Heat transfer and pressure drop of ice slurries in plate heat exchangers

被引:108
|
作者
Bellas, J [1 ]
Chaer, I [1 ]
Tassou, SA [1 ]
机构
[1] Brunel Univ, Dept Mech Engn, Uxbridge UB8 3PH, Middx, England
关键词
ice slurries; plate heat exchangers; pressure drop; heat transfer;
D O I
10.1016/S1359-4311(01)00126-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ice slurries can be used both for cold storage in place of chilled water or ice and as a secondary refrigerant since, up to certain concentrations, they can be pumped directly through distribution pipeworks and heat exchangers. For ice slurries to become more widely accepted, however, more engineering information is required on fluid flow and heat transfer characteristics. This paper reports on the results of experimental investigations into the melting heat transfer and pressure drop of 5% propylene/water ice slurry flowing in a commercial plate heat exchanger. Measurements were obtained for ice fractions between 0% and 25% by weight, and flow rates between 1.0 and 3.7 m(/)h. In this flow range, increasing the ice fractions from 0% to 20% caused around a 15% increase in the pressure drop over the flow range tested. The overall heat transfer coefficient, based on the logarithmic mean temperature difference, was found to remain fairly constant as the ice fraction increased from 5% to 20%. The heat transfer capacity of the heat exchanger was found to increase by more than 30% with melting ice slurry flow compared to chilled water flow. In a practical application, for a given thermal load this would lead to greater than 60% reduction in flow rate and pressure drop compared to chilled water cooling systems. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:721 / 732
页数:12
相关论文
共 50 条
  • [1] Pressure drop of flowing ice slurries in industrial heat exchangers
    Shire, G. S. F.
    Quarini, G. L.
    Evans, T. S.
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1500 - 1506
  • [2] Heat transfer and pressure drop in ice-water slurries
    Knodel, BD
    France, DM
    Choi, US
    Wambsganss, MW
    [J]. APPLIED THERMAL ENGINEERING, 2000, 20 (07) : 671 - 685
  • [3] HEAT TRANSFER AND PRESSURE DROP IN HEAT EXCHANGERS
    DONOHUE, DA
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1949, 41 (11): : 2499 - 2511
  • [4] Heat transfer and pressure drop correlations for finned plate ceramic heat exchangers
    Santomo Villanueva, Helio Henrique
    Batista de Mello, Paulo Eduardo
    [J]. ENERGY, 2015, 88 : 118 - 125
  • [5] Heat transfer and pressure drop properties of high viscous solutions in plate heat exchangers
    Warnakulasuriya, F. S. K.
    Worek, W. M.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (1-2) : 52 - 67
  • [6] A survey of correlations for heat transfer and pressure drop for evaporation and condensation in plate heat exchangers
    Eldeeb, Radia
    Aute, Vikrant
    Radermacher, Reinhard
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 65 : 12 - 26
  • [7] CFD Simulation of Heat Transfer and Pressure Drop in Compact Brazed Plate Heat Exchangers
    Gullapalli, Vijaya S.
    Sunden, Bengt
    [J]. HEAT TRANSFER ENGINEERING, 2014, 35 (04) : 358 - 366
  • [8] COMPARISON OF HEAT TRANSFER AND PRESSURE DROP CORRELATIONS FOR EVAPORATION OF ZEOTROPIC MIXTURES IN PLATE HEAT EXCHANGERS
    Mancini, Roberta
    Jensen, Jonas Kjaer
    Markussen, Wiebke Brix
    Elmegaard, Brian
    [J]. 13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 710 - 719
  • [9] Investigation of heat transfer and pressure drop in plate heat exchangers having different surface profiles
    Durmus, Aydin
    Benli, Hueseyin
    Kurtbas, Irfan
    Gul, Hasan
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (5-6) : 1451 - 1457
  • [10] A Numerical Analysis on the Heat Transfer and Pressure Drop Characteristics of Welding Type Plate Heat Exchangers
    Jeong, Jong Yun
    Nam, Sang Chul
    Kang, Yong Tae
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2008, 32 (09) : 676 - 682