Performance of Composite Outdoor Insulator Under Superimposed Direct and Switching Impulse Voltages

被引:8
|
作者
Pinzan, Davide [1 ]
Branco, Fabio [2 ]
Haddad, Manu A. [1 ]
Slama, Mohammed El Amine [1 ]
Albano, Maurizio [1 ]
Waters, Ronald T. [1 ]
Leite, Helder [2 ]
机构
[1] Cardiff Univ, Adv High Voltage Engn Res Ctr, Cardiff CF10 3AT, Wales
[2] Univ Porto, High Voltage Lab, Dept Elect & Comp Engn, P-4099002 Porto, Portugal
基金
欧盟地平线“2020”;
关键词
Insulators; Conductivity; Flashover; Rain; Switches; Voltage measurement; Standards; Insulator; HVDC; Switching Impulse; Superimposition;
D O I
10.1109/TPWRD.2020.3003980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High Voltage Direct Current (HVDC) systems are increasingly being adopted around the world to integrate renewable resources, increase power transfer, and allow flexible grid operation. HVDC overhead lines play a critical role in this, and focus is needed on the research of composite outdoor insulators failure. In the case of a pole to ground fault of a bipolar scheme, the healthy pole experiences a slow transient overvoltage similar to a Switching Impulse (SI) superimposed on the operational DC voltage. However, there is no standard test for such voltage superimposition. This paper investigates the performance of a composite insulator stressed with such superimposition under dry and rain conditions. To determine the direct voltage influence on the flashover voltage, the results have been compared with the SI only case. Four different rain conductivities have been used in the test program because these insulators can be exposed to different acid conductive rain types, typical of industrialized environments. Both vertical and horizontal orientations have been studied. It was possible to conclude that, in most cases, the direct voltage pre-energization has a negative impact on the flashover performance. The increase in rain conductivity leads to lower flashover values, and the horizontal orientation outperforms the vertical configuration. Under these test conditions, the flashover voltages were all larger than a typical DC operational switching surge. Thus, in the case of pole to ground fault, the healthy pole failure risk appears to be low. However, further research is needed on higher voltages and polluted conditions.
引用
收藏
页码:1193 / 1201
页数:9
相关论文
共 50 条
  • [1] Sparkover behavior of insulator under composite switching impulse/alternating or direct voltage
    Wang, LM
    Yin, Y
    Guan, ZC
    Liang, XD
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 225 - 227
  • [2] The Accumulation Characteristic of Surface Charges on GIS Insulator under Switching Impulse Voltages in SF6
    Qi, Bo
    Gao, Chunjia
    Li, Chengrong
    Zhao, Linjie
    Sun, Xiaqing
    Lei, Yuanyuan
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 130 - 133
  • [3] Switching impulse flashover performance of 110 kV composite insulator covered-with ice
    Jiang, Xing-Liang
    Sheng, Dao-Wei
    Yuan, Ji-He
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (04): : 772 - 776
  • [4] Corona characteristics of aerial conductors under switching impulse voltages
    Sun, Ying
    Montenegro, Alejandro
    Tobin, Tom
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (01) : 206 - 213
  • [5] BREAKDOWN IN SULPHUR HEXAFLUORIDE AND NITROGEN UNDER DIRECT AND IMPULSE VOLTAGES
    BINNS, DF
    HOOD, RJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1969, 116 (11): : 1962 - &
  • [6] BREAKDOWN IN SULPHUR HEXAFLUORIDE AND NITROGEN UNDER DIRECT AND IMPULSE VOLTAGES
    RADWAN, RM
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1970, 117 (05): : 1055 - &
  • [7] Surface Flashover Induced by Metal Contaminants Adhered to Tri-Post Epoxy Insulators under Superimposed Direct and Lightning Impulse Voltages
    Hu, Qi
    Li, Qingmin
    Liu, Zhipeng
    Xue, Naifan
    Ren, Hanwen
    Haddad, Manu
    POLYMERS, 2022, 14 (07)
  • [8] BREAKDOWN IN SULPHUR HEXAFLUORIDE AND NITROGEN UNDER DIRECT AND IMPULSE VOLTAGES - REPLY
    BINNS, DF
    HOOD, RJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1970, 117 (05): : 1056 - &
  • [9] Effect of humidity on the breakdown of air gaps under oscillatory switching impulse voltages
    Bharadwaj, RM
    Prabhakar, BR
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 320 - 323
  • [10] Attachment Processes and Influencing Factors in Competition Tests Under Switching Impulse Voltages
    Xie, Shijun
    D'Alessandro, Franco
    Chen, Weijiang
    He, Junjia
    He, Hengxin
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2013, 41 (07) : 1773 - 1780