摘要
In this study, effect of air change rate (air change per hour - ACH) on indoor particle dispersion and deposition in a ventilated room is investigated. A reduced-scale model is designed to conduct experiments. Numerical predictions are performed by using the commercial software ANSYS Fluent 16.0. Four different values of the air change rate (1.73, 2.88, 5.76 and 7.68) and five different values of the particle diameter (0.181, 2.188, 4.42, 8.89 and 17.8 mu m) are considered. Constant particle flow rate and proportional particle flow rate with inlet velocity cases are examined comparatively. Results show that, except from some inconsistencies for the largest particle diameter due to the accumulation and outlet opening location, the contaminant level decreases with increasing air change rate for a constant value of the particle flow rate while an opposite trend is observed for the proportional particle flow rate case.
引用
收藏
页码:177 / 194
页数:18
相关论文
共 50 条
  • [1] The Effect of Sampling Inlet Direction and Distance on Particle Source Measurements for Dispersion Modelling
    Jensen, Alexander Christian Osterskov
    Poikkimaki, Mikko
    Brostrom, Anders
    Dal Maso, Miikka
    Nielsen, Ole John
    Rosenorn, Thomas
    Butcher, Andrew
    Koponen, Ismo Kalevi
    Koivisto, Antti Joonas
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2019, 19 (05) : 1114 - 1125
  • [2] Effects of supply air temperature and inlet locations on particle dispersion in a displacement ventilated room
    Kang, Yanming
    Wang, Youjun
    Zhong, Ke
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 991 - 998
  • [3] Effects of supply air temperature and inlet location on particle dispersion in displacement ventilation rooms
    Kang, Yanming
    Wang, Youjun
    Zhong, Ke
    [J]. PARTICUOLOGY, 2011, 9 (06) : 619 - 625
  • [5] Particle dispersion in a room with under-floor air distribution
    Zhang, Z
    Chen, Q
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2723 - 2728
  • [6] Effect of source location on particle dispersion in displacement ventilation rooms
    Zhong, Ke
    Kang, Yanming
    Wang, Youjun
    [J]. PARTICUOLOGY, 2008, 6 (05) : 362 - 368
  • [7] Effect of source location on particle dispersion in displacement ventilation rooms
    Ke Zhong
    [J]. Particuology, 2008, (05) : 362 - 368
  • [8] Effect of dispersion on particle segregation due to sparged air in a hydrocyclone
    Liu, SJ
    Zhu, ZX
    Masliyah, JH
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (3-4): : 549 - 556
  • [9] EFFECT OF DRYER INLET AIR TEMPERATURE, PHOSPHATE ROCK PARTICLE SIZE, AND SURFACTANTS
    BRIDGER, GL
    KEARNS, JL
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1956, 4 (06) : 526 - 531
  • [10] Particle Concentration Comparison of Radiator and Floor Heating Systems under Zero Air Change Rate Condition
    Mutlu, Mustafa
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (11)