
    BERMUDEZ, E
    [J]. INHALATION TOXICOLOGY, 1994, 6 (02) : 115 - 124