Enhanced performance and microbial community analysis of bioelectrochemical system integrated with bio-contact oxidation reactor for treatment of wastewater containing azo dye

被引:56
|
作者
Wang, Youzhao [1 ]
Pan, Yuan [1 ]
Zhu, Tong [1 ]
Wang, Aijie [2 ]
Lu, Yalun [1 ]
Lv, Liting [1 ]
Zhang, Kuo [1 ]
Li, Zijun [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang 110004, Liaoning, Peoples R China
[2] Chinese Acad Sci, Ecoenvironm Sci Res Ctr, Key Lab Environm Biotechnol, Beijing 100085, Peoples R China
基金
中国国家自然科学基金;
关键词
Bioelectrochemical systems; Bio-contact oxidation; Azo dye removal; Response surface methodology; Microbial community structure; RESPONSE-SURFACE METHODOLOGY; FUEL-CELLS; GEOBACTER-SULFURREDUCENS; ELECTROLYSIS CELLS; ENERGY RECOVERY; PALM OIL; DECOLORIZATION; BIODEGRADATION; DEGRADATION; EFFLUENT;
D O I
10.1016/j.scitotenv.2018.03.346
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Feasibility and superiority of the bioelectrochemical system integrated with biocontact oxidation (BES-BCO) for degradation and/or mineralization of azo dyes have been confirmed. In this study, the effects of hydraulic retention time (HRT), applied voltage, and dissolved oxygen (DO) concentration at the bioanode on the performance of BES-BCO and traditional BES were investigated. Using the response surface methodology, the optimum values of HRT, applied voltage, and DO concentration at the bioanode of BES-BCO were investigated to obtain the maximum decolouration and COD removal efficiency and minimum specific energy consumption (SEC). The microbial community structure in BES-BCO was studied for analyzing the change following the introduction of oxygen. The optimised solution was an applied voltage of 0.59 V, HRT of 12 h, and DO concentration of 0.96 mg/L at the bioanode. Under such conditions, the DE, COD removal efficiency, and SEC values were 94.62 +/- 0.63%, 89.12 +/- 0.32%, and 687.57 +/- 3.86 J/g, respectively. In addition, after changing from BES to BES-BCO, the bacterial community structure of the bioanode underwent significant changes. Several aerobic aniline-degrading bacteria and anode-respiration bacteria (ARB) were found to dominate the community of the anode biofilm. The results showed that the removal of azo dye degradation by-products was closely correlated with the o-bioanode and the BCO bacterial community structure. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:616 / 627
页数:12
相关论文
共 50 条
  • [1] Removal of azo dye in an up-flow membrane-less bioelectrochemical system integrated with bio-contact oxidation reactor
    Pan, Yuan
    Wang, Youzhao
    Zhou, Aijuan
    Wang, Aijie
    Wu, Zongting
    Lv, Liting
    Li, Xianjin
    Zhang, Kuo
    Zhu, Tong
    [J]. CHEMICAL ENGINEERING JOURNAL, 2017, 326 : 454 - 461
  • [2] Aerobic treatment of oilfield wastewater with a bio-contact oxidation reactor
    Lu, Mang
    Wei, Xiaofang
    Su, Youming
    [J]. DESALINATION AND WATER TREATMENT, 2011, 27 (1-3) : 334 - 340
  • [3] Enhanced azo dye decolorization and microbial community analysis in a stacked bioelectrochemical system
    Kong, Fanying
    Ren, Hong-Yu
    Pavlostathis, Spyros G.
    Wang, Aijie
    Nan, Jun
    Ren, Nan-Qi
    [J]. CHEMICAL ENGINEERING JOURNAL, 2018, 354 : 351 - 362
  • [4] Enhanced Removal of Azo Dye by a Bioelectrochemical System Integrated with a Membrane Biofilm Reactor
    Pan, Yuan
    Zhu, Tong
    He, Zhen
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (48) : 16433 - 16441
  • [5] Performance and microbial community analysis of a bio-contact oxidation reactor during the treatment of low-COD and high-salinity oilfield produced water
    Zhou, Hanghai
    Chen, Chunlei
    Zhou, Shaoxiong
    Bu, Kuiyong
    Li, Pingyuan
    Lin, Xiaoyun
    Jiang, Lijia
    Zhang, Chunfang
    [J]. BIORESOURCE TECHNOLOGY, 2021, 335
  • [6] Evaluation of decentralized treatment of sewage employing bio-contact oxidation reactor integrated with filter bed
    Li, Zhenhua
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2013, 91 (04) : 295 - 303
  • [7] Azo dye removal in a membrane-free up-flow biocatalyzed electrolysis reactor coupled with an aerobic bio-contact oxidation reactor
    Cui, Dan
    Guo, Yu-Qi
    Cheng, Hao-Yi
    Liang, Bin
    Kong, Fan-Ying
    Lee, Hyung-Sool
    Wang, Ai-Jie
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2012, 239 : 257 - 264
  • [8] Azo dye wastewater treatment in a bioelectrochemical-aerobic integrated system: effect of initial azo dye concentration and aerobic sludge concentration
    Cui, Min-Hua
    Gao, Jian
    Wang, Ai-Jie
    Sangeetha, Thangavel
    [J]. DESALINATION AND WATER TREATMENT, 2019, 165 : 314 - 320
  • [9] Enhanced degradation of azo dye alizarin yellow R in a combined process of iron–carbon microelectrolysis and aerobic bio-contact oxidation
    Bin Liang
    Qian Yao
    Haoyi Cheng
    Shuhong Gao
    Fanying Kong
    Dan Cui
    Yuqi Guo
    Nanqi Ren
    Aijie Wang
    [J]. Environmental Science and Pollution Research, 2012, 19 : 1385 - 1391
  • [10] Analysis of electrode microbial communities in an up-flow bioelectrochemical system treating azo dye wastewater
    Cui, Min-Hua
    Cui, Dan
    Gao, Lei
    Cheng, Hao-Yi
    Wang, Ai-Jie