Retrofit with Hybrid Insulation System of a Failed Power Transformer

被引:0
|
作者
Lim, T. [1 ]
Duart, J. C. [2 ]
机构
[1] DuPont Co Inc, Singapore 098633, Singapore
[2] DuPont Co Inc, Geneva, Switzerland
关键词
Aramid insulation; capacity expansion; hybrid insulation system; improved reliability; loss reduction; retrofit transformers; winding temperature rise;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Retrofit of power transformers using high temperature aramid insulation materials in the windings based on the hybrid insulation system has developed over the last two decades. By taking advantage of the higher thermal withstand properties of such insulation materials, a failed unit could be redesigned to increase its average winding rise to 95 degrees C. The windings can then be redesigned to reduce the cooling space but replaced with more active material, thereby optimising the use of the available space within the core window. This approach enhances the transformer retrofit scope and flexibility which includes capacity expansion or loss reduction and improved reliability of the retrofitted transformers.
引用
收藏
页码:1281 / +
页数:2
相关论文
共 50 条
  • [1] Novel Insulation system in power transformer
    Aruna, M.
    Vasudev, N.
    Ravi, K. N.
    Pattanshetti, V. V.
    [J]. 2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [2] DIELECTRIC STRENGTH ASSESSMENT OF POWER TRANSFORMER INSULATION SYSTEM
    Sudha, R.
    Jain, Deepak
    Lahoty, Umang
    Pathak, Gaurav
    Vats, Vishwas
    [J]. FOURTH INTERNATIONAL CONFERENCE ON COMPUTER AND ELECTRICAL ENGINEERING (ICCEE 2011), 2011, : 241 - 245
  • [3] Modeling of electrical stresses in power transformer insulation system
    Adamczyk, Bartlomiej
    Florkowski, Marek
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (5A): : 90 - 93
  • [4] A methodology for the optimized design of power transformer insulation system
    Rodriguez-Ignacio, Hugo
    Lopez-Fernandez, Xose M.
    Alvarez-Marino, Casimiro
    [J]. COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 37 (03) : 1002 - 1010
  • [5] Retrofit of a Resilient Hybrid Power System for a Remote Island
    Chen, Cheng-Liang
    Chen, Hui-Chu
    Lee, Jui-Yuan
    [J]. PRES15: PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2015, 45 : 163 - 168
  • [6] Effect of Power System Harmonic on Degradation process of Transformer Insulation System
    Sumaryadi
    Gumilang, Harry
    Susilo, Achmad
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 261 - +
  • [7] Diagnosis of power transformer insulation
    Gockenbach, E.
    [J]. ICPASM 2005: Proceedings of the 8th International Conference on Properties and Applications of Dielectric Materials, Vols 1 and 2, 2006, : 234 - 237
  • [8] CORONA IN POWER TRANSFORMER INSULATION
    NORRIS, ET
    [J]. ELECTRICAL REVIEW, 1969, 185 (09): : 305 - &
  • [9] Investigation of a Power Transformer's Insulation and Cooling System Functionality
    Doncuk, Jan
    Mentlik, Vaclav
    Velek, Jiri
    Ullman, Ivo
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 401 - 404
  • [10] Degradation Mechanism of Power Transformer's Insulation System in PLN Indonesia
    Gumilang, Harry
    Risal, Fakhrul
    [J]. 2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 317 - 320