Multifunctional stratified composite coatings by electrophoretic deposition and RF co-sputtering for orthopaedic implants

被引:18
|
作者
Nawaz, Qaisar [1 ]
Fastner, Steffen [1 ]
Rehman, Muhammad Atiq Ur [2 ]
Ferraris, Sara [3 ]
Perero, Sergio [3 ]
di Confiengo, G. Gautier [4 ]
Yavuz, Emre [5 ]
Ferraris, Monica [3 ]
Boccaccini, Aldo R. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Biomat, Dept Mat Sci & Engn, Cauerstr 6, D-91058 Erlangen, Germany
[2] Inst Space Technol Islamabad, Dept Mat Sci & Engn, Islamabad 44000, Pakistan
[3] Politecn Torino, Dept Appl Sci & Technol, Inst Mat Phys & Engn, I-10129 Turin, Italy
[4] Inst Sci & Technol Sustainable Energy & Mobil STE, Str Cacce 73, I-10135 Turin, Italy
[5] Univ Akdeniz Univ, Dept Chem, Inst Sci, TR-07058 Antalya, Turkey
关键词
BIOACTIVE GLASS NANOPARTICLES; TITANIUM; AG; MICROSTRUCTURE; DESIGN; LAYERS;
D O I
10.1007/s10853-020-05725-w
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, multifunctional stratified antibacterial and bioactive coatings were deposited and characterised. Initially, PEEK/bioactive glass (BG)/ mesoporous bioactive glass nanoparticle (MBGN) layers with a thickness of 110-120 mu m were deposited on stainless steel substrates using electrophoretic deposition (EPD). Thin silver nanocluster-silica composite layers with a thickness of 70-155 nm were then deposited by radio frequency (RF) co-sputtering on the previously deposited EPD coatings. The deposition was carried for two different sputtering times (20 min and 40 min), which led to different layer thicknesses. PEEK/BG/MBGNs coatings were also deposited via single-step EPD. A comparison between the physicomechanical and biological characteristics of single layer PEEK/BG/MBGNs composite coating and bilayer Ag-PEEK/BG/MBGNs is presented. Scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDX) indicated that silver nanoclusters were homogeneously distributed in the multilayered EPD/RF coatings. An apatite-like structure was formed on the surface of the coatings upon immersion in simulated body fluid (SBF) after 1 day. Silver nanoclusters embedded in the silica matrix as a top layer provided controlled release of silver ions which led to a potent antibacterial effect against E. coli and S. carnosus. Single layer coatings exhibited a burst release of Ag ions, which led to antibacterial effects but were toxic to osteoblast cells. Finally, the results of WST-8 assays confirmed that the multi-structured coatings allow osteoblast-like cells to proliferate and attach strongly on the surface of the coatings.
引用
收藏
页码:7920 / 7935
页数:16
相关论文
共 50 条
  • [1] Multifunctional stratified composite coatings by electrophoretic deposition and RF co-sputtering for orthopaedic implants
    Qaisar Nawaz
    Steffen Fastner
    Muhammad Atiq Ur Rehman
    Sara Ferraris
    Sergio Perero
    G. Gautier di Confiengo
    Emre Yavuz
    Monica Ferraris
    Aldo R. Boccaccini
    Journal of Materials Science, 2021, 56 : 7920 - 7935
  • [2] A study of TiAlN coatings prepared by rf co-sputtering
    Garcia-Gonzalez, L.
    Garnica-Romo, M. G.
    Hernandez-Torres, J.
    Espinoza-Beltran, F. J.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2007, 24 (02) : 249 - 257
  • [3] Electrophoretic Deposition of Gentamicin-Loaded Bioactive Glass/Chitosan Composite Coatings for Orthopaedic Implants
    Pishbin, Fatemehsadat
    Mourino, Viviana
    Flor, Sabrina
    Kreppel, Stefan
    Salih, Vehid
    Ryan, Mary P.
    Boccaccini, Aldo R.
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (11) : 8796 - 8806
  • [4] Wear Resistance of TiNx/CFy Coatings Deposited by RF Magnetron Co-Sputtering
    Zhu, Lin
    Wang, Jinwu
    Liu, Zhuang
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2015, 31 (12) : 1207 - 1216
  • [5] Wear Resistance of TiNx/CFy Coatings Deposited by RF Magnetron Co-Sputtering
    Lin Zhu
    Jinwu Wang
    Zhuang Liu
    Journal of Materials Science & Technology, 2015, 31 (12) : 1207 - 1216
  • [6] Electrophoretic deposition of zirconia-Bioglass® composite coatings for biomedical implants
    Radice, S.
    Kern, P.
    Buerki, G.
    Michler, J.
    Textor, M.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (02) : 436 - 444
  • [7] Antibacterial and Bioactive Coatings Based on Radio Frequency Co-Sputtering of Silver Nanocluster-Silica Coatings on PEEK/Bioactive Glass Layers Obtained by Electrophoretic Deposition
    Rehman, Muhammad Atiq Ur
    Ferraris, Sara
    Goldmann, Wolfgang H.
    Perero, Sergio
    Bastan, Fatih Erdem
    Nawaz, Qaisar
    di Confiengo, G. Gautier
    Ferraris, Monica
    Boccaccini, Aldo R.
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (38) : 32489 - 32497
  • [8] SiOx/TiOy/CzHt Composite Coatings Prepared by Magnetron Co-sputtering on Substrate Paper
    Liu, Zhuang
    Zhu, Lin
    Yang, Hanlin
    Chang, Jiang
    Cao, Wenping
    APPLIED SCIENCES IN GRAPHIC COMMUNICATION AND PACKAGING, 2018, 477 : 591 - 596
  • [9] Electrophoretic co-deposition of diamond/borosilicate glass composite coatings
    Wang, Y. H.
    Chen, Q. Z.
    Cho, J.
    Boccaccini, A. R.
    SURFACE & COATINGS TECHNOLOGY, 2007, 201 (18): : 7645 - 7651
  • [10] Electrophoretic deposition of chitosan/45S5 Bioglass® composite coatings for orthopaedic applications
    Pishbin, F.
    Simchi, A.
    Ryan, M. P.
    Boccaccini, A. R.
    SURFACE & COATINGS TECHNOLOGY, 2011, 205 (23-24): : 5260 - 5268