USING THE ROBOTIC DEVICE REAPLAN AS A VALID, RELIABLE, AND SENSITIVE TOOL TO QUANTIFY UPPER LIMB IMPAIRMENTS IN STROKE PATIENTS

被引:42
|
作者
Gilliaux, Maxime [1 ]
Lejeune, Thierry M. [1 ,2 ]
Detrembleur, Christine [1 ]
Sapin, Julien [3 ]
Dehez, Bruno [3 ]
Selves, Clara [2 ]
Stoquart, Gaetan [1 ,2 ]
机构
[1] Catholic Univ Louvain, Inst Neurosci, Brussels, Belgium
[2] Clin Univ St Luc, Univ Catholique Louvain, Dept Phys Med & Rehabil, B-1200 Brussels, Belgium
[3] Catholic Univ Louvain, Inst Mech Mat & Civil Engn, B-3000 Louvain, Belgium
关键词
robotics; outcome assessment; biomechanics; stroke; upper extremity; reproducibility of results; reference standards; KINEMATIC ANALYSIS; RELIABILITY; REHABILITATION; PERFORMANCE; DEXTERITY; DISCRETE; THERAPY; PEOPLE; PAIN;
D O I
10.2340/16501977-1245
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To validate a protocol assessing upper limb kinematics using a planar robot among stroke patients. Design: Prospective cohort study. Subjects: Age-matched healthy subjects (n=25) and stroke patients (n=25). Methods: Various kinematic indices (n=44) were obtained from 4 tasks performed by subjects with REAplan, a planar end-effector robotic device. The metrological properties of this protocol were studied. Results: In stroke patients, 43 kinematic indices showed moderate to excellent reliability (intraclass correlation coefficients (ICC) range 0.40-0.95; and minimal detectable changes range 9.9-121.1%). In healthy subjects, 25 kinematic indices showed moderate to excellent reliability (ICC range 0.40-0.91) and 3 indices showed a laterality effect (p<0.05). Many of these indices (27 of 44) were altered in stroke patients in comparison with healthy subjects (p<0.05). The Box and Block test (manual dexterity) and Upper Limb Sub-score of the Fugl-Meyer Assessment (motor control) showed moderate to good correlations with, respectively, 13 and 4 indices (r>0.40). Finally, a principal component analysis allowed the elaboration of a short version of the protocol, reducing the number of indices to 5 (i.e. Amplitude, CVstraightness, Speed Metric, CVjerk metric and CVspeed metric). Conclusion: This study provides a standardized, valid, reliable and sensitive protocol to quantify upper limb impairments in stroke patients, using a planar robot.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 50 条
  • [1] ASSESSMENT OF UPPER LIMB SPASTICITY IN STROKE PATIENTS USING THE ROBOTIC DEVICE REAPLAN
    Dehem, Stephanie
    Gilliaux, Maxime
    Lejeune, Thierry
    Detrembleur, Christine
    Galinski, Daniel
    Sapin, Julien
    Vanderwegen, Martin
    Stoquart, Gaetan
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2017, 49 (07) : 565 - 571
  • [2] A ROBOTIC DEVICE AS A SENSITIVE QUANTITATIVE TOOL TO ASSESS UPPER LIMB IMPAIRMENTS IN STROKE PATIENTS: A PRELIMINARY PROSPECTIVE COHORT STUDY
    Gilliaux, Maxime
    Lejeune, Thierry
    Detrembleur, Christine
    Sapin, Julien
    Dehez, Bruno
    Stoquart, Gaetan
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2012, 44 (03) : 210 - 217
  • [3] System identification: a feasible, reliable and valid way to quantify upper limb motor impairments
    van de Ruit, Mark
    van der Velden, Levinia L.
    Onneweer, Bram
    Benner, Joyce L.
    Haarman, Claudia J. W.
    Ribbers, Gerard M.
    Selles, Ruud W.
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2023, 20 (01)
  • [4] System identification: a feasible, reliable and valid way to quantify upper limb motor impairments
    Mark van de Ruit
    Levinia L. van der Velden
    Bram Onneweer
    Joyce L. Benner
    Claudia J. W. Haarman
    Gerard M. Ribbers
    Ruud W. Selles
    [J]. Journal of NeuroEngineering and Rehabilitation, 20
  • [5] Effects of robotic therapy on upper limb motor impairments in chronic stroke
    Fasoli, SE
    Krebs, HI
    Stein, J
    Hughes, R
    McCarthy-Jacobson, A
    Frontera, W
    Hogan, N
    [J]. STROKE, 2002, 33 (01) : 350 - 351
  • [6] Upper limb coordination impairments in patients after stroke
    Hasanbarani, Fariba
    Feldman, Anatol G.
    Levin, Mindy F.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2019, 14 (3_SUPPL) : 29 - 29
  • [7] A passive robotic device for VR-augmented upper limb rehabilitation in stroke patients
    Steinisch, M.
    Tana, M. G.
    Comani, S.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 841 - 844
  • [8] A valid and reliable tool to quantify stool output in tube-fed patients
    Guenter, PA
    Sweed, MR
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1998, 22 (03) : 147 - 151
  • [9] Upper limb and grasp rehabilitation and evaluation of stroke patients using HenRiE device
    Podobnik, Janez
    Mihelj, Matjaz
    Munih, Marko
    [J]. 2009 VIRTUAL REHABILITATION INTERNATIONAL CONFERENCE, 2009, : 173 - 178
  • [10] EFFECT OF ROBOTIC THERAPY ON THE PARETIC UPPER LIMB OF STROKE PATIENTS
    Neves, Gabrielle Fernandes
    Aleixo, Diane Cristina
    Mendes, Izabela Lopes
    Lima, Mario Oliveira
    Tatsukawa de Freitas, Sergio Takeshi
    Florencio das Neves, Marcele
    [J]. REVISTA UNIVAP, 2020, 26 (50) : 64 - 77