ELLIPTA Dry Powder Versus Metered-Dose Inhalers in an Optimized Clinical Trial Setting

被引:4
|
作者
Kerwin, Edward M. [1 ]
Preece, Andrew [2 ]
Brintziki, Dimitra [3 ]
Collison, Kathryn A. [4 ]
Sharma, Raj [5 ]
机构
[1] Clin Res Inst Southern Oregon, 3680 Crater Lake Ave, Medford, OR 97504 USA
[2] GlaxoSmithKline Plc, Resp Therapy Area Unit, Stockley Pk West, Uxbridge, Middx, England
[3] GlaxoSmithKline Plc, Resp Clin Stat, Stockley Pk West, Uxbridge, Middx, England
[4] GlaxoSmithKline Plc, Durham, NC USA
[5] GlaxoSmithKline Plc, Resp Med Franchise, Brentford, Middx, England
来源
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE | 2019年 / 7卷 / 06期
关键词
ELLIPTA; Dry powder inhaler; Metered-dose inhaler; Inhaler technique; Inhaler errors; Optimized technique; Inhaler training; Clinical trial; OBSTRUCTIVE PULMONARY-DISEASE; ASTHMA; KNOWLEDGE; DEVICES; PHYSICIANS;
D O I
10.1016/j.jaip.2019.02.023
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
BACKGROUND: Reduced error rates have been demonstrated with the ELLIPTA inhaler versus other commonly used devices. OBJECTIVE: This phase IV, randomized, crossover study evaluated correct use of ELLIPTA compared with 2 commonly prescribed metered-dose inhalers (MDIs) in adults with asthma and optimized inhaler technique. METHODS: The study comprised 2 crossover substudies (ELLIPTA vs MDI-1 and ELLIPTA vs MDI-2). Inhaler use was assessed at the start of each period, following instruction from a health care professional, and after 28 days of use without instruction. Data for each inhaler were pooled within substudies, irrespective of treatment sequence; study objectives were addressed in each substudy. The primary end point, percentage of participants making 0 errors after 28 days of use, was analyzed separately for each substudy using a Mainland-Gart test for each ELLIPTA versus MDI comparison. RESULTS: Correct use rates after 28 days were higher with ELLIPTA than with MDI-1 and MDI-2 (ELLIPTA vs MDI-1, 96% vs 84%; ELLIPTA vs MDI-2, 98% vs 91%). Among discordant cases, statistically significantly more participants correctly used ELLIPTA but made 1 or more overall error with MDIs than did those who correctly used the MDIs but made 1 or more overall error using ELLIPTA (87% vs 13% in both substudies; P < .001 and P = .007 for ELLIPTA vs MDI-1 and ELLIPTA vs MDI-2, respectively). More participants made multiple device errors with MDIs than with ELLIPTA. CONCLUSIONS: Inhaler technique can be optimized in trial settings. In such settings, ELLIPTA is associated with higher rates of correct use and lower error rates than are MDIs. (C) 2019 The Authors. Published by Elsevier Inc. on behalf of the American Academy of Allergy, Asthma & Immunology.
引用
收藏
页码:1843 / 1849
页数:7
相关论文
共 50 条
  • [1] Dry powder inhalers are environmentally preferable to metered-dose inhalers
    Wintemute, Kimberly
    Miller, Fiona
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2020, 192 (29) : E846 - E846
  • [2] METERED-DOSE INHALERS AND NEBULIZERS IN THE ACUTE SETTING
    KISCH, GL
    PALOUCEK, FP
    ANNALS OF PHARMACOTHERAPY, 1992, 26 (01) : 92 - 95
  • [3] Do patients prefer dry powder inhalers or metered-dose inhalers? A retrospective, combined analysis
    Morice, AH
    Adler, LM
    Ellis, S
    Hewitt, A
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 2002, 63 (08): : 496 - 506
  • [4] POWER REQUIREMENT OF PRESSURIZED METERED-DOSE AND DRY POWDER INHALERS (pMDIs AND DPIs)
    Haidl, Peter
    Pohlmann, Gerhard
    Cloes, Rolf-Michael
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (03) : A22 - A22
  • [5] METERED-DOSE INHALERS
    MOORE, A
    BRITISH MEDICAL JOURNAL, 1993, 307 (6917): : 1498 - 1498
  • [6] Handling of inhaler devices in actual pulmonary practice: Metered-dose inhaler versus dry powder inhalers
    Khassawneh, Basheer Y.
    Al-Ali, Musa K.
    Alzoubi, Karem H.
    Batarseh, Morad Z.
    Al-Safi, Saafan A.
    Sharara, Abdelmonem M.
    Alnasr, Hatem M.
    RESPIRATORY CARE, 2008, 53 (03) : 324 - 328
  • [7] Bronchoprotection with formoterol via dry powder and metered-dose inhalers in patients with asthma
    Lipworth, BJ
    Sims, EJ
    Das, SK
    Morice, AH
    O'Connor, BJ
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2005, 95 (03) : 283 - 290
  • [8] Teaching time for metered-dose inhalers in the emergency setting
    Numata, Y
    Bourbeau, J
    Ernst, P
    Duquette, G
    Schwartzman, K
    CHEST, 2002, 122 (02) : 498 - 504
  • [9] Equivalence testing and equivalence limits of metered-dose inhalers and dry powder inhalers measured by in vitro impaction
    Weda, M
    Geuns, ERM
    Vermeer, RCR
    Buiten, NRA
    Hendriks-de Jong, K
    Bult, A
    Zanen, P
    Barends, DM
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2000, 49 (03) : 295 - 302
  • [10] Clinical efficacy of metered-dose inhalers versus nebulisers: A systematic review
    Brocklebank, D
    Ram, F
    Muers, M
    Wright, J
    THORAX, 2000, 55 : A63 - A63