This paper presents the results of an investigation into the effect of oscillatory flow in a membrane-based affinity contactor. This device was designed to accommodate a tubular affinity membrane, and the flow direction of working fluid was tangential to the surface of the membrane. Cibacron Blue F3G-A was utilized as the capturing ligand and bovine serum albumin as the target molecule. The dye molecules were immobilized covalently via spacer molecules (polyethylenimine) onto the pores of a microfiltration membrane with a pore size rating of 0.45 mu m. Bovine serum albumin was pumped through the annular space between the concentric screw-threaded insert and the tubular membrane in oscillatory flow with a mean flow component. The effects of pulsation frequency and stroke length were investigated. It was found that, as a result of the pulsatile flow, the protein recovery was increased by a factor of 2. To make the interpretation of the results easier, various dimensionless groups were defined specifically for this system and the experimental data were reported in terms of these groups.
引用
收藏
页码:113 / 116
页数:4
相关论文
共 50 条
  • [1] OSCILLATORY CROSS-FLOW ELECTROPHORESIS
    CHANDHOK, AK
    LEIGHTON, DT
    [J]. AICHE JOURNAL, 1991, 37 (10) : 1537 - 1549
  • [2] Effect of morphology of polymeric membrane on the performance of cross-flow microfiltration
    Hwang, KJ
    Lin, TT
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2002, 199 (1-2) : 41 - 52
  • [3] Effect of cross-flow velocity on membrane filtration performance in relation to membrane properties
    Koo, Chai Hoon
    Mohammad, Abdul Wahab
    Suja', Fatihah
    [J]. DESALINATION AND WATER TREATMENT, 2015, 55 (03) : 678 - 692
  • [4] CROSS-FLOW VIBRATIONS OF CYLINDER IN IRREGULAR OSCILLATORY FLOW
    KOZAKIEWICZ, A
    SUMER, BM
    FREDSOE, J
    [J]. JOURNAL OF WATERWAY PORT COASTAL AND OCEAN ENGINEERING-ASCE, 1994, 120 (06): : 515 - 534
  • [5] Intensification of hollow fiber membrane cross-flow filtration by the combination of helical baffle and oscillatory flow
    Horie, Takafumi
    Shiota, Saori
    Akagi, Takaaki
    Ohmura, Naoto
    Wang, Steven
    Eze, Valentine
    Harvey, Adam
    Hirata, Yushi
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2018, 554 : 134 - 139
  • [6] Cross-flow vibrations of cylinder in irregular oscillatory flow - Discussion
    Chakrabarti, SK
    [J]. JOURNAL OF WATERWAY PORT COASTAL AND OCEAN ENGINEERING-ASCE, 1996, 122 (03): : 155 - 156
  • [7] Effect of a hydrodynamic cleaning of a cross-flow membrane system with a novel automated approach
    Shon, H. K.
    Smith, P. J.
    Vigneswaran, S.
    Ngo, H. H.
    [J]. DESALINATION, 2007, 202 (1-3) : 351 - 360
  • [8] EFFECT OF VISCOSITY ON MEMBRANE FLUXES IN CROSS-FLOW ULTRAFILTRATION
    ILIAS, S
    SCHIMMEL, KA
    ASSEY, GEJM
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 1995, 30 (7-9) : 1669 - 1687
  • [9] Establishment of CFD model for rotating cross-flow membrane separation device
    Chen, Zhihao
    Li, Liuhuan
    Cheng, Dazhou
    [J]. 2018 INTERNATIONAL CONFERENCE ON CONSTRUCTION, AVIATION AND ENVIRONMENTAL ENGINEERING, 2019, 233
  • [10] Internal flow and performance of cross-flow fan
    Fukutomi, Junichiro
    Nakase, Yoshiyuki
    Izawa, Shoichiro
    Tamaki, Masashi
    [J]. Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1995, 61 (590): : 3699 - 3705