Measurement of lung tumor volumes using three-dimensional computer planning software

被引:73
|
作者
Bowden, P
Fisher, R
Mac Manus, M
Wirth, A
Duchesne, G
Millward, M
McKenzie, A
Andrews, J
Ball, D
机构
[1] Peter MacCallum Canc Inst, Div Radiat Oncol, Melbourne, Vic 8006, Australia
[2] Peter MacCallum Canc Inst, Ctr Stat, Melbourne, Vic 8006, Australia
[3] Peter MacCallum Canc Inst, Div Haematol & Med Oncol, Melbourne, Vic 8006, Australia
[4] Peter MacCallum Canc Inst, Dept Diagnost Imaging, Melbourne, Vic 8006, Australia
关键词
non-small-cell lung cancer; tumor volume; three-dimensional treatment planning;
D O I
10.1016/S0360-3016(02)02783-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To examine the interclinician variation in the definition of gross tumor volume (GTV) in patients undergoing radiotherapy for non-small-cell lung cancer (NSCLC), develop methods to minimize this variation, and test these methods. Methods and Materials: The radiotherapy planning computed tomography (CT) scans of 6 consecutive patients with NSCLC in which the radiologist was able to define and outline the GTV were used. Six oncologists independently contoured the tumors with the radiologist's markings as a guide using a three-dimensional treatment planning system. Separate contours were prepared using only mediastinal window settings and using both mediastinal and lung window settings. The volumes were calculated using the planning system software (series 1). Factors that resulted in interclinician variation were determined, and, after a 3-year interval, 5 of the 6 clinicians redefined the GTVs using a revised protocol aimed at minimizing variation (series 2). Results: For series 1, the interclinician variation in the measurement of volumes ranged from 5%, in the most tightly measured tumor, to 42%, in the most variable, but was, on average, 20%. Statistically significant differences were noted among the clinicians (p = 0.002), that is, some clinicians tended to record relatively small and some relatively large volumes. The reasons for the variation among the oncologists included a tendency to include regions with a low probability of containing tumor, as if the oncologist were contouring a target volume; inclusion of adjacent atelectasis (ignoring the radiologist's outline); and variable treatment of spicules. When the exercise was repeated using the revised protocol (series 2), the degree of interclinician variation was reduced, with a range of 7-22% (average 13%). In series 2, the differences among the clinicians were not statistically significant (p = 0.25). Conclusion: Despite major radiologic input, significant variation occurred in the delineation of the three-dimensional GTVs of NSCLC among oncologists. Standardization of the approach with guidelines resulted in a reduction in this variation. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:566 / 573
页数:8
相关论文
共 50 条
  • [1] Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing
    Oshiro, Yukio
    Ohkohchi, Nobuhiro
    [J]. TISSUE ENGINEERING PART A, 2017, 23 (11-12) : 474 - 480
  • [2] Three dimensional planning target volumes: A model and a software tool
    AustinSeymour, M
    Kalet, I
    McDonald, J
    KromhoutSchiro, S
    Jacky, J
    Hummel, S
    Unger, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1073 - 1080
  • [3] Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study
    Nozaki, Asami
    Imai, Norio
    Funayama, Kazuhisa
    Horigome, Yoji
    Suzuki, Hayato
    Minato, Izumi
    Kobayashi, Koichi
    Kawashima, Hiroyuki
    [J]. MEDICINA-LITHUANIA, 2023, 59 (06):
  • [4] Automatically planning the inspection of three-dimensional objects using stereo computer vision
    Marshall, AD
    Roberts, DR
    [J]. THREE-DIMENSIONAL AND UNCONVENTIONAL IMAGING FOR INDUSTRIAL INSPECTION AND METROLOGY, 1996, 2599 : 94 - 105
  • [5] Serial fetal lung volume measurement using three-dimensional ultrasound
    Bahmaie, A
    Hughes, SW
    Clark, T
    Milner, A
    Saunders, J
    Tilling, K
    Maxwell, DJ
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (02) : 154 - 158
  • [6] Consistency of three-dimensional planning target volumes across physicians and institutions
    Ketting, CH
    AustinSeymour, M
    Kalet, I
    Unger, J
    Hummel, S
    Jacky, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02): : 445 - 453
  • [7] The research of route planning in the measurement of three-dimensional profile
    Li, B
    Tian, S
    Han, T
    Sui, L
    Jiang, Z
    [J]. COMPUTER-AIDED PRODUCTION ENGINEERING, 2001, : 393 - 396
  • [8] Frontal bone and modified zygomatic implants for retention of a nasal prosthesis: Surgical planning using a three-dimensional computer software program
    Walivaara, Dan-Ake
    Isaksson, Sten
    Johansson, Lars-Ake
    [J]. JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2011, 45 (02) : 109 - 112
  • [9] Three-Dimensional Preoperative Planning Software for Hip Resurfacing Arthroplasty
    Alagha, M. Abdulhadi
    Logishetty, Kartik
    O'Hanlon, Ciaran
    Liddle, Alexander D.
    Cobb, Justin
    [J]. BIOENGINEERING-BASEL, 2023, 10 (08):
  • [10] Development and Proof-of-Concept of Three-dimensional Lung Histology Volumes
    Mathew, Lindsay
    Alabousi, Mostafa
    Wheatley, Andrew
    Aladl, Usaf
    Slipetz, Deborah
    Hogg, James C.
    Fenster, Aaron
    Parraga, Grace
    [J]. MEDICAL IMAGING 2012: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2012, 8317