Comparing Visual Acuity, Low Contrast Acuity and Refractive Error After Implantation of a Low Cylinder Power Toric Intraocular Lens or a Non-Toric Intraocular Lens

被引:4
|
作者
Gundersen, Kjell Gunnar [1 ]
Potvin, Richard [2 ]
机构
[1] iFocus Oyeklinikk AS, Sorhauggata 111, N-5527 Haugesund, Norway
[2] Sci Vis, Bend, OR USA
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
toric IOL; low cylinder; low contrast acuity; astigmatism correction; CORNEAL ASTIGMATISM; KERATOTOMY;
D O I
10.2147/OPTH.S281178
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare uncorrected and best-corrected visual acuity, low contrast acuity, residual refraction and ocular biometry after low cylinder power toric intraocular lens (IOL) or non-toric IOL implantation. Patients and Methods: This was a non-interventional comparative study of visual outcomes after uncomplicated cataract or refractive lens exchange surgery with either a low cylinder (Low_Cyl) or non-toric (Non_Toric) IOL of similar design implanted (AcrySof((R)) T2 IQ Toric IOL and AcrySof((R)) IQ IOL). Subjects in both groups had to have been eligible for the low cylinder IOL based on biometry. They had to have uncorrected distance visual acuity (UDVA) of 20/32 (0.2 logMAR) or better at the time of their single diagnostic study visit. Clinical evaluation included the manifest refraction, visual acuity (VA), low contrast VA and ocular biometry. Results: A total of 94 eyes were enrolled, 51 Low_Cyl and 43 Non_Toric. The mean manifest refractive cylinder was statistically significantly lower (similar to 0.25 D) in the Low_Toric group (p < 0.01) and significantly more eyes had 0.25 D or less of refractive cylinder in that group (p = 0.03). The orientation of the preoperative anterior corneal astigmatism was a significant cofactor, with the difference between groups more evident when astigmatism was against the rule. Uncorrected high contrast visual acuity was statistically significantly better in the Low_Toric group (p = 0.02) as was the percentage of eyes with 20/20 visual acuity (p = 0.05). Uncorrected low contrast visual acuity was not statistically significantly different in mesopic or photopic conditions. Conclusion: The low cylinder power toric IOL provided better uncorrected visual acuity and lower residual refractive cylinder than a similar non-toric IOL after cataract surgery.
引用
收藏
页码:3661 / 3666
页数:6
相关论文
共 50 条
  • [1] Comparing Visual Acuity, Low Contrast Acuity and Contrast Sensitivity After Trifocal Toric and Extended Depth of Focus Toric Intraocular Lens Implantation
    Gundersen, Kjell G.
    Potvin, Rick
    [J]. CLINICAL OPHTHALMOLOGY, 2020, 14 : 1071 - 1078
  • [2] Comparison of Refractive Stability After Non-toric Versus Toric Intraocular Lens Implantation During Cataract Surgery
    Savini, Giacomo
    Carbonelli, Michele
    Ducoli, Pietro
    Hoffer, Kenneth J.
    Barboni, Piero
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) : 918 - 919
  • [3] Comparison of Refractive Stability After Non-toric Versus Toric Intraocular Lens Implantation During Cataract Surgery
    Jeon, Jei Hun
    Tyler, Rim Hyung Taek
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-Im
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (03) : 658 - 665
  • [4] Visual acuity and refraction with a diffractive multifocal toric intraocular lens
    Bellucci, Roberto
    Bauer, Noel J. C.
    Daya, Sheraz M.
    Visser, Nienke
    Santin, Giorgio
    Cargnoni, Miriam
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1507 - 1518
  • [5] Comparison of Refractive Stability After Non-toric Versus Toric Intraocular Lens Implantation During Cataract Surgery REPLY
    Jeon, Jei Hun
    Rim, Hyung Taek Tyler
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-Im
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) : 919 - 919
  • [6] Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens
    Shimoda, Talita
    Shimoda, Gilberto
    Hida, Wilson Takashi
    Nakano, Celso Takashi
    Motta, Antonio Francisco
    Guimaraees, Aline Silva
    Tzelikis, Patrick Frensel M.
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (02) : 71 - 75
  • [7] VISUAL ACUITY OUTCOME ANALYSIS AND SPECTACLE INDEPENDENCE AFTER TORIC MULTIFOCAL INTRAOCULAR LENS IMPLANTATION IN CATARACT PATIENTS
    Balagopal, Ashok
    Rajasekaran, Ramesh
    Meenakumari
    Ramesh, Prasanna Venkatesh
    Mohan, Kalai
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (50): : 5358 - 5362
  • [8] Prediction of refractive outcomes with toric intraocular lens implantation
    Abulafia, Adi
    Barrett, Graham D.
    Kleinmann, Guy
    Ofir, Shay
    Levy, Adi
    Marcovich, Arie L.
    Michaeli, Adi
    Koch, Douglas D.
    Wang, Li
    Assia, Ehud I.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05): : 936 - 944
  • [9] High and Low Contrast Visual Acuity After Artiflex Phakic Intraocular Lens Implantation for the Correction of Myopia
    van Philips, Lucien A. M.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) : 423 - 429
  • [10] Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens
    Gundersen, Kjell Gunnar
    Potvin, Rick
    [J]. CLINICAL OPHTHALMOLOGY, 2016, 10 : 455 - 461