Radiation Dose Reduction in Pediatric Cardiac Computed Tomography: Experience from a Tertiary Medical Center

被引:67
|
作者
Ghoshhajra, Brian B. [1 ]
Lee, Ashley M. [1 ]
Engel, Leif-Christopher [1 ]
Celeng, Csilla [1 ]
Kalra, Mannudeep K. [1 ]
Brady, Thomas J. [1 ]
Hoffmann, Udo [1 ]
Westra, Sjirk J. [1 ]
Abbara, Suhny [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Cardiac MR PET CT Program, Boston, MA 02114 USA
关键词
Cardiac computed tomography angiography; Pediatrics; Children; Low dose; Radiation; CARDIOVASCULAR MAGNETIC-RESONANCE; CT CORONARY-ANGIOGRAPHY; DUAL-SOURCE CT; IMAGE QUALITY; HIGH-PITCH; TEMPORAL RESOLUTION; SHOOT MODE; PROTECTION; ACCURACY; CHILDREN;
D O I
10.1007/s00246-013-0758-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac CT angiography (cCTA) has become an established method for the assessment of congenital heart disease. However, the potential harmful effects of ionizing radiation must be considered, particularly in younger, more radiosensitive patients. In this study, we sought to assess the temporal change in radiation doses from pediatric cCTA during an 8-year period at a tertiary medical center. This retrospective study included all patients a parts per thousand currency sign18 years old who were referred to electrocardiography (ECG)-gated cCTA for the assessment of congenital heart disease or inflammatory disease (Kawasaki disease) from November 2004 to September 2012. During the study period, 95 patients were scanned using 3 different scanner models-64-slice multidetector CT (64-MDCT) and first- (64-DSCT) and second-generation (128-DSCT) dual-source CT-and 3 scan protocols-retrospective ECG-gated helical scanning (RG), prospective ECG-triggered axial scanning (PT), or prospective ECG-triggered high-pitch helical scanning (HPH). Effective dose (ED) was calculated with the dose length product method with a conversion factor (k) adjusted for age. ED was then compared among scan protocols. Image quality was extracted from clinical cCTA reports when available. Overall, 94 % of scans were diagnostic (80 % for 64-slice MDCT, 93 % for 64-slice DSCT, and 97 % for 128-slice DSCT).With 128-DSCT, median ED (1.0 [range 0.6-2.0] mSv) decreased by 85.8 % and 66.8 % compared with 64-MDCT (6.8 [range 2.9-13.6] mSv) and 64-DSCT (2.9 [range 0.9-4.1] mSv), respectively. With HPH, median ED (0.9 [range 0.6-1.8] mSv) decreased by 59.4 % and 85.4 % compared with PT (2.2 [range 0.9-3.4] mSv) and RG (6.1 [range 2.5-10.6] mSv). cCTA can now be obtained at very low radiation doses in pediatric patients using the latest dual-source CT technology in combination with prospective ECG-triggered HPH acquisition.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [1] Radiation Dose Reduction in Pediatric Cardiac Computed Tomography: Experience from a Tertiary Medical Center
    Brian B. Ghoshhajra
    Ashley M. Lee
    Leif-Christopher Engel
    Csilla Celeng
    Mannudeep K. Kalra
    Thomas J. Brady
    Udo Hoffmann
    Sjirk J. Westra
    Suhny Abbara
    [J]. Pediatric Cardiology, 2014, 35 : 171 - 179
  • [2] RADIATION DOSE REDUCTION IN PEDIATRIC CARDIAC COMPUTED TOMOGRAPHY: EXPERIENCE FROM A TERTIARY MEDICAL CENTER
    Engel, Leif-Christopher
    Sidhu, Manavjot
    Lee, Ashley
    Abbara, Suhny
    Kalra, Manudeep
    Brady, Thomas J.
    Hoffmann, Udo
    Ghoshhajra, Brian
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1356 - E1356
  • [3] Evolution of Coronary Computed Tomography Radiation Dose Reduction at a Tertiary Referral Center
    Ghoshhajra, Brian Burns
    Engel, Leif-Christopher
    Major, Gyoengyi Petra
    Goehler, Alexander
    Techasith, Tust
    Verdini, Daniel
    Do, Synho
    Liu, Bob
    Li, Xinhua
    Sala, Michiel
    Kim, Mi Sung
    Blankstein, Ron
    Prakash, Priyanka
    Sidhu, Manavjot S.
    Corsini, Erin
    Banerji, Dahlia
    Wu, David
    Abbara, Suhny
    Quynh Truong
    Brady, Thomas J.
    Hoffmann, Udo
    Kalra, Manudeep
    [J]. AMERICAN JOURNAL OF MEDICINE, 2012, 125 (08): : 764 - 772
  • [4] Radiation Dose Reduction Using 320-Slice Cardiac Computed Tomography: Experience from a Single Center in Singapore
    Lim, Choon Pin
    Tan, Swee Yaw
    Chua, Terrance
    Cheah, Foong Koon
    [J]. CIRCULATION, 2010, 122 (02) : E205 - E205
  • [5] Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging
    Albert, Gregory W.
    Glasier, Charles M.
    [J]. NEUROSURGERY, 2015, 77 (02) : 228 - 232
  • [6] PEDIATRIC DOSE REDUCTION IN COMPUTED TOMOGRAPHY
    Frush, Donald P.
    [J]. HEALTH PHYSICS, 2008, 95 (05): : 518 - 527
  • [7] Radiation Dose From Cardiac Computed Tomography Before and After Implementation of Radiation Dose-Reduction Techniques
    Raff, Gilbert L.
    Chinnaiyan, Kavitha M.
    Share, David A.
    Goraya, Tauqir Y.
    Kazerooni, Ella A.
    Moscucci, Mauro
    Gentry, Ralph E.
    Abidov, Aiden
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (22): : 2340 - 2348
  • [8] Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging Comment
    Flannery, Ann Marie
    Selden, Nathan R.
    [J]. NEUROSURGERY, 2015, 77 (02) : 232 - 232
  • [9] Radiation Dose-Reduction Program for Cardiac Computed Tomography Angiography
    Torres, Felipe S.
    Crean, Andrew M.
    Paul, Narinder
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 302 (16): : 1753 - 1753
  • [10] Pediatric Residents' and Medical Interns' Awareness about Pediatric Ionizing Radiation Dose from Computed Tomography and Its Associated Risks in Tertiary Hospital in Ethiopia
    Teferi, Seife
    Zewdeneh, Daniel
    Bekele, Solomon
    [J]. ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2018, 28 (04) : 383 - 392