Standards for device implantation and follow-up: personnel, equipment, and facilities: results of the European Heart Rhythm Association Survey

被引:11
|
作者
Todd, Derick [1 ]
Bongiorni, Maria Grazia [2 ]
Hernandez-Madrid, Antonio [3 ]
Dagres, Nikolaos [4 ]
Sciaraffia, Elena [5 ]
Blomstrom-Lundqvist, Carina [5 ]
机构
[1] Liverpool Heart & Chest Hosp, Inst Cardiovasc Med & Sci, Liverpool L14 3PE, Merseyside, England
[2] Univ Hosp Pisa, Cardiol Dept 2, I-56100 Pisa, Italy
[3] Alcala Univ, Hosp Ramon y Cajal, Dept Cardiol, Madrid 28034, Spain
[4] Univ Athens, Attikon Univ Hosp, Cardiol Dept 2, Athens 12462, Greece
[5] Uppsala Univ, Dept Cardiol, Inst Med Sci, S-75185 Uppsala, Sweden
来源
EUROPACE | 2014年 / 16卷 / 08期
关键词
Pacemaker; Implantable cardiac defibrillator; Personnel; Equipment; Facilities; EHRA survey; EP wire; ANTICOAGULATION; THERAPY;
D O I
10.1093/europace/euu209
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac device implantation is the most common of all invasive cardiac electrophysiological procedures. Over 250 000 devices are implanted each year in Europe. The purpose of this European Heart Rhythm Association (EHRA) survey was to assess the facilities, personnel, and protocols of members of the EHRA electrophysiology (EP) research network involved in device implantation. There were 68 responses to the questionnaire. The survey responses were mainly (84%) from medium- to high-volume device implanting centres, performing > 200 implants per year, with over 50% performing > 400 implants per year. Most consultants are male (85%), half of all centres had no female consultants, and only one in six had more than one female consultant. There is trend towards specialization in device implantation. The combination of device implantation and EP is still common (76% of all centres) but only 34% of centres have consultants performing device implantation and coronary intervention. Moreover, 23% of centres have all device implantation performed by consultants who do not perform any other types of procedure. Cardiac device implantation as a day case is the planned admission for routine elective device implantation in 30% of hospitals, 47% of hospitals have a single night stay, and 23% of hospitals have admission durations of two or more nights. Device implantation is available as a 24 h service, 365 days a year in 38% of hospitals. The commonest other model was as a daytime service on weekdays in 45% of hospitals.
引用
收藏
页码:1236 / 1239
页数:4
相关论文
共 50 条
  • [1] Practices of cardiac implantable electronic device follow-up: results of the European Heart Rhythm Association survey
    Marinskis, Germanas
    van Erven, Lieselot
    Bongiorni, Maria Grazia
    Lip, Gregory Y. H.
    Pison, Laurent
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2012, 14 (03): : 423 - 425
  • [2] Personnel, equipment, and facilities for electrophysiological and catheter ablation procedures in Europe: results of the European Heart Rhythm Association Survey
    Estner, Heidi L.
    Chen, Jian
    Potpara, Tatjana
    Proclemer, Alessandro
    Todd, Derick
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2014, 16 (07): : 1078 - 1082
  • [3] Healthcare personnel resource burden related to in-clinic follow-up of cardiovascular implantable electronic devices: a European Heart Rhythm Association and Eucomed joint survey
    Boriani, Giuseppe
    Auricchio, Angelo
    Klersy, Catherine
    Kirchhof, Paulus
    Brugada, Josep
    Morgan, John
    Vardas, Panos
    [J]. EUROPACE, 2011, 13 (08): : 1166 - 1173
  • [4] Implantation of subcutaneous implantable cardioverter defibrillators in Europe: results of the European Heart Rhythm Association survey
    Boveda, Serge
    Lenarczyk, Radoslaw
    Haugaa, Kristina
    Fumagalli, Stefano
    Hernandez Madrid, Antonio
    Defaye, Pascal
    Broadhurst, Paul
    Dagres, Nikolaos
    [J]. EUROPACE, 2016, 18 (09): : 1434 - 1439
  • [5] British Heart Rhythm Society Standards for Implantation and Follow-up of Cardiac Rhythm Management Devices in Adults: January 2024 Update
    Foley, Paul
    Thomas, Honey
    Dayer, Mark
    Robinson, Sophie
    Ezzatt, Vivienne
    Swift, Matthew
    Johal, Nadiya
    Roberts, Eleri
    [J]. ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2024, 13
  • [6] Imaging techniques in electrophysiology and implantable device procedures: results of the European Heart Rhythm Association survey
    Pison, Laurent
    Proclemer, Alessandro
    Bongiorni, Maria Grazia
    Marinskis, Germanas
    Hernandez-Madrid, Antonio
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2013, 15 (09): : 1333 - 1336
  • [7] X-ray exposure hazards for physicians performing ablation procedures and device implantation: results of the European Heart Rhythm Association survey
    Marinskis, Germanas
    Bongiorni, Maria Grazia
    Dagres, Nikolaos
    Lewalter, Thorsten
    Pison, Laurent
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2013, 15 (03): : 444 - 446
  • [8] Defibrillation testing at the time of implantable cardioverter defibrillator implantation: results of the European Heart Rhythm Association survey
    Morgan, John M.
    Marinskis, Germanas
    [J]. EUROPACE, 2011, 13 (04): : 581 - 582
  • [9] Do cardiologists follow the European guidelines for cardiac pacing and resynchronization therapy? Results of the European Heart Rhythm Association survey
    Sciaraffia, Elena
    Dagres, Nikolaus
    Hernandez-Madrid, Antonio
    Proclemer, Alessandro
    Todd, Derick
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2015, 17 (01): : 148 - 151
  • [10] Work-up and management of lone atrial fibrillation: results of the European Heart Rhythm Association Survey
    Pison, Laurent
    Hocini, Meleze
    Potpara, Tatjana S.
    Todd, Derick
    Chen, Jian
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2014, 16 (10): : 1521 - 1523