RETRACTED: Diagnostic value of proton MR spectroscopy in peripheral arterial occlusive disease: A prospective evaluation (Retracted Article)

被引:3
|
作者
Stueckle, Christoph A.
Claeys, Luc
Haegele, Kerstin
Zimmermann, Stephan
Mruck, Stefan
Adams, Stefan
Liermann, Dieter
机构
[1] Marien Hosp, Univ Klin, Dept Radiol, Herne, Germany
[2] Univ Hosp Bergmannsheil, Inst Neurol, Bochum, Germany
关键词
H-1 MR spectroscopy; metabolism; MRI; MRS; MR spectroscopy; peripheral arterial occlusive disease; peripheral vascular disease;
D O I
10.2214/AJR.05.0819
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of the present study was to determine the detectability of metabolic alterations in patients with peripheral arterial occlusive disease (PAOD) using proton MR spectroscopy (hydrogen-1 MR spectroscopy). SUBJECTS AND METHODS. Twenty-seven people were included in this study: 10 patients with PAOD and a pain-free walking distance of less than 200 in served as the patient group and 17 young healthy subjects served as a control group. Hydrogen-1 MR spectroscopy was performed on a 1.5-T scanner using an extremity coil and a point-resolved spectroscopy (PRESS) sequence (TR/TE, 1,500/30; 256 repetitions). For the patient group, a voxel was localized in the gastrocnemius muscle of the diseased leg. The data were processed using standard H-1 MR spectroscopy tools. The identification of resonances detected on all MR spectra was made: intramyocellular lipids at 1.2 ppm, extramyocellular lipids at 1.6 ppm, lactate at 4.1 ppm, glucose with two main peaks at 3.4 and 3.8 ppm, choline at 3.2 ppm, and creatine at 3.0 and 3.9 ppm. To avoid operator bias, three spectral intensities were measured after correcting baseline and phase of MR spectra each time. The creatine signal was used as an internal reference; thus, all spectra were scaled relative to creatine. We compared the resultant intensity ratios between the two groups using the Mann-Whitney U test. RESULTS. The lactate-creatine quotient was higher in the patient group, with a ratio of 1.6, than in the control group, with a ratio of 0.6. The glutamate-creatine ratio was higher in the patient group than in the control group (1.3 vs 0.8, respectively). All other ratios were higher in the control group. The best ratio for differentiating between healthy subjects and patients with PAOD was the glucose-lactate ratio. The patient group had a glucose-lactate quotient of 5.4, whereas the control group had a glucose-lactate quotient of 21.5 (p = 0.001). CONCLUSION. Proton MR spectroscopy has the potential to allow identification of patients who have PAOD on the basis of altered muscle metabolism.
引用
收藏
页码:1322 / 1326
页数:5
相关论文
共 50 条
  • [1] RETRACTED: Detection and Prediction of Peripheral Arterial Plaque Using Vessel Wall MR in Patients with Diabetes (Retracted Article)
    Wang, Li
    Deng, Wei
    Liang, Jianke
    Zhuang, Weizhao
    Feng, Huigang
    Zhuang, Gaoming
    Liu, Dexiang
    Chen, Hanwei
    [J]. BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [2] RETRACTED: MRI Manifestations and Diagnostic Value of Chronic Osteomyelitis (Retracted Article)
    Lin, Bingyuan
    Guo, Qiaofeng
    Ren, Haiyong
    Liu, Yiyang
    Huang, Kai
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [3] Prospective evaluation of peripheral arterial occlusive disease by 2D MR subtraction angiography
    Laissy, JP
    Debray, MP
    Menegazzo, D
    Rangheard, AS
    Benamer, H
    Charlier, P
    Schouman-Claeys, E
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1060 - 1065
  • [4] RETRACTED: Effect of Peptidylarginine Deiminase 4 on Endothelial Progenitor Cell Function in Peripheral Arterial Disease (Retracted Article)
    Pan, Jialin
    Liu, Wenqin
    Chen, Ye
    Zhang, Chi
    Lin, Cong
    [J]. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2021, 2021
  • [5] RETRACTED: Diagnostic Value of Inflammatory Markers and Cytokines in Neonatal Sepsis (Retracted Article)
    Wu, Lijie
    Li, Jinku
    Ping, Lili
    Zhang, Xiaoli
    Zhai, Lina
    Li, Yanmin
    Zhang, Ruimin
    [J]. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2022, 2022
  • [6] RETRACTED: Diagnostic Value of Color Doppler Ultrasonography in Subacute Thyroiditis (Retracted Article)
    Chen, Yonggang
    Zhu, Shulan
    Chen, Huabin
    Yao, Liting
    Zhou, Jingmian
    Xu, Yi
    Lin, Biqin
    Chen, Xiaoping
    [J]. SCANNING, 2022, 2022
  • [7] RETRACTED: Diagnostic Value of Specialist Systems in Sports Knee Injuries (Retracted Article)
    Chen, Xi
    Yu, Ao
    Cai, Ning
    Wei, Saite
    Tong, Yongqing
    [J]. SCANNING, 2022, 2022
  • [8] RETRACTED: The Diagnostic Value of Scanning in the Injury of Triceps Crus of Volleyball Players (Retracted Article)
    Zhao, Jinfeng
    Liu, Jianxin
    [J]. SCANNING, 2022, 2022
  • [9] RETRACTED: Diagnostic Value of CT Window Technique for Primary Omentum Infarction (Retracted Article)
    Du, Yue
    Chen, Yan
    Li, Cai-hong
    Zhou, Bi
    Wu, Jin-liang
    Gu, Liang-rui
    Yang, Kai
    [J]. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [10] RETRACTED: EEG Synchronization Evaluation: A New Diagnostic Tool for Predicting the Progression of Alzheimer's disease (Retracted Article)
    Yi, Ran
    Zhan, Xiao-rong
    Tang, Jing
    Zhang, Li-ming
    Liu, Xiao-min
    Dong, Qi
    [J]. CLINICAL EEG AND NEUROSCIENCE, 2015, 46 (02) : 130 - 135