In situ correction of mirror surface to reduce round-trip losses in Fabry-Perot cavities

被引:11
|
作者
Vajente, G. [1 ]
机构
[1] Ist Nazl Fis Nucl, Sez Pisa, I-56124 Pisa, Italy
基金
美国国家科学基金会;
关键词
MODEL;
D O I
10.1364/AO.53.001459
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High-finesse resonant cavities play an important role in many metrology applications such as gravitational wave detectors. The performance of these cavities can be limited by round-trip losses (RTP) generated by light that is scattered by the mirror surface defects into higher-order modes that are close to resonance. In this paper we develop a detailed model of this effect and we study possible strategies to correct the mirror surface. We show that it is possible to restrict the correction to the combination of a reduced set of surface deformations that can be reproduced on the mirror using projected heating patterns. We show with an optical simulation that by acting on the cavity mirrors it is possible to reduce RTP to the large angle scattering limit. We also show that the optimal correction can be computed without any a priori knowledge of the mirror surface, but based only on measurements of the power stored inside the cavity, thus opening up the possibility of a simple implementation of the proposed algorithm. (C) 2014 Optical Society of America
引用
收藏
页码:1459 / 1465
页数:7
相关论文
共 20 条
  • [2] EFFECT OF MIRROR MISALIGNMENT ON LOSSES IN A FABRY-PEROT RESONATOR
    VANYUKOV, MP
    ISAENKO, VI
    KALININ, VP
    LYUBIMOV, VV
    OPTICS AND SPECTROSCOPY-USSR, 1965, 19 (02): : 161 - &
  • [3] Correction to: Ultrathin Metasurface Wavelength-Selective Mirror for Millimeter/TerahertzWave Fabry-Perot Cavities
    Kebin Fan
    John Koulakis
    Karoly Holczer
    Seth Putterman
    Willie J. Padilla
    Journal of Infrared, Millimeter, and Terahertz Waves, 2020, 41 : 605 - 605
  • [4] In-situ measurement of mirror deformation using dual Fabry-Perot cavities for optical pressure standard
    Takei, Yoshinori
    Telada, Souichi
    Yoshida, Hajime
    Arai, Kenta
    Bitou, Youichi
    Kobata, Tokihiko
    MEASUREMENT, 2021, 173
  • [5] EFFECT OF MIRROR RIMS ON MODES AND LOSSES OF A PLANAR FABRY-PEROT RESONATOR
    CHECCACCI, PF
    CONSORTINI, A
    SCHEGGI, AM
    APPLIED OPTICS, 1971, 10 (06) : 1363 - +
  • [6] Polarization induced instabilities in external four-mirror Fabry-Perot cavities
    Zomer, Fabian
    Fedala, Yasmina
    Pavloff, Nicolas
    Soskov, Viktor
    Variola, Alessandro
    APPLIED OPTICS, 2009, 48 (35) : 6651 - 6661
  • [7] Fabry-Perot temperature dependence and surface-mounted optical cavities
    Fox, Richard W.
    PHOTONICS NORTH 2008, 2008, 7099
  • [8] An optical vernier technique for in situ measurement of the length of long Fabry-Perot cavities
    Rakhmanov, M
    Evans, M
    Yamamoto, H
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (03) : 190 - 194
  • [9] Ultrathin Metasurface Wavelength-Selective Mirror for Millimeter/Terahertz Wave Fabry-Perot Cavities
    Kebin Fan
    John Koulakis
    Karoly Holczer
    Seth Putterman
    Willie J. Padilla
    Journal of Infrared, Millimeter, and Terahertz Waves, 2020, 41 : 365 - 374
  • [10] Ultrathin Metasurface Wavelength-Selective Mirror for Millimeter/Terahertz Wave Fabry-Perot Cavities
    Fan, Kebin
    Koulakis, John
    Holczer, Karoly
    Putterman, Seth
    Padilla, Willie J.
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2022, 43 (9-10) : 844 - 844